Use and maintenance manual for rotary level indicator series PFG05L & PFG57L
PRODUCT IDENTIFICATION
The PFG05L and PFG57L series instruments are rotary level indicators for granular solids. The identification of the device is
accomplished by the specific label outside the casing, whose characteristics are shown below:
1
2
3
4
8
Tampering with the label entails the loss of validity of the product certifications.
Ex MARKING DETAILS
II 3 D
Ex
tc
INSTALLATION
The device can be installed in any position. In case of an horizontal or titled
installation, mount the device with the cable entrance on the right side for
PFG05L models, or lower side for PFG57L models. The coupling of the
instrument with the wall of the container (silos) can be either threaded or
anged; images 2 and 3 show the standard couplings. Always refer to the
technical drawings supplied by the Manufacturer together with this manual.
Protect the device from falling material or excessive weight, using protective
deectors. For cable entries, 1 (one) or 2 (two) G 1/2 threaded holes (BSPP) are
available. Seal the cable entries with cable glands or sealing caps suitable for
the operating range shown on the label.
The protective caps supplied with the device are only for protection during
transport and storage, they are not suitable for the use of the instrument and it is
responsibility of the installer to replace them.
The diameter of the power supply cable must correspond to the tightening range indicated by the cable gland used.
Use and maintenance manual for rotary level indicator series PFG05 & PFG57
Via dell'Industria 12 - 12/A - 42025 CAVRIAGO - RE - Italy
R
CF/PI/Iscr.Reg.Imprese RE 00303000350
VAT IT00303000350 REA 90637
Telefono/Phone +390522942641 / +390522941172
www.camlogic.it - email: camlogic@camlogic.it
IIIB
T**
Dc
ATEX MARKING (2014/34/EU / S.I. 2016 No. 1107 )
European community marking for equipment intended for use in areas under risk of
explosion.
Group II equipment intended for use in surface industry.
Category 3 equipment, suitable for use in areas classified Zone 22.
Combustible dusts; combusible substance present in the area of installation and the
internal volume.
Ex symbol.
Protection method Ex t - protection from the ignition of combustible dusts from enclosure.
For combustible dusts type IIIB (suitable for use with any kind of dust).
Temperature class (maximum surface temperature the device can reach):
T85°C = standard version
T200°C = high temperature versions (PFG-*.../AT)
EPL (Equipment Protection Level) - Protection level Dc = increased, which is not a source of
ignition during normal operation.
1. Production year of the instrument
6
2. Manufacturer data
3. Product model and electrical rating
4. Warnings
5. Ambient temperature range:
-20°C ÷ +70°C (standard application, all models)
-40°C ÷ +70°C (low temperature applications, models PFG*...BL)
Maximum process temperature:
+70°C (standard applications)
5
+200°C (high temperature applications, models PFG*...ATL)
6. Conformities and Notied Body number
7. Serial number
7
8. Ex marking
0601_002_0_rev2 - 10.2022
I
.1
MG
Page 1 of 4

Advertisement

loading

Summary of Contents for Camlogic PFG05L Series

  • Page 1 Via dell'Industria 12 - 12/A - 42025 CAVRIAGO - RE - Italy CF/PI/Iscr.Reg.Imprese RE 00303000350 VAT IT00303000350 REA 90637 Telefono/Phone +390522942641 / +390522941172 www.camlogic.it - email: camlogic@camlogic.it S.a.s. di Guazzetti Giovanni & C. COSTRUZIONI MECCANICHE ELETTRICHE Use and maintenance manual for rotary level indicator series PFG05L & PFG57L PRODUCT IDENTIFICATION The PFG05L and PFG57L series instruments are rotary level indicators for granular solids.
  • Page 2 6x ø7,5 PFG57L PFG05L 4x ø7 G 1" 1/2 (BSPP) G 2" 1/2 (BSPP) ELECTRICAL CONNECTION The entire connection of the device must take place while the device is de-energized. The earthing connection (by means of an M5x8 screw and a notched stainless-steel washer) must take place before any other connection is established.
  • Page 3 Maintenance must be carried out in compliance with IEC 60079-17 / BS EN 60079-17 standards. CAMLogic level indicators need no routine maintenance, however it is advisable to carry out the following checks: at each opening of the cover or removal of the instrument, visually check the sealing gaskets present.
  • Page 4 WARRANTY CAMLogic, in addition to the terms of the supply contract, guarantees its products for a period of twenty-four (24) months from the date of shipment. This warranty is expressed only in the repair or replacement free of charge of parts that, after careful examination by the Manufacturer, turn out to be defective.