T7
Start-up, Service and Operating Manual
Rev. 1.00.03a | 23.06.23 11:09
Technische Änderungen vorbehalten

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T7 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Meusburger T7

  • Page 1 Meusburger Georg GmbH & Co KG Kesselstraße 42 | 6960 Wolfurt | Austria T +43 5574 6706 office@meusburger.com www.meusburger.com Start-up, Service and Operating Manual Rev. 1.00.03a | 23.06.23 11:09 Technische Änderungen vorbehalten...
  • Page 3: Table Of Contents

    CONTENT Introduction General information Safety Instructions Warranty conditions Transport and storage Disposal Symbol meanings Operation Touch operation gestures Image layout Process data and parameter display 2.3.1 Standard 2.3.1.1 Selection of the number of zones per screen page 2.3.1.2 Select zone area 2.3.1.3 Background colour 2.3.1.4 Output value display (as bars) 2.3.2...
  • Page 4 Installation of a third language Technical data Installation plan Annex Version history documentation Accessories...
  • Page 5: Introduction

    MPI 05  PURPOSE OF THIS DOCUMENTATION This user manual contains information that you need for the start-up, operation and maintenance of the T7 operating unit. TARGET GROUP This documentation is intended for qualified personnel in the following fields: »...
  • Page 6: Safety Instructions

    If you wish to use services within the framework of this guarantee, please contact the manufacturer/suppli- TRANSPORT AND STORAGE TRANSPORT The components of the T7 system are delivered in a robust carton, in shockproof packaging. This ensures sufficient protection under normal circumstances. www.meusburger.com...
  • Page 7: Disposal

    Check the package and the product delivered for visible transport damage. If damage is identified, please contact the transport company. Damage to the system Damaged parts can lead to damage to the system. Do not put any damaged components of the T7 system into operation! STORAGE If the unpacked device is not immediately put into operation, it must be stored so it is protected from dirt and moisture.
  • Page 8 Start-up, Service and Operating Manual T7 REFERENCES IN THE OPERATING MANUAL Cross reference: In the PDF version of the document the link brings you to the cross ä reference. Equations Calculation specifications and examples <View> Menu points e.g. view are represented through a < > bracket.
  • Page 9: Operation

    During operation, access to all setting values (configuration parameters, system settings of the controller, and T7, ...) is controlled via one user 2.9.6 User Management . In this manual it is assumed that the user Admin has full access to all data. If you do not have the appropriate rights, please contact the user with full access rights to assign the setting or to give you rights to edit the setting value.
  • Page 10: Process Data And Parameter Display

    The ‘Standard’ display mode is ac- cessed via the ‘Standard’ button, which can be found under the menu item ‘Views’. The T7 has saved the number of zones per page selected in this display mode during the last use and switches it on. 2.3.1.1 SELECTION OF THE NUMBER OF ZONES PER SCREEN PAGE The number of zones displayed on one screen page can be selected.
  • Page 11 Chapter 2 - Operation Zone display Number of Continuously visible process Additionally selectable process zones per values values screen page » Zone number / zone name » Set point value » Actual value » Output value (numeric) » Heating current »...
  • Page 12: Select Zone Area

    Start-up, Service and Operating Manual T7 2.3.1.2 SELECT ZONE AREA If the respective controller has more zones than the number of zones shown on the screen page, a vertical swiping gesture can be used to switch to the next or previous zones page by page.
  • Page 13: Select Zone Area / Parameter

    Chapter 6 - Operation In this display mode, T7 reverts to the position in the table when last used. 2.3.2.1 SELECT ZONE AREA / PARAMETER Swiping gestures are used to access the screen area of the parameters for specific zones.
  • Page 14: Background Colours

    Start-up, Service and Operating Manual T7 2.3.3.1 BACKGROUND COLOURS Just like for the zone view, the colour of the zone field indicates the state of the control zone. The zone is passive. No output value is displayed at the control outputs.
  • Page 15 Chapter 6 - Operation The input dialogue is displayed. The selected zone is marked and the parameter from the last entry is selected in the parameter list. Swipe vertically to navigate the parameter and zone lists. All zones can be selected or deselected with the function keys in the menu bar on the right side of the screen.
  • Page 16: Copy Zone Parameters

    Start-up, Service and Operating Manual T7 A selection is made from a predefined selection list. KEYS FOR THE NUMERIC INPUT AREA Additional function keys provide support when entering numerical parameters. The setting value is directly increased or decreased by one.
  • Page 17: Assign Zone Names

    Chapter 6 - Operation The zone parameter copy screen appears. It is divid- ed into 4 areas. » The one zone that is used as a copy template is highlighted in the zone list on the left. » The zone(s) that is/are to be copied to are select- ed in the zone list on the right.
  • Page 18: The Controller Unit

    THE CONTROLLER UNIT You can connect more than one controller, but you can only view/work on one at a time through the T7, not several at once. Project planning with the controllers must have been successfully carried out and the controllers recognised by the T7 (3 Start-up).
  • Page 19: Alarm Status

    Chapter 6 - Operation 2.9.6 User Management. ALARM STATUS If there is an alarm status in at least one zone, this is indicated by the red alarm button. There is no alarm in any zone. There is an alarm in at least one zone. After tapping the button, the screen page with the alarms is opened.
  • Page 20: Switch Controller On/Off

    This function can be used to switch the control outputs of all control zones of the specific controller on or off. INFO CENTRE System settings for the T7 can be made in the Info Centre and system functions for the respective controller can be accessed. The Info Centre can be reached by swiping down...
  • Page 21: Position Menu Bar

    2.9.5 COMMUNICATION PARAMETERS The settings for the Ethernet and the CAN data interfaces for the T7 are made here. Please see the detailed notes in section 3.2 Setup . Select a parameter in the right field and adjust it in the input area.
  • Page 22 Start-up, Service and Operating Manual T7 User level Factory set pass- Description word Standard This user is automatically used if no other user level is activated. This user level should have the least access rights to settings and screen pages.
  • Page 23: Date / Time

    Only the two approved menu items can be selected. 2.9.7 DATE / TIME The date and time can be changed here. The changes are stored in the T7 in a power-failure-proof manner. 2.9.8 HARDWARE SETUP This is where the system is configured and where the T7 stores which controllers are connected to it via which data interfaces.
  • Page 24: Start-Up

    MPI 05  It is possible to connect controllers to both the CAN and the Ethernet interfaces of the T7 and use them si- multaneously. For example, controllers of the systemp II series via CAN and simultaneously controllers from the flexotemp series via Ethernet.
  • Page 25: Can

    X10.7 X10.2 The flexotemp PCU and PCU PNIO controllers can optionally also be networked with a T7 via the internal CAN system bus using flexotemp BE or flexotemp CANBE (3.2.2.1 Addressing). For controllers of the systemp II and the systemp net series, the pin assignment of the CAN is according to the specification of the controller (PSG CAN or CAN open).
  • Page 26: Ethernet

    It must be ensured that all controllers connected to the T7 have a unique IP address, that they are in the same address range as the T7 and only differ in the last octet. The T7 is delivered from the factory with the IP 192.168.0.100, PSG controllers have the IP 192.168.0.220.
  • Page 27 The progress of the hardware setup is displayed with a bar. When the process is complete, the controllers found are entered in the list. The list is stored in T7 in a power-failure-proof manner when the input is termi- nated.
  • Page 28: Can

    Each controller connected to the T7 via CAN must have its own unique CANopen address (Node-ID). For all controllers, the identical CANopen base address must be set for operation on a T7. This is preset at the factory as the CANopen base address on all controllers.
  • Page 29 When the process is complete, the controllers found are entered in the list. The list is stored in T7 in a power failure safe manner when the input is closed. After completing the hardware setup, the user is directed to the info centre.
  • Page 30: Device Update

    » Insert the USB flash drive in the T7 USB port. » If the T7 is switched off, switch the T7 on. If the T7 is switched on, disconnect the T7 from the power supply briefly. » When booting, the T7 recognises the USB flash drive and offers the following functions: »...
  • Page 31 For the parametrisation of the connected controllers Address Configurable Connector RJ45 socket Front side for memory stick - for T7 firmware update (in planning stages: firmware update controller, data import/export) Display 7“ TFT, capacitive touch screen GENERAL TECHNICAL DATA Maximum number of connecta-...
  • Page 32 Start-up, Service and Operating Manual T7 6,00 mm 6,00 mm 198,00 mm www.meusburger.com...
  • Page 33 Chapter 4 - Annex ANNEX VERSION HISTORY DOCUMENTATION Date Version Change 23.06.2023 1.00.03a Minor, formal changes 15.12.2020 1.00.03 PCU NEXT integrated Change sysTemp to systemp 10.11.2020 1.00.02a Correction figures chapter 2.3.1.1 27.07.2020 1.00.02 Corrections 22.03.2020 1.00.01 Corrections Device update chapter added 12.03.2020 1.00.00 First edition...