  • Page 1 INSTRUCTION MANUAL POWER LINES CDN UNIT LSS-6000 series LSS-INJ6350 MODEL NOISE LABORATORY CO., LTD. 1.09 EDITION AEE00029-00E-0J...
  • Page 2 Noise Laboratory Co., Ltd. shall have no liability for any trouble resulting from the remodeling or modification of this product. In no event shall Noise Laboratory Co., Ltd. be liable for any results arising from the use of this product.
  • Page 3: Important Safety Precautions

    IMPORTANT SAFETY PRECAUTIONS Thoroughly understand the following precautions before use, as they are important matters for handling this unit in safety. 1. As the surge output part of this unit and Lightning Surge Simulator (Models LSS-6000 series) generate high voltage and great electric current (6.6kV 3300A maximum), carefully handle it.
  • Page 4 Memorandum...
  • Page 5: Application Form For Instruction Manual

    When an INSTRUCTION MANUAL is required, fill in the above Application Form and mail or fax it to the following sales department of our company. To: Noise Laboratory Co., Ltd. 1-4-4, Chiyoda, Sagamihara City Kanagawa 229-0037, Japan TEL: +81 (0)42 712 2051 FAX: +81 (0)42 712 2050...
  • Page 6 Memorandum...
  • Page 7: Table Of Contents

    ................12 OW TO CONNECT EQUIPMENT 6-2. H ................. 13 OW TO SET THE TEST CONDITIONS SPECIFICATIONS ....................14 STANDARD ACCESSORIES.................. 15 8-1. S ..................15 TANDARD ACCESSORIES WARRANTY ......................17 MAINTENANCE ....................19 NOISE LABORATORY SUPPORT NETWORK ..........20...
  • Page 8 Memorandum...
  • Page 9: Preface

    In order to obtain the highest performance from your LSS-INJ6350, thoroughly understand the contents of this manual and use as ready reference for operation. Please read the instruction manual of the LSS-6000 series for the details on the operation of the LSS-6000 series Lightning Surge Simulator..
  • Page 10: Appearance Of The Unit And Position Of Serial Number

    5. APPEARANCE OF THE UNIT AND POSITION OF SERIAL NUMBER 5-1. Appearance of the unit ② ① A C L I N E C O U P L I N G D E C O U P L I N G U N I T L S S - I...
  • Page 11: Name Of Each Part And Function

    ⑤ SURGE input terminal (HOT side) Surge input terminal to inject a surge into the AC line. Connect this terminal to the surge output (L1) terminal of the LSS-6000 series Lightning Surge Simulator using the supplied surge input cable. ⑥ SURGE input terminal (GND side) Surge return terminal to inject a surge into the AC line.
  • Page 12 ⑫ Interlock connector 1 Interlock function for safety use. Connect this terminal to the interlock connector of the LSS-6000 series using the attached interlock cable otherwise the surge can not be injected. The internal circuit send zero-cross signal to LSS-6000 series through this connector to synchronize with the LINE INPUT.
  • Page 13: Surge Injection Phase

    5. Appearance of the Unit and Position of Serial Number 5-3. Surge injection phase Hot to inject a surge between L1 and L2 Insert the supplied short plugs into the indicated places with slash lines in the following figure. ※ Insert each short plug securely into the bottom of the each terminal. S .
  • Page 14: How To Connect Equipment

    6. HOW TO CONNECT EQUIPMENT 6-1. How to connect equipment Connect this unit to the LSS-6000 series Surge Simulator, the EUT and the insulation transformer unit as shown in the following figure. We recommend you to use our insulation transformer unit Model: TF series.
  • Page 15: How To Set The Test Conditions

    6. How to connect equipment 6-2. How to set the test conditions The surge injection phase setting part is composed of “surge HOT side setting part” and “surge GND side setting part”. S.HOT.COM is connected to the injection phase (L1, L2, L3 or N) into which the surge is injected by inserting a supplied short plug.
  • Page 16: Specifications

    7. SPECIFICATIONS Specifications of LSS-INJ6350 Items Specifications Combination waveform (※1) Surge waveform Maximum input level 6.6kV Maximum EUT power AC500V 50A (Single phase and three-phase AC) Coupling mode selection Manually selectable Decoupling coil 1.5mH (each line) Line synchronization Detect the phase of AC line function AC100~120V, 200~240V, Approx.
  • Page 17: Standard Accessories

    8. STANDARD ACCESSORIES 8-1. Standard accessories C C C C D D D D B B B B A F F F F G G G G E E E E I I I I J J J J H H H H K...
  • Page 18 8. Standard accessories The following accessories are contained: Quantity A : Accessory bag ······································································· 1 B : Surge input cable [plug: red – red] (0.5m) ································· 1 Surge return cable [plug: green/yellow-green/yellow](0.5m) ········· 1 C : Surge output cable (2m) ························································· 4 D : Surge output cable for PE (2m) ················································...
  • Page 19: Warranty

    9. WARRANTY Servicing terms The following terms are applicable to servicing by Noise Laboratory Co., Ltd., (hereafter referred to as the Company) provided to maintain the intended performance of its products. 1. Scope The following terms shall apply only to products made by the Company.
  • Page 20 9. Warranty Limited warranty Noise Laboratory Co., Ltd. (hereafter referred to as the Company) warrants its products to be free from defects in materials and workmanship under normal use and service for a period of one year from date of delivery. In the event of failure of a product covered by this warranty, the Company will repair the product or may, at its option, replace it in lieu of repair without charge.
  • Page 21: Maintenance

    10. MAINTENANCE When repair, maintenance or internal adjustment of the unit is required, a qualified service engineer takes charge of such work. Maintenance on the user side is restricted to the outside cleaning and functional check of the unit. When checking or replacing the fuse, turn off the switch of the unit and disconnect the plug socket beforehand.
  • Page 22: Noise Laboratory Support Network

    Noise Laboratory or your nearest sales agent of Noise Laboratory. When the product is returned to Noise Laboratory, write the state of the trouble, contents of your request, model name and serial number in a repair order, and pack the product and repair order sheet in the former package of equivalent suitable for transit and send them back.
  • Page 23 Noise Laboratory Co., Ltd. PRINTED IN JAPAN...