Hansford sensors HS-429 Manual

Hansford sensors HS-429 Manual

Vibration trip

Advertisement

Quick Links

HS-429 Vibration Trip Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HS-429 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hansford sensors HS-429

  • Page 1 HS-429 Vibration Trip Manual...
  • Page 2 HS-429 USER GUIDE CONTENTS 1. SAFETY INSTRUCTIONS ------------------------------------------------------------------------- 2 2. FUNCTIONS AND FEATURES ------------------------------------------------------------------- 2 3. INSTALLATION -------------------------------------------------------------------------------------- 2 4. ELECTRICAL CONNECTION -------------------------------------------------------------------- 3 5. SETTINGS ---------------------------------------------------------------------------------------------- 3 6. MEASUREMENT RANGE ------------------------------------------------------------------------- 3 7. SWITCHING AND BEHAVIOUR ---------------------------------------------------------------- 4 8. OPERATING AND DISPLAY ELEMENTS ---------------------------------------------------- 5 9.
  • Page 3 HS-429 USER GUIDE An instruction is indicated by "►": Example: ► Check whether the unit operates correctly. Important note Non-compliance can result in malfunctions or interference Information Supplementary note SAFEY INSTRUCTIONS • Please read the product description prior to set-up of the unit Ensure that the product is suitable for your application without any restrictions •...
  • Page 4 HS-429 USER GUIDE ELECTRICAL CONNECTION The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. SETTINGS RMS Set Effective value of the switching threshold, defining the limit value of the vibration velocity...
  • Page 5 HS-429 USER GUIDE SWITCHING OUTPUT BEHAVIOUR 1: Time delay after the switching threshold has been exceeded 2: Time delay after the switching threshold has been exceeded 3: Switch-off 4: Switching threshold 5: Delay = vibration velocity t = time Implementation of the time delays...
  • Page 6 HS-429 USER GUIDE OPERATING AND DISPLAY ELEMENTS 1) locking ring 2) setting rings (manually adjustable after unlocking) 3) LED green: voltage supply 4) M8 process connection 5) LED yellow: lights when switching threshold and time delay are exceeded 6) setting marks...
  • Page 7 HS-429 USER GUIDE MAINTENANCE, REPAIR AND DISPOSAL The operation of the unit is maintenance-free. It is not possible to repair the unit. After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations.

Table of Contents