THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL. 20 mbar 3 - TECHNICAL DATA Model Description Dimensions in mm. (LxDxH) Area plate MB7FT4GL Smooth plate gas Fry Top 400 x 700 x 270 0,165 dm 51BS3544 MB7FT4GR Grooved plate gas Fry Top...
4 - INSTALLATION INSTRUCTIONS 4.1 Safety rules 4.3.3 Installation Before installation, gas connection, power check, conversion or • Installation, modifications and maintenance of the appliance adjustment and start up ask for gas supply company advice. must be carried out by authorised personnel in compliance with current safety standards.
5 - SET-UP FOR OPERATION 5.1 Preparation and Start-up If you wish to further check the nominal power, you may do so by using a gas meter according to the so-called "volumetric method". A simple inspection is usually enough to check if injectors are func- Before starting up the appliance, remove the protective wrapping.
Page 8
5 - SET-UP FOR OPERATION 5.1.5 Power check for operation with liquid gas 5.1.9 Conversion and adjustment Check if the type of injectors used meet the data of the table 1. To change over form one kind of gas to another, for example from methane to liquid gas, or to another type of gas, the use of suitable Check that the pressure reducer installed in the system has an outlet injectors for the main burner is required, in accordance with the...
5 - SET-UP FOR OPERATION After fitting the new injectors, reset primary air distance “A” (fig. 5.3.5 Burner fry top 600 2B) see table 1, and fasten the bushing with the appropriate screw.. Unscrew the screws (pos. 2 and 5 fig. 2B) fixing the burner to the After the replacement check the seal using a leack detector spray.
6 - ISTRUZIONI PER L’USO 6.1 Safety, cleaning and repair rules Special precautions It is recommanded to keep cleaning the plate during use, • This appliance is used for the preparation of meals at industri- using a scraper or a dampf cloth to remove particles of food al level.
Page 11
6 - ISTRUZIONI PER L’USO • 1.4016 or 1.4511 = magnetizable chromed steels 6.6.3 The 2002/96/EC (WEEE) Directive: • 1.4301, 1.4401 and 1.4571 = non-magnetizable chromed steels information to users Chromed steels have favourable thermo-technical characteristics. In This informational note is meant only for Fig.
Page 12
WARNING THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS BOOKLET DUE TO COPYING OR PRINTING ERRORS. DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPROVEMENT, THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY. THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THE INSTRUCTIONS CONTAINED IN THIS MANUAL ARE NOT OBSERVED.