Model PS-2001L Power Supply Model SPS-2001 Power Supply 9350-7699-000 Rev C ™ ™ 06/2006...
Page 2
OTICE The product information and design disclosed herein were originated by and are the property of Telex Communications, Inc. Telex reserves all patent, proprietary design, manufacturing, reproduction, use and sales rights thereto, and to any article disclosed therein, except to the extent rights are expressly granted to others.
Page 5
Description The PS-2001L and SPS-2001 are versatile power supplies that can be used in a variety of Audiocom applications. They both directly accept any AC input power from 100 to 240 VAC, 50/60 Hz and can be configured to power two separate intercom channels or one large intercom channel with twice the intercom station capacity.
Page 6
The default setting for this switch is in the Audiocom position. ® 100-240 VAC 60/50 HZ TELEX COMMUNICATIONS, INC. MADE IN USA SPS-2001 Front and Rear Panel Features FIGURE 2. Speaker, Inputs, and Volume Control: Two audio inputs are provided. The inputs are combined internally and set as a monaural signal to the internal speaker amplifier.
Page 7
Description Intercom Channel Connectors: When the Combine/Isolate switch is set to the Isolate position, each channel connector is powered separately and has completely separate intercom audio. When the Combine/Isolate switch is set to the combine position, each channel is still powered separately, but the audio signals are combined so that all users on both channels can intercommunicate.
Channel Capacity: When connecting intercom stations to the PS-2001L or SPS-2001, determine the total current for all stations on each channel. The total per channel should no exceed 2A. If you exceed this limit, an overload indication will be provided and the output of the power supply will be turned OFF.
Page 10
Installation For rack mounting, use an optional Audiocom Rackmount Kit. Several kits are available to meet the requirements of your particular system. Follow the assembly instructions supplied with the rack mount kit. Shield Cable Type: 22AWG Stranded, 2-Pair Twisted-wire, with Shield Connector Type: 3-Pin XLR Audio (Neutrik or Switchcraft) Pin 1: Common Pin 2:...
Page 11
Desktop or Rackmount Installation BP-1000 BP-1000 HEADSET BP-2000 BP-2000 BP-1000 HEADSET Typical connections using a single PS-2001L Power Supply to power two channels. FIGURE 4. PS-2001L Power Supply Combine / Isolate Switch set to Isolate CH 1 CH 2 100-240 VAC 60/50 HZ TELEX COMMUNICATIONS, INC.
Page 12
HEADSET LINES LINES HEADSET Typical connections using on SPS-2001 Power Supply for two intercom channels. The 1-channel cable 2-channel cable “Y” cable US2000A PUSH Master Station...
Page 13
Desktop or Rackmount Installation SPK1000 Powered Speaker TELEX COMMUNICATIONS, INC. MADE IN USA 12-15 VDC Speaker inter- connect cables. Program input cable. From 2 audio sources BP-1000 BP-1000 HEADSET BP-2000 BP-2000 BP-1000 HEADSET Adding an SPK-1000 to the example in Figure X. The two program sources are monitored FIGURE 6.
Page 14
(Optional) To ½ of stations To ½ of stations on channel 1 on channel 2 Using two PS-2001L Power Supplies to provide a greater capacity on each channel. SPS-2001 Channel 1 Power Channel 2 Power Combine / Isolate Switch set to Combine...
DC wallpack supplies are connected. To correct the problem, plug in the DC wallpacks. Plug in the AC power cords for any connected PS-2001L or SPS-2001 Power Supplies. The channel status indicators should be green.