INSTALLATION
Standard ducting installation
It is recommended that the unit be positioned at a
minimum of 600mm for an electric cooktop and 650mm
for a gas cooktop, and no further from the cooktop than
800mm. Then unit becomes less effective as the distance
from the cooking surface to the rangehood increase.
underside of
rangehood
650
top of cooking
surface
Fixing point dimensions – ERR627SA ERR627DSD
Ø
rear cover can be reversed
to suit gap at rear
Fixing point dimensions – ERR927SA ERR927DSD
Ø
WARNING!
Failure to install the screws or fixing device in
accordance with these instructions may result in
electrical hazards.
if the cooktop
manufacturer
a greater
600
clearance
then that
must be used
rear cover can be reversed
to suit gap at rear
Parts supplied with hood
1 x Ø 150mm air outlet
1 x Ø 150mm to Ø 120mm converter
2 x rear covers
2 x lateral covers
6 x self tapping screws 3 x 12mm
2 x self tapping screws 3.5 x 10mm
4 x Ø 6 washers
4 x M6 x 40 screws
2 x air intake grilles
Parts to be purchased
Aluminium tape or cable ties to secure flue pipe
Ducting accessories
Drilling holes
Drill the holes on top wooden support
• drill Ø 7mm hole
• drill Ø 16mm hole
• cut Ø 196mm hole
Ø 7 for hood
fastening screws
86
196 for flue
Ø
clearance
33
453/753
door/hood fascia
front of
cabinet
Fixing the air outlet
ST 3.5 x 10
Fixing the lateral cover
Use screws to fix the lateral cover to the rangehood.
Ø 16 for cable
clearance
ST 3 x 12