POWER
Power On the Console
To power on the console:
1. Press and release the PROGRAMME
The console will initially display the software version at the top of
the screen and the serial number of the console at the bottom of the
screen. After approximately 3 seconds, the console will enter the
work screen.
APPLICATION MODE
The 845-AB gives the possibility of working in two different ways
to fit the application. Therefore, the console should be set up and
consequent programming and working features will be dependant
of the chosen mode.
Airblast Mode
This mode is designed to work with Airblast sprayers, mostly
spraying on two sides (left and right) with the possibility to switch
on or off sections in the height. The working width is defined by
the distance between two rows of trees. This mode is called AB
(airblast).
Figure 1: Airblast (AB) principle
-2-L
-1-L
button.
-2-R
-1-R
Working Width
Power Off the Console
To power off the console:
1. While pressing and holding the MINUS
release the PROGRAMME
2. Release the MINUS
button.
The console will save new information (area and volume counters)
to memory before it powers down. Pressing any key during the
power off count down will cancel the shut off function.
Automatic Shutdown
With the Master Switch in the "OFF" position, the console will
automatically shut down after 10 minutes of no inputs (or at the time
specified in the Automatic Shutdown Time setting in the OEM Setup
Mode).
High Clearance / Vineyard Mode
This mode is designed to work with vineyard sprayers that are
spraying horizontally. Several rows are covered and sections can
be switched on or off to adapt the working width. Each section
covers a number of faces. The working width is defined by the
number of faces and the row width.
One or more nozzles can be spraying each face. If all nozzles
spraying on a face are not equal, they should be considered
as a unique nozzle and the total flow has to be set up in the
configuration menu. But all faces have to be sprayed equally. This
mode is called HC (high clearance / vineyard).
Figure 2: High Clearance / Vineyard (HC) principle
Section 1
Section 2
3 Faces
Face
Working Width
button, press and
button.
Section 3
4 Faces
3 Faces
Row Width
98-01611-EN R0
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 845-AB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TeeJet 845-AB

  • Page 1 APPLICATION MODE High Clearance / Vineyard Mode The 845-AB gives the possibility of working in two different ways to fit the application. Therefore, the console should be set up and This mode is designed to work with vineyard sprayers that are spraying horizontally.
  • Page 2: System Setup Mode

    TeeJet Technologies or an authorized dealer. Enter OEM Setup Mode To enter the OEM setup mode both the 845-AB console and Master Switch must be off. Advance to the Next Option Press and hold the PLUS...
  • Page 3 10 gallons, etc. X TeeJet 801 flow meter has a calibration number of 82. X TeeJet 802 flow meter has a calibration number of 21.
  • Page 4 R EFE RE NC E GUI D E Step Display Description Default Flow Meter-> This step is only available if “Flow Meter Installed” is set to “Yes” 10.0 l/ min Flow Sensor and the console is programmed for use with a pressure sensor. Minimum Flow Set the minimum flow capacity for the installed flow sensor.
  • Page 5 Default AB Mode – The flow rate for each section of the sprayer must be input into the 845-AB console so that the necessary adjustments can be made when boom sections are shut off. The console is programmed to treat the left and right boom sections as symmetrical;...
  • Page 6 R EFE RE NC E GUI D E Step Display Description Default Density Establishes the weight per volume setting based on the type of 1.00 fertilizer being used. Water = 1.00. The density value equals Weight of the Solution ÷ Weight of Water. Regulation Valve Instructs the console where the regulating valve is plumbed into Bypass...
  • Page 7: Swath Width

    1 will be displayed. The swath width is displayed on the have been entered, press the GREEN button or the Programme lower right of the console (measured in metres for SI [metric] units). key to return to the Operations mode. Figure 3: Entering swath width presets www.teejet.com...
  • Page 8: Application Setup Mode

    R EFE RE NC E GUI D E Should a different swath preset be desired, press the GREEN button Selecting a Swath Width Preset again to advance to the next swath selection. Continue to press the Once the swath widths are programmed, select the swath width to GREEN button until the appropriate swath preset is displayed.
  • Page 9 X If the indicated speed is too low, a set of larger Tips/Nozzles is required. Known Speed The console will calculate what the No defaul Calculation pressure must be to maintain the target value application rate at the entered speed. www.teejet.com...
  • Page 10: Operation Features

    R EFE RE NC E GUI D E OPERATION FEATURES Feature and Display Description Tank Level Used to show and/or set the actual content level in the tank. This level will decrease by the amount being sprayed. If the minimum tank level has been set to a value greater than zero and the actual level becomes less than the minimum level, a tank alarm will be triggered.
  • Page 11: Alarm System

    ALARM SYSTEM A number of sensor alarms have been included in the 845-AB software. The alarm system is only active with Master on. All audible alarm signals can be cancelled by pressing any button. All alarms are reset when Master is switched off.
  • Page 12 (based on pressure and nozzle type). Tank Level Alarm Current tank level drops below tank Low Priority (1 short beep, repeat every minimum. second). www.teejet.com 98-01611-EN A4LT R0 English-International © TeeJet Technologies 2023...

Table of Contents