  • Page 1 Operating instructions for: BioMant-ONE Weed control machine MANUFACTURER: Mantis ULV Vierlander Straße 11a 21502 Geesthacht Phone: +49 (0) 4152 8459-0 February 2020 www.mantis-ulv.com...
  • Page 2: Table Of Contents

    Installation on a vehicle ..................... 15 Assembly ..........................15 Electrical Equipment ......................15 Fuel supply .......................... 15 Measures prior to commissioning ..................16 Commissioning, test run and working operation ..............17 Commissioning ........................17 Mantis ULV Sprühgeräte GmbH Page 2 of 29...
  • Page 3 Disassembly ........................25 Transport ..........................25 Storage ..........................25 Disposal ..........................26 Annexes ..........................27 10.1 EC- Declaration of Conformity ..................27 10.2 Schematic diagram ......................28 10.3 Spare parts list ........................29 Mantis ULV Sprühgeräte GmbH Page 3 of 29...
  • Page 4: Foreword

    For further information about use and maintenance of the machine which is not included in these Operating Instructions, please contact the manufacturer. Despite all continuous efforts of the Mantis ULV Sprühgeräte GmbH to further improve this product on all levels (especially in the area of safety), unforeseeable circumstances cannot be prevented. If, for this reason, unsafe situations should occur, then immediately contact the manufacturer.
  • Page 5: Introduction

    In this case, the manufacturer shall not be liable for the reuse of the whole system or parts of it, because several process conditions influence the safety of the process. With this, they also affect the safety of the system. Mantis ULV Sprühgeräte GmbH Page 5 of 29...
  • Page 6: Description Of The Weed Control Machine Biomant One

    Frame structure of stainless steel Electrical pump Temperature control for constant with storage battery or 230 V output water temperature power supply Sleeves for forklift truck forks Maintenance-free battery pack (optional) Fig.1: Main overview Mantis ULV Sprühgeräte GmbH Page 6 of 29...
  • Page 7: Functional Principle Of The Weed Control Machine Biomant One

    An unobstructed work area needs to be provided for the operation of the BioMant One weed control machine. Remove all risks of impact and tripping. Keep order and cleanliness in the work area to exclude risks of impact and tripping. Mantis ULV Sprühgeräte GmbH Page 7 of 29...
  • Page 8: Technical Specifications

    This section contains the technical data of the machine. 2.4.1. Technical data Machine Weed control machine BioMant One Manufacturer Mantis ULV Sprühgeräte GmbH Year of manufacturing Refer to type plate Serial-No. Refer to type plate Hot water heater Diesel- or LPG burner...
  • Page 9: Operating Regulations

    If it is not used as intended, this cannot only endanger the operator or persons nearby, but also cause damages on the machine. The usage of the machine other than specified without the explicit authorisation of the manufacturer is not allowed. Mantis ULV Sprühgeräte GmbH Page 9 of 29...
  • Page 10: Safety Instructions

    Despite of the splash-proof design of the machine pay attention to the live components nearby the machine. They can cause electrocution or damage the machine. Be careful, when you open the coverings. If the covering is open, sharp moving parts can still move. Mantis ULV Sprühgeräte GmbH Page 10 of 29...
  • Page 11 While the battery is being charged it is not allowed to switch on the BioMant or refill the fuel tank. For all questions on function or components, please contact your dealer or the manufacturer. Mantis ULV Sprühgeräte GmbH Page 11 of 29...
  • Page 12: Pictograms

    It is not allowed to open the hood and the doors during operation. Fig.4: Doors and hood of the machine Take care when opening the hood and the doors because the components in the machine can be hot. Mantis ULV Sprühgeräte GmbH Page 12 of 29...
  • Page 13: Control Panel

    In an emergency, the machine must be able to be switched off immediately. For this purpose, the weed control machine BioMant One is equipped with an Emergency switch. The Emergency switch is below the control panel. Fig.5: Emergency switch Mantis ULV Sprühgeräte GmbH Page 13 of 29...
  • Page 14: Testing Of Emergency Switch

    If your BioMant One model includes a LPG-Burner, it will also be equipped with an LPG shut-off valve, This valve must be turned on completely to open the LPG supply. Fig.7: Shut-off valve for LPG hot water burner Mantis ULV Sprühgeräte GmbH Page 14 of 29...
  • Page 15: Assembly Instructions

    Place the BioMant One in a well-ventilated room to evacuate exhaust fumes and prevent the generation of potentially explosive gases. Please find an overview on the fuel system attached to these Operating Instructions (see 10.4). Mantis ULV Sprühgeräte GmbH Page 15 of 29...
  • Page 16: Measures Prior To Commissioning

    If this is not the case, refill oil. > Coverings and safety devices must be installed and work properly. > For machines with battery pack: Make sure that all batteries have been fully charged. Mantis ULV Sprühgeräte GmbH Page 16 of 29...
  • Page 17: Commissioning, Test Run And Working Operation

    > Keep the spray gun pressed > Finally, the display will show green, signalling the correct water temperature has been reached and the machine is ready for use. Mantis ULV Sprühgeräte GmbH Page 17 of 29...
  • Page 18: Test Run / Working Operation

    Avoid repeated pressing and releasing of the spray gun within too short periods of time because this causes a loss in water temperat high current consumption and pollution of the machine. Mantis ULV Sprühgeräte GmbH Page 18 of 29...
  • Page 19: Working With The Biomant One Weed Control Machine

    Replace the filter cartridges by new filter cartridges be removing them from the plexiglass housing and inserting the new filter cartridge. > Screw on the plexiglass housing again (counterclockwise). Fig.7: Location of Waterfilter Mantis ULV Sprühgeräte GmbH Page 19 of 29...
  • Page 20: Charging Of Batteries

    Replace the empty canister by a full canister of BioMant Kalk-Stop. > Reconnect the hose. > Adjust the dosing unit for anti-lime scale according to the hardness of your water, as described in 10.3 below. Mantis ULV Sprühgeräte GmbH Page 20 of 29...
  • Page 21 Anti-lime scale agent Always use BioMant Kalk-Stop as anti-lime scale agent. Prior to use read the material data safety sheet of BioMant Kalk-Stop and follow all instructions of the material data safety sheet. Mantis ULV Sprühgeräte GmbH Page 21 of 29...
  • Page 22: Adjustment Of The Dosage For Anti-Lime Scale Agent

    ˃ 4.5 ˃ 10 ˃ 5 ˃ 11 ˃ 5.5 ˃ 15 ˃ 7.5 ˃ 20 ˃ 10 ˃ 23 ˃ 11.5 ˃ 27 ˃ 13.5 ˃ 28 ˃ 14 1000 *Standard settings Mantis ULV Sprühgeräte GmbH Page 22 of 29...
  • Page 23: Maintenance Works And Troubleshooting

    Only the manufacturer or your BioMant dealer is allowed to do this. Before starting any works on the burner, let it cool down first. The boiler is filled with hot water that can cause burnings. Mantis ULV Sprühgeräte GmbH Page 23 of 29...
  • Page 24 Eliminate the reason for the malfunction and restart the machine. For malfunctions that are not listed in these Operating Instructions, please contact your dealer or the manufacturer. Mantis ULV Sprühgeräte GmbH Page 24 of 29...
  • Page 25: Disassembly, Transport, Storage And Disposal

    The batteries must be fully charged minimum once a month, also when the machine is not use, e.g. out fo season.. Complete and repetitive discharge will cause serious damages to the batteries! Mantis ULV Sprühgeräte GmbH Page 25 of 29...
  • Page 26: Disposal

    > Dispose of plastic waste as residual waste or supply it to a special recycling company. > Dispose of used chemicals by means of an especially certified recycling company. Mantis ULV Sprühgeräte GmbH Page 26 of 29...
  • Page 27: Annexes

    Furthermore, the machine is in compliance with the following standards: EN-ISO 12100:2010, EN-ISO 13850, EN-ISO 13849-1, EN-ISO 13857, EN-ISO 14120, EN-ISO 14118 Place, date: Name, Position: Geesthacht, 17 March 2020 H. Weissmann, General Manager Signature of authorized person Mantis ULV Sprühgeräte GmbH Page 27 of 29...
  • Page 28: Schematic Diagram

    10.2 Schematic diagram Mantis ULV Sprühgeräte GmbH Page 28 of 29...
  • Page 29: Spare Parts List

    BioMant ONE/TWO (WS-I/II) Ersatzteilen / Spare Parts list Artikel Nr. Bezeichnung Deutsch Bezeichnung Englisch Mantis 112210 Elektrische Pumpe, M100 3HP 3P++, ONE / WS MOTOR M100 3HP 3P + Pump E3B2515+BYPASS 112211 Diesel Boiler 20L mit Steuerung, ONE / WS DIESEL BOILER 20 LT + ELECTRICAL BOX 220V 112212 Elektrode 8mm LPG Brenner, ONE / WS...
  • Page 30 BioMant ONE/TWO (WS-I/II) Ersatzteilen / Spare Parts list Artikel Nr. Bezeichnung Deutsch Bezeichnung Englisch Mantis 112289 DRUKREGELAUTOMATEN für Wasserkreislauf WS-I & II Pressure regulator for water circuit WS-I & II 112290 Durchflussschalter, Diesel-Brenner WS-I & II Flow switch, diesel burner WS-I & II 112291 Schalter, Microschalter, Aquajet-Pumpe Switches, microswitches, Aquajet pumps...

Table of Contents