Attention to security To ensure your safety, reduce accidents happens, before installation please must read the installation manual carefully, and operation is strictly complying with the installation manual. If you have some questions, please ask the specialists and the dealers. The installation worker must inspect the door before installation, only allows installation the opener at balance state, Otherwise it could have serious consequences.
Technical parameter Rated voltage: AC230V±10% 50Hz Open and close force 600N /800N/ 1000N /1200N Motor: 24VDC Transmission frequency: 433.92MHz Decoding: Rolling Code Transmitter: 27A 12V /CR2032 3VBattery Standby power: <6W Work temperature: -20℃~+50℃ 3 minutes Courtesy Light: 4 minutes Rated Operation Time:...
Page 4
Install the Header Bracket and the door bracket Attach the Rail to the Header Bracket...
Page 5
Door arm connection 2. Attach the straight door arm to the outer Close the door. Disconnect the trolley trolley using the Shouldered shaft, short (H6). by pulling the emergency release handle. Attach with the Cotter Pin (H5).
Page 6
Bring arm sections together. Find two pairs 3. Attach the curved door arm to the door of holes that line up and join sections. Select bracket using the Shouldered shaft, short holes as far apart as possible to increase door (H6).
Page 7
5. Pull the emergency release handle toward the garage door opener until the trolley release arm is horizontal. The trolley will re-engage automatically when the garage door opener is activated.
Control Box---Overview Enter Function Setup Menu Confirm chosen function or value In Standby :Enter Transmitter Setup Menu In Setup Menus: Scroll Function In Setup Menus: Scroll Function Basic function settings Adjusting the Open and Close Limits Press ‘ST ’ button and hold on until the LED displays ‘1’.
Page 9
Press and hold the ‘CL‘ button until the door reaches the desired close position. For fine adjustments toggle OP &CL buttons. Press the ‘ST’ button to confirm the close position. The door is now set for normal operation. 2 Programming Hand Transmitters NOTE: Hand transmitters that are supplied with the door opener is pre-programmed.
Advanced function settings 1 Time to close Press ‘OP ’ button and hold on until the LED displays ‘ ’. Press the OP &CL buttons to select closing time. Level Value 1minute 2 Level Value Press the ‘ST ’ button to confirm it. 2 Safety Photo Beam Press ‘CL’...
3 Close force adjustment DIP1 The jumper connects ‘ DIP1’ and ‘2’ meant MAX close force. DIP1 DIP1 The jumper connects ‘2’ and ‘ 1’ meant 50% close force. External Interface PBSW GND PB ALM+ ALM- SD+ Backup battery Battery...
Need help?
Do you have a question about the CN Series and is the answer not in the manual?
Questions and answers