Control unit for rgb led fixtures in costant current 350-700 ma (jumper setting) power supply in 12-36vdc. rx radio 433.920 mhz, 3 push n.o. inputs, extender connector available (16 pages)
Summary of Contents for L&L TLR04M-350-500
Page 1
INSTALLATION INSTRUCTIONS TLR04M-350-500 TLR04M-350-500 Power supply units and control gear Alimentatori ed elettronica di controllo Made in Italy IP20 12 ÷ 36 Vdc - 433.92 MHz TLR04M-350-500 CONTROL UNIT FOR RGB LED FIXTURES IN COSTANT CURRENT 350-500 mA (JUMPER SETTING).
INSTALLATION INSTRUCTIONS TLR04M-350-500 TLR04M-350-500 CONNECTION DIAGRAM OUT3 BLUE LED OUT2 Loads with constant GREEN LED current (choose a load that’s compatible with the power supply in terms OUT1 of power). RED LED 9 10 11 12 13 14 12 to 36 Vdc...
INSTALLATION INSTRUCTIONS TLR04M-350-500 TLR04M-350-500 SET THE OUTPUT CURRENT With the jumper is possible to set the current provided to the Leds. The selection is different for each out: OUT3 OUT2 OUT1 JUMPER INSERTED= JUMPER NOT INSERTED= 500mA 350mA L&L Luce&Light srl / Via Trescalini, 5 / 36031 Dueville, Vicenza / Italy / T +39 0444 36 05 71 / F +39 0444 59 43 04...
Page 4
INSTALLATION INSTRUCTIONS TLR04M-350-500 TLR04M-350-500 PUSH N.O. USAGE FIXTURES FIXTURES INPUT P1: short pressure INPUT P1: Dimmer up Dimmer up / Dimmer down long pressure Color change refered to a memorized palette (white, light INPUT P2: no actions yellow, light green, dark green, light blue, blue, violet, light...
Page 5
INSTALLATION INSTRUCTIONS TLR04M-350-500 TLR04M-350-500 RADIO PROGRAMMING PROCEDURE: STEP 1 STEP 2 Short press on the “SET” key let you A prolonged press on the “SET” key scroll through the menu until “P1” pro- (approx. 3 seconds) takes you into pro- gramming appears on the display.
Page 6
INSTALLATION INSTRUCTIONS TLR04M-350-500 TLR04M-350-500 LOAD STATE WHEN THE CONTROL UNIT IS SWITCHED ON Default: Light Off This process is used to set the state of Leds when the control unit is switched on (for example when the power supply is provided by a general switch or timer).
INSTALLATION INSTRUCTIONS TLR04M-350-500 TLR04M-350-500 FACTORY SETTING, RESET This procedure let you take the control unit back to factory settings. PROCEDURE: STEP 1 Short presses on the “SET” key let you scroll through the menu until “FS” pro- gramming appears on the display.
Page 8
INSTALLATION INSTRUCTIONS TLR04M-350-500 TLR04M-350-500 L&L Luce&Light srl / Via Trescalini, 5 / 36031 Dueville, Vicenza / Italy / T +39 0444 36 05 71 / F +39 0444 59 43 04 E lucelight@lucelight.it / www.lucelight.it...
ISTRUZIONI DI INSTALLAZIONE TLR04M 350-500 TLR04M-350-500 Power supply units and control gear Alimentatori ed elettronica di controllo Made in Italy IP20 12 ÷ 36 Vdc - 433.92 MHz TLR04M-350-500 CENTRALE DI COMANDO PER LED RGB IN CORRENTE COSTANTE 350-500 mA (JUMPER SU OGNI USCITA).
ISTRUZIONI DI INSTALLAZIONE TLR04M-350-500 TLR04M-350-500 SCHEMA DI COLLEGAMENTO OUT3 LED BLU OUT2 Carichi corrente LED VERDE costante (scegliere un il carico compatibile con l’ali- mentatore in termini di OUT1 tensione e potenza). LED ROSSO 9 10 11 12 13 14...
Page 11
ISTRUZIONI DI INSTALLAZIONE TLR04M-350-500 TLR04M-350-500 SELEZIONE DELLA CORRENTE IN USCITA Con i jumper in scheda è possibile selezionare la corrente con la quale la centrale alimenta il carico. La selezione può essere fatta per ogni uscita separatamente: OUT3 OUT2 OUT1...
Page 12
ISTRUZIONI DI INSTALLAZIONE TLR04M-350-500 TLR04M-350-500 UTILIZZO VIA INPUT PULSANTE NA CARICO CARICO SPENTO ACCESO INGRESSO P1: On del carico Off del carico pressione breve INGRESSO P1: Dimmer up intensità Dimmer up intensità / Dimmer down intensità pressione lunga Cambio del colore (bianco, giallo chiaro, verde chiaro, ver-...
Page 13
ISTRUZIONI DI INSTALLAZIONE TLR04M-350-500 TLR04M-350-500 PROGRAMMAZIONE RADIO PROCEDURA: PASSO 1 PASSO 2 Con pressioni brevi del tasto “SET” Fare una pressione prolungata del ta- scorrere il menù fino a visualizzare sul sto “SET” (circa 3s) per entrare nella display la programmazione “P1”.
Page 14
ISTRUZIONI DI INSTALLAZIONE TLR04M-350-500 TLR04M-350-500 STATO DELLA LUCE ALL’ALIMENTAZIONE DELLA CENTRALE Default: Luce spenta Con questa procedura si imposta lo stato della luce quando la centralina viene alimentata (utile ad esempio se la centrale è alimentata da un interruttore generale o da un orologio a monte).
Page 15
ISTRUZIONI DI INSTALLAZIONE TLR04M-350-500 TLR04M-350-500 IMPOSTAZIONI DI FABBRICA, RESET DELLA CENTRALE Con questa procedura è possibile portare la centrale alle impostazioni di fabbrica. PROCEDURA: PASSO 1 Con pressioni brevi del tasto “SET” scorrere il menù fino a visualizzare sul display la programmazione “FS”.
Page 16
ISTRUZIONI DI INSTALLAZIONE TLR04M-350-500 TLR04M-350-500 L&L Luce&Light srl / Via Trescalini, 5 / 36031 Dueville, Vicenza / Italy / T +39 0444 36 05 71 / F +39 0444 59 43 04 E lucelight@lucelight.it / www.lucelight.it...