6.5.3. START-UP
Follow the start-up procedure in cold or hot depending
on the condition of your engine.
6.5.3.1. STARTING THE MOTOR IN COLD
• Place the machine on a flat, stable surface to start it.
• Place the circuit breaker in alternating current (AC)
in the OFF position.
• Place the faucet of the fuel in the open position
(ON).
• Place the choke in closed air position
• Set the switch of the motor to the on position (ON).
• Hold the machine by casting so it doesn't move
from its position on the floor when pulling the
starter rope.
• Pull the starter rope until the engine starts.
• If the machine starts and doesn't stop gradually
changing the air level position
• Let the engine warm up for a few minutes before
using the machine.
6.5.3.2. STARTING THE MOTOR HOT
• Place the machine on a flat, stable surface to start.
• Place the circuit breaker in alternating current (AC)
in the OFF position.
• Place the fuel tap in the open position (ON).
• Place the choke in the normal working position
(open position RUN).
• Set the switch of the motor in position (ON).
• Hold the machine by the handle so it doesn't move
• Pull the starter rope until the engine starts.
• If after a few attempts the machine does not start
6.5.4. STOPPING THE MOTOR
• Stop the engine by moving the engine switch to the
• Place the tap of the fuel in the closed position
7. USING THE MACHINE
it is designed. The use of this machine for any other
use is dangerous and can cause harm to the user
and/or the machine.
(CHOKE).
and chemically dangerous substances.
In case of a concentration of gases produced by poor
(air open RUN).
ventilation, remove everything that impedes the flow
of clean air from the work area to improve ventilation
and do not return to work in the area unless you have
properly ventilated it and are sure that ventilation is
sufficient so that this concentration does not happen
again.
Do not use this machine when you are tired or under
the influence of drugs, alcohol or medication. A
moment of distraction while you are operating the
machine could cause serious personal injury.
37/120
from its position on the floor when pulling the
starter rope.
follow the steps in the engine starting.
OFF position.
(OFF).
Use this machine only for the purposes for which
Do not start the machine in a room or
enclosure. The exhaust gases, fumes from
the fuel and oil contain carbon monoxide
English