Advertisement

Quick Links

Reef Master CMK
User Manual
A1 2023-11-27
Kamoer Fluid Tech(Shanghai) Co.,Ltd.
www.kamoer.com

Advertisement

Table of Contents
loading

Summary of Contents for Kamoer Reef Master CMK

  • Page 1 Reef Master CMK User Manual A1 2023-11-27 Kamoer Fluid Tech(Shanghai) Co.,Ltd. www.kamoer.com...
  • Page 2: Reading Tips

    1. Reef Master CMK User Manual 2. Reef Master CMK Quick Start Guide It is recommended that users first read the "Reef Master CMK Quick Start Guide" to understand the usage process. Please read the "Reef Master CMK User Manual" for detailed product information.
  • Page 3: Safety Instructions

    Apple users enter the App Store, while Android users enter Google Play and search for 'Kamoer Remote'. Find the application download corresponding to the icon. Kamoer Remote App supports Android 4.4 and above systems, and iOS 9.1 and above systems.
  • Page 4: Get Tutorials

    Get Tutorials After installing the app, open it and click the "?" button in the upper right corner of the device page to enter the tutorial page. Click to enter the corresponding device model, including user manual and frequently asked questions.
  • Page 5: Table Of Contents

    Catalog Reading Tips ..............................1 Symbol Description ..........................1 Usage Suggestions ..........................1 Safety Instructions..........................2 Download Kamoer Remote App ......................2 Get Tutorials............................3 Catalog ................................. 4 Product Overview ............................7 Introduction ............................7 Functional Highlights ......................... 7 Application Occasions ........................8 Unpacking Preparation ........................
  • Page 6 Manual Detection ..........................19 Automatic Detection ........................20 Retest Function ..........................22 View History ............................23 System Settings ..........................25 Linkage Function ..........................26 Introduction to Linkage Function ................... 26 Device Binding .......................... 28 Use of Titration Equipment ..................... 30 Use of Calcium Reactor Equipment ..................
  • Page 7 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Product Overview This chapter mainly introduces the characteristics, application scenarios, and unboxing instructions of Reef Master CMK.
  • Page 8: Product Overview

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Product Overview Introduction Reef Master is an automated equipment for testing water quality in aquatic environments. The Reef Master CMK Bone Master can test three parameters: calcium, magnesium, and KH. In addition to testing calcium, magnesium, and KH, the Reef Master SPA Sea God can also test parameters such as nitrite, nitrate, and phosphate.
  • Page 9: Application Occasions

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual The F4 PRO titration pump and calcium reactor can be linked and controlled to achieve  automatic adjustment of water quality parameters Application Occasions Marine organism feeding: including hard coral (SPS), soft coral (LPS), and mixed coral ...
  • Page 10: Component Name

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual 1. Reef Master CMK Host 2. Power adapter 3. 2 meters of sea drainage pipe 4. Detection reagent tube, 3-section 1-meter tube 5. Reagent bottle cap with hard tube and connector 6.
  • Page 11: Display Screen Status Description

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Display Screen Status Description Working mode: Display the working mode, and the device supports automatic and manual modes WiFi connection status: indicates in the distribution network, indicates successful distribution network, indicates network connection failure, and...
  • Page 12 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Time of Latest Detection Value: The time of detecting the latest parameter, which is a type of calcium, magnesium, and KH Time of Next Test Value: The planned time of the next test parameter, which is a type of...
  • Page 13 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual First Use This chapter mainly introduces how to check and confirm the normal operation of various functions of the equipment after assembly for the first time.
  • Page 14: First Use

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual First Use Product Installation Reagent bottle installation: Remove the original reagent bottle cap...
  • Page 15 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual APP Operation This chapter mainly introduces how to use the app to operate Reef Master CMK.
  • Page 16: App Operation

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual APP Operation Distribution Network Equipment The app requires a network connection to set and read device parameters, so the device configuration needs to be connected to the network. On the homepage of the device list, click the add button in the upper right corner to enter the device's distribution interface.
  • Page 17: Overview Of App Interface Module

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual a. To configure a device to connect to Wi Fi, you only need to configure it once. After successful configuration, as long as the app can connect to the network, you can find the device in the device list by opening the app.
  • Page 18: Status Interface Function

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Status Interface Function a. Keep Value Balance (Extended Functionality - Under Development): By detecting calcium, magnesium, and KH values through the device, automatically adjust the F4 Pro titration pump or calcium...
  • Page 19: Reagent Bottle Remaining Quantity Setting

    Reagents will decrease with use, and they need to be replenished when the trial dose is insufficient. After receiving the new reagent, scan the QR code on the reagent bottle through the Kamoer Remote App, and set the reagent capacity based on the QR code to update the capacity of the...
  • Page 20: Manual Detection

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual a. Click on the reagent bottle status to enter the remaining quantity modification interface b. If it is necessary to increase the remaining amount of reagent bottles, it is necessary to purchase reagents.
  • Page 21: Automatic Detection

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual e. Test Settings; Here, you can set detection related parameters, such as the re detection function and the automatic cleaning reaction chamber function Automatic Detection a. Click to switch between automatic/manual detection modes b....
  • Page 22 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual f. Test Settings, where you can set detection related parameters g. Week label, click to select the week label, and the corresponding time plan for that day will be displayed below, with black representing selected h....
  • Page 23: Retest Function

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Retest Function The principle of the retest function is that when there is a significant difference between the latest detection value and the previous detection value within a certain period of time, a retest is automatically performed to determine whether the detection value is truly abnormal.
  • Page 24: View History

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual calcium setting triggers a retest with a difference of 50ppm, the calcium concentration detected last time was 450ppm. If the calcium concentration detected this time is less than 400ppm or greater than 500ppm, the retest function will be triggered e....
  • Page 25 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual a. Click on the icon Detail on the status page to enter the view history details page b. Click to switch the parameters of the history to be viewed c. The visible period of historical records, divided by the length of weeks and months d....
  • Page 26: System Settings

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual System Settings a. Firmware version information display b. Name; Click to modify the device name, which will be displayed on the APP homepage c. Serial number; Equipment serial number information, each device has a unique serial number d....
  • Page 27: Linkage Function

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual synchronize the time through the network; Accurate timing is essential for planning to be executed correctly i. Factory Settings Reset: Restore parameters to factory settings j. Remove Device: Unbind App and device...
  • Page 28 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Reef Master linked calcium reactor pump...
  • Page 29: Device Binding

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual a. On the status homepage, click “Keep Value Balance” to enable the function, and then enter the linkage parameter setting interface; b. Maintain a stable value switch. When this switch is turned on, the linkage control function takes effect.
  • Page 30 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual a. Adjusting water quality parameters through a titration pump b. The function switch for adjusting water quality parameters through titration; When the switch is turned on, the titration adjustment parameters take effect c....
  • Page 31: Use Of Titration Equipment

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Use of Titration Equipment a. Added titration equipment, click to set parameters b. Click to add a new titration device. To add a new titration device, first bind it to the App, then...
  • Page 32: Use Of Calcium Reactor Equipment

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual h. Range ; For safety reasons, automatic adjustment parameters will take effect within this parameter range. Once the Reef Master detects a parameter that exceeds this range, automatic adjustment will not take effect i....
  • Page 33 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual a. Run for a period of time; This setting is achieved through the wired connection of KH Carer E1. It was detected that the KH was low, and the calcium reactor pump was controlled to run for a period of time b....
  • Page 34 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual e. The operating scenario of the calcium reverse pump created; The usage method is achieved through Reef Master and calcium reactor pump via wireless server f. Switch for scene control; Scene operation takes effect when the switch is turned on g....
  • Page 35: Maintenance Function

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Maintenance Function The maintenance module includes pump maintenance, magnetic stirring maintenance, clamp valve maintenance, peristaltic pump operation, liquid filling and discharge, calibration, optical path inspection, etc., which can facilitate the maintenance of the Reef Master.
  • Page 36 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual a. Fill Tubes: In this module, you can fill the pump tube b. Running pumps: In this module, you can run clamp valves, pumps, magnetic stirring, etc c. Test value correct: The measurement results can be calibrated here, and the principle of calibration is to use standard solution to calibrate the measurement results of Reef Master.
  • Page 37: Running And Stirring

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Running and Stirring In the Running Pumps function, the reaction chamber can be emptied, and the stirring force of magnetic stirring can also be set. a. Empty all liquids in the tube, click to enter the empty liquid guide page b....
  • Page 38: Empty All Pipelines

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Empty All Pipelines When the equipment is not in use or is being transported, it is necessary to empty the liquid in the equipment pipelines and the connecting pipes outside the equipment to prevent the overflow of liquid in the equipment pipelines from affecting transportation or storage a....
  • Page 39: Test Value Correct

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual b. Click to clear all pipelines. Here, the liquid in the built-in pipelines and colorimetric dishes on the device is cleared. The waste liquid generated by clearing the pipelines is discharged from...
  • Page 40 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual a. Click to enter the detection value correction process, select the parameters that need to be calibrated, and then go to correct b. Previously detected detection values c. Input actual detection value...
  • Page 41: Time Setting

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Time Setting When the time of the device does not match the local time, the real-time clock time of the device can be synchronized through the app to ensure the normal execution of the device titration plan.
  • Page 42 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Equipment Maintenance...
  • Page 43: Equipment Maintenance

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Equipment Maintenance Magnetic Stirring When encountering the problem of abnormal noise in magnetic stirring, when troubleshooting, first remove the front cover b of the Reef Master shown in the figure below. Go to System Settings ->Maintain ->Running Pumps to enter the control interface for Running and Stirring.
  • Page 44 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Attention: The reaction chamber includes a magnetic stirrer, which operates during water quality parameter testing; When there is abnormal noise in magnetic stirring, it is possible that the magnetic stirring force has changed. The problem can be solved by setting different magnetic stirring forces on the App;...
  • Page 45 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Appendix...
  • Page 46: Appendix

    Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual Appendix Technical Parameters Size(L x W x H) 230 x 120 x 338 mm Weight Approximately 2547 g (excluding power adapter) Input: 100VAC -240VAC Power Output: DC24V 2A Interface WIFI, Bluetooth, CAN (backup) Working environment Temperature 0-70 ℃, humidity 10% -90% (non condensing)
  • Page 47 Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual 3. Non warranty coverage The following factors are not covered by the free warranty, and customers are required to pay for repairs. 1) Product appearance (please confirm at the time of purchase);...
  • Page 48 Addr: Building 4, No. 79 XiangJing Road, Songjiang District, Shanghai, China Phone: +86-021-67742578 Website: www.kamoer.com Kamoer is a registered trademark of Kamoer Fluid Tech (Shanghai) Co., Ltd. The company reserves the right to improve and change product appearance and technical specifications without prior notice.

Table of Contents