Portable Humidifier PUM100B 
 
 
 
 
 
 
 
 
 
 
 
Background and Purpose 
Humidity  is  often  used  to  enhance  and  accelerate  latent  print  development.  The  addition  of  humidity  in  the 
processing of Ninhydrin treated documents is common place and it's also a key component in Cyanoacrylate fuming 
techniques. The PUM100B provides a controlled method of introducing moisture to both of these processes. The 
Humidifier can be used in conjunction with Cyano Fuming Chambers such as the FR100, FR200, FR600 and also for 
humidifying documents processed with Ninhydrin by using the included hose nozzle attachment or connecting to 
the 214CA Development Chamber.  
Safety Precautions 
NOTICE: Elevated temperature mist may be generated by this unit when the Warm Mist mode is selected. Do not 
touch the outlet nozzle plate during operation. Do not touch the outlet end of the hose. 
 To avoid hazard of fire or shock, plug unit directly into an appropriate AC outlet.  
 Do not use an extension cord.   
 Do not operate the unit without the water tank.  
 Do not place near heating devices or in direct sunlight.  
 Do not store or use flammable materials (acetone, alcohol, etc.) near the unit.   
 Do not use any substances other than those recommended to clean the unit, as it will interfere with the proper 
operation of the unit.  
 Do not use anything other than distilled water in the water tank. 
 Do not use sharp or metal objects to remove mineral deposits.   
 Do not let water enter the air inlet or any other openings when cleaning.  
 Do not immerse the unit in any liquid.  
 Turn OFF before moving the unit.   
 Prior to storage always unplug the unit then empty the water tank and the base. 
100 HUNTER PLACE, YOUNGSVILLE, NC 27596 USA 
Voice: (919) 554‐2244, (800) 356‐7311 • Fax: (919) 554‐2266, (800) 899‐8181 
• Web: www.sirchie.com • Email: sirchieinfo@sirchie.com 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PUM100B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SIRCHIE PUM100B

  • Page 1 Technical Information TI02-101ENG-R8.2 Portable Humidifier PUM100B                        Background and Purpose  Humidity  is  often  used  to  enhance  and  accelerate  latent  print  development.  The  addition  of  humidity  in  the  processing of Ninhydrin treated documents is common place and it's also a key component in Cyanoacrylate fuming  techniques. The PUM100B provides a controlled method of introducing moisture to both of these processes. The  Humidifier can be used in conjunction with Cyano Fuming Chambers such as the FR100, FR200, FR600 and also for  humidifying documents processed with Ninhydrin by using the included hose nozzle attachment or connecting to  the 214CA Development Chamber.   Safety Precautions  NOTICE: Elevated temperature mist may be generated by this unit when the Warm Mist mode is selected. Do not ...
  • Page 2 Technical Information TI02-101ENG-R8.2 Product Information  Electrical Data:   Input Voltage   120V AC/60Hz  Power use   25 watts (cool mist – default operation)  85 watts (Warm Mist setting)  AC power cord  Double‐insulated polarized 2‐blade  Physical Data:   Height   13.5 in.  (34.3 cm)    Width  12.4 in.  (31.5 cm)  Depth  10.3 in.  (26.3 cm)  Weight without water  6.45 lbs. (2.93 Kg)  Water Tank Capacity   2 gal.  (7.57 liters)    Parts Description      Mist Nozzle    100 HUNTER PLACE, YOUNGSVILLE, NC 27596 USA  Voice: (919) 554‐2244, (800) 356‐7311 • Fax: (919) 554‐2266, (800) 899‐8181  • Web: www.sirchie.com • Email: sirchieinfo@sirchie.com ...
  • Page 3 Technical Information TI02-101ENG-R8.2 Controls / Operation    Power button: Pushing this button toggles power ON and OFF. Make certain the tank contains water before  powering the unit on.  Night Light button: Turns the unit’s Night Light ON or OFF (toggle).  Mist Control: Press once for LOW mist volume, press twice for MEDIUM mist volume or press three times  for HIGH mist volume. The corresponding L, M or H LED under the button will be lit, indicating the selection.  Refill Tank ‐ When all three LEDs under the Mist Control button are blinking, the water tank needs refilling.   Warm Mist Control button ‐ Press to select warm mist. When warm mist is selected, the LED under the  WARM button will light. Water temperature is maintained at 80 °F (27°C) for warm. Allow 15 minutes for  water to warm. To turn off the Warm Mist function, press the button again.  Cool Mist ‐ This is the default operation of the unit. Mist will be generated by the unit’s ultrasonic  mechanism. The mist temperature will be that of the water in the tank (i.e., room temperature).  Timer ‐ By default, the Timer function is “off”, meaning the unit will run until you turn it off or it runs out of  water. For use with Sirchie chambers, the Timer functionality is not needed. See “Recommended Mist  Settings for Sirchie Chambers”, on the following page, for recommended run times.      100 HUNTER PLACE, YOUNGSVILLE, NC 27596 USA  Voice: (919) 554‐2244, (800) 356‐7311 • Fax: (919) 554‐2266, (800) 899‐8181  • Web: www.sirchie.com • Email: sirchieinfo@sirchie.com ...
  • Page 4 Technical Information TI02-101ENG-R8.2 Filling The Water Tank    1. Before filling the water tank, set the  POWER button to “OFF” and unplug the  unit from the AC outlet.   2. Remove the lid from the water tank.  Fill tank with distilled water only  (Recommended Sirchie PUM105.)  Replace the tank lid.    Use With Cyanoacrylate Fuming Chambers  1. Place the base of the PUM100B on a firm, flat, level and water resistant surface.   2. Fill the tank (as explained above).   3. Plug the power cord firmly and completely into the wall outlet (do not use an extension cord).   4. Connect one end of the vapor hose to the PUM100B’s nozzle‐hose adapter tube (on top of the unit).   5. Push the power button to turn the unit ON.  6. Press the Mist Control button to select the volume of mist desired (Low, Medium or High).   7. If you want Warm Mist, press the Warm button. Note that it will take about 15 minutes to warm up the water.  Otherwise the unit will produce a cool mist via its ultrasonic mechanism.  8. To select a Timer duration, press the Timer button. Each time the button is pressed, the next Timer interval is  selected. The “2 hour” setting should be sufficient for most operations.  The unit’s heater (if Warm Mist is selected) shuts off automatically when water runs out. Also the unit will cease  producing mist if the water runs out.    Recommended Runtimes and Mist Settings for Sirchie Chambers    Recommended  Recommended   ...
  • Page 5 Technical Information TI02-101ENG-R8.2 Alternative Uses   Besides  its  value  in  increasing  the  relative  humidity  in  closed  fuming  chambers,  the  PUM100B  may  be  used  to  introduce moisture onto other objects such as Ninhydrin treated paper documents.   The PUM100B includes a dispersion head that attaches to the free end of the mist vapor hose for this application.                       Cleaning and Maintenance  CAUTION! Use only Sirchie PUM105 distilled water! Tap water  contains  minerals  and  other  particles  that  may  contaminate ...
  • Page 6 Technical Information TI02-101ENG-R8.2 DESCALING    Depending  on  usage,  cleaning  to  remove  scale  may  be  required  weekly  or  every  other  week  to  optimize  unit  performance. Use only distilled water in the unit (SIRCHIE PUM105 recommended). This will reduce the precipitation  of minerals or ‘white dust’. Do not clean the unit or water tank with detergents or cleaning chemicals of any kind.   If scale becomes difficult to remove with brush:  1. Fill the tank with: mixture of 1 tsp. white vinegar and 1 tsp. water.   2. Let solution stand for 5 minutes.  3. With the vinegar in the tank, clean all interior surfaces with a soft cloth or brush to help remove scale.   4. Also check mist nozzle and mist tube in water tank. Clean as needed.  5. Rinse the tank thoroughly with water to remove scale and vinegar solution.    ULTRASONIC DISK MAINTENANCE      1. Unplug unit.   2. Remove the mist tube by rotating it counter clockwise.  Empty the tank by pouring all the water on the left side  (see arrow inside tank). ...
  • Page 7 Technical Information TI02-101ENG-R8.2 Troubleshooting Guidelines                                      100 HUNTER PLACE, YOUNGSVILLE, NC 27596 USA  Voice: (919) 554‐2244, (800) 356‐7311 • Fax: (919) 554‐2266, (800) 899‐8181  • Web: www.sirchie.com • Email: sirchieinfo@sirchie.com ...

Table of Contents