2. SPECIFICATIONS
Electric fan heaters for industrial applications. selectable heat settings with thermostat control. A totally dry heat with no condensation, no gas, no
fumes, so no smell. Ideal for workshops, garages etc.
Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EH2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EH3300
Voltage/frequency:. . . . . . . . . . . . . . . . . . . . . . 230V ~50Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V ~50Hz
Power rating:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2000W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3300W
settings: . . . . . . . . . . . . . . . . . . . . . 650W - 1300W - 2000W . . . . . . . . . . . . . . . 40W(fan only) - 1650W - 3300W
Dimensions: . . . . . . . . . . . . . . . . . . . . . 197 x 210 x 313mm . . . . . . . . . . . . . . . . . . . . . . . . . 250 x 250 x 398mm
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6kg
fuse:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30A
Note: EH3300 requires a 30A fuse. Contact a qualified electrician to ensure that a suitably rated supply is available.
We recommend that you discuss the installation of an industrial round pin plug and socket with your electrician.
IMPORTANT! this unit is designed to raise the ambient temperature of an entire room, the temperature of the air coming out of the front of the
heater will be warmer than the general temperature of the room, but there may not be significant increase due to the large volume of air passing
over the element. for the same reason, the element is hot during operation but does not visibly glow. the room temperature depends on room
size, insulation and the ambient temperature, which will increase as the room gets warmer.
3. OPERATION
3.1
Position heater in an upright position on a firm surface and at a safe distance
from any obstructions, flammable substances etc, see fig 1.
3.2
connect the heater to a suitable mains supply.
(for EH3300, see note in specifications above).
3.3
set the thermostat dial to the maximum setting (fully clockwise).
3.4
the fan heater will switch on when the power setting selector is set to one of the
three power settings (fig 2, fig 3).
NOTE: It will take up to three minutes for the heater to reach optimum temperature.
3.5
once the room reaches the required temperature, turn the thermostat dial slowly
counter-clockwise until you hear the thermostat click, this will maintain the room
temperature at this setting. the fan will continue to operate until the power switch
is turned to the off position.
3.6
for fan only operation on model EH2000 select first power setting but set
thermostat to minimum.
1st power setting (1 bar 650W)
off
Power Switch
4. MAINTENANCE
WARNING! Before attempting any maintenance ensure the unit is unplugged from the mains power supply and that it is cool.
4.1. clean the heater with a soft dry cloth. DO NOT use abrasives or solvents.
4.2. Periodically check the heater grille to ensure it is not blocked.
no other maintenance is necessary. If you experience a problem with your heater or if the power lead or plug is damaged contact your local
authorised service agent for repair. DO NOT dismantle or tamper with the heater as this may be dangerous and will invalidate your warranty.
NOTE: It will take up to three minutes for the heater elements to reach optimum temperature. This is normal and not a fault.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: no liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
fig 2
2nd power setting (2 bar 1300W)
3rd power setting (3 bar 2000W)
EH2000
Thermostat
Sole UK Distributor, Sealey Group,
Kempson Way, suffolk Business Park,
Bury st. Edmunds, suffolk,
IP32 7Ar
fig 1
off
Power Switch
Original Language Version
fig 3
1st power setting (fan only 40W)
2nd power setting (1 bar 1650W)
3rd power setting (2 bar 3300W)
EH3300
Thermostat
www.sealey.co.uk
01284 757500
Web
sales@sealey.co.uk
01284 703534
email
EH2000, EH3300
Issue: 4 - 21/10/09

Advertisement

loading

This manual is also suitable for:

Eh2000