Advertisement

oisture Sensor
est 4
ARNING
!
Before measuring resistance, be sure to turn power off, and do voltage discharge. (When discharging,
contact the metal plug of power cord with the earth line.)
Failure to follow these instructions can result in death or electric shock.
Trouble Symptom
Measurement Condition
Take 6pin Connector from
the Controller.
Metal or Wire
amping cloth
Table 2. IMC Ratio and isplay Value / Voltage (IMC: Initial Moisture Content)
IMC
70% ~ 40%
40% ~ 20%
10% ~ dried clothes
egree of dryness does not match with dry level.
Turn the dryerÕs power off, then measure resistance.
Short with metal to the 6 pin connectorÕs pin
(Blue Wire) and
Pin (Orange Wire) to controller.
When measuring resistance in electrode load,
is resistance below 1½?
When contacting cloth to electrode:
1. Is the measurement within the range of Table 2
during diagnostic test?
2. Is the measurement within the range of Table 2
when measuring the voltage in the 6 pin connectorÕs
Pin (BLUE wire) and Pin (ORANGE wire)?
Normal Condition
Display Value Voltage (DC) (between 6 Pin terminal
50 ~ 130
130 ~ 20
205 ~ 240
YES
YES
2.5V
2.0V ~ 4.0V
Over 4.0V
60
¥ Check electrode
and harness
connector.
NO
¥ Check harness-
linking connector.
¥ Replace control
NO
and check.
)
Remark
Weight after removing from
washing machine
amp ry
Completely-dried clothes