  • Page 1 AQUWA 12 GAS FUELED HERMETIC WATER HEATER USER MANUAL...
  • Page 2 AquWa 12...
  • Page 3: Table Of Contents

    CONTENTS DEAR WARMHAUS CUSTOMER ........................4 1.1. GENERAL WARNINGS .............................4 1.2. GENERAL WARRANTY CONDITIONS ........................4 1.3. SAFETY INSTRUCTIONS ............................5 1.3.1. Installation and Service ................................5 1.3.2. Gas Leakages ....................................5 1.3.3. Waste Gas (Flue) Leakages ..............................6 1.3.4. Combustion Air; ..................................6 1.3.5. Inspection and Maintenance; ..............................6 1.3.6.
  • Page 4: Dear Warmhaus Customer

    Manufacturer: Warmhaus Isıtma ve Soğutma Sistemleri Tic. A.Ş. Bursa Organize Sanayi Bölgesi Park Cad. No:10 16140 Nilüfer-Bursa / Turkey WARMHAUS 1015 21 WARMHAUS A.Ş. reserves the right to make all kinds of technical and commercial changes without notice and disclaims all liabilities for printing and spelling errors. warmhaus.com...
  • Page 5: Safety Instructions

    Read the entire manual before the installation and follow the instructions. measures when soldering and brazing flammable and combustible Have the water heater checked by an authorized Warmhaus service materials. technician at least once a year. Failure to follow these instructions may result •...
  • Page 6: Waste Gas (Flue) Leakages

    • Maintenance and repairs may be carried out only by a trained and certified be up to 60 °C depending on the settings of the water heater and the hot Warmhaus service. season conditions. • Correct any installation errors immediately to avoid damage to the system.
  • Page 7 warmhaus.com...
  • Page 8: User Section

    Call the gas company or the Authorized Service. (See 1.1. General Warnings and 1.3.2. Gas Leakages) Initial start-up of your water heater should be performed by Warmhaus Authorized Service for your safety and to maintain the warranty of your water heater.
  • Page 9: Water Heater Standby Position

    2.3.4. Function of Operation with Solar Energy Systems with Storage 2.3. SAFETY FUNCTIONS If the Aquwa 12 water heater is used with a solar energy system with storage, this function is activated by the authorized service and the necessary function There are many safety functions for safe use of your water heater, and due to settings are made.
  • Page 10: Solutions For Malfunctions And Errors

    1-) Reset / restart the device. E 37 At low voltage and E37 malfunction code mode OR <182 VAC 2-) If the malfunction persists, call the Authorized Service. is flashing on the screen +/- 5% in automatic calibration mode warmhaus.com...
  • Page 11 Device is not functioning Gas valve connection Broken wiring 1-) Reset / restart the device. E 88 and E88 malfunction code error Gas valve malfunction 2-) If the malfunction persists, call the Authorized Service. is flashing on the screen warmhaus.com...
  • Page 12: Technical Data

    3. TECHNICAL DATA TECHNICAL DATA UNIT WARMHAUS AquWa 12 Gas type Gas Supply Pressure mbar Gas Category 2E(S) I2E3P I2E(S)3P I2H3P I2E+3P Rated Heat Load (Minimum) 10.0 Rated Heat Load (Maximum) 23.5 23.5 Rated Heat Power (Minimum) 8.90 8.95 Rated Heat Power (Maximum) 20.7...
  • Page 13 warmhaus.com...
  • Page 15 All descriptions and illustrations provided in this document have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request.