ET 200 N 1140807 (110V 50Hz) HOIST Operating,maintenance,spare parts manual Contact Us Unit R1D Rockingham Gate Poplar Way West Cabot Park Tel: 0117 9381 600 Bristol Fax: 0117 9381 602 BS11 0YW email: sales@safetyliftingear.com...
Dear customer, withstand the stresses generated during operation (Þ g. 2). Congratulations on purchasing a reliable and innovative The 400 N force is perpendicular to the 5000 N force. Since the product created through years of experience. hoist is able to rotate on the supporting hinges, these forces must be veriÞ...
5. TESTING correctly keeping the rope tensioned at all times. - 15) Ensure that the travel and work area is free of ob- - Warning!! Testing must be carried out by qualifi ed stacles throughout the height and take necessary precautions personnel only.
1) Fully unwind the rope. 2) Withdraw the rope from the inside of the drum through the hole and the slot. 3) Feed the new rope into the hole and out of the slot on the side of the drum (Þ g. 4.1). 4) Tighten the clamp at the end, leaving a free end approximately 1 cm long, and pull the rope to bring the clamp up against the internal wall of the drum.
which can adversely affect its functionality and mechanical - CAUTION! Before working on the brake, ensure that strength. the load is removed, the electric power plug is disconnected 10. SCRAPPING THE HOIST and the motor is cool. To scrap the machine at the end of its service life, carry out the following steps: a) Drain out the oil by removing the oil plug.
Page 6
SCHEMA ELECTRICO - WIRING DIAGRAM - Fig.6 CONDUTTORE DI PRO- PROTECTION WIRE TEZIONE CONDUTTORE NEUTRO NEUTRAL WIRE CONDUTTORE DI LINEA PHASE WIRE PULSANTE ARRESTO STOP BUTTON PULSANTE SALITA UPSTROKE BUTTON PULSANTE DISCESA DOWNSTROKE BUTTON FINECORSA SALITA UPSTROKE LIMIT SWITCH CONNETTORE MOTORE MOTOR CONNECTOR CONDENSATORE CAPACITOR CONDENSATORE...
Page 7
PUNTELLO PER INTERNI Fig. 7 HOIST FRAME FOR INTERMEDIARY FLOORS POSIZIONE APPOGGIO SUPERIORE POSITIONING TOP FOOT TRAVE BEAM ELEVATORE HOIST TRAVE BEAM LIVELLA ZONA LAVORO OPERATORE SPIRIT LEVEL OPERATOR WORK ZONE PARAPETTO PARAPET cod. 1199102 Fig. 8 KIT PER PUNTELLO DA ESTERNI CONTENITORE ZAVORRA HOIST FRAME FOR ROOFS COUNTER WEIGHT...
Page 8
PUNTELLO A FINESTRA Fig. 11 HOIST FRAME FOR WINDOWS POSIZIONE DI LAVORO WORKING POSITION ELEVATORE HOIST FINESTRA WINDOW ZONA LAVORO OPERATORE OPERATOR WORK ZONE cod. 1199105 STRUTTURA DI SUPPORTO A CAVALLETTO IMER (PORTATA MAX 200 kg) IMER GANTRY HOIST ( MAX CAPACITY 200 kg) Fig.
Page 9
Fig. 14 PUNTI DI VISIBILE APPIATTIMENTO VISIBLE FLATTENED POINTS CORROSIONE INTERNA O ESTERNA INTERNAL OR EXTERNAL CORROSION ROTTURA DI UN TREFOLO BREAKING OF ONE STRAND ROTTURA DI SINGOLI FILI BREAKING OF SINGLE WIRES FORMAZIOME DI ANSE LOOPS RICAMBI: Per tutti gli ordini dei pezzi di ricambio vogliate indicare: 1 - Tipo di macchina. 2 - Numero di codice e di riferimento collocato in corrispondenza di ogni deÞ...