Zico ZI-9983 Operating	 Instruction

Zico ZI-9983 Operating Instruction

Ac/dc 400a clamp meter

Advertisement

Quick Links

ZI-9983
OPERATING INSTRUCTION
AC/DC 400A Clamp Meter
Ω
www.zicotech.com

Safety

International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user must refer
to the manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous
voltages may be present
Double insulation
SAFETY NOTES
Do not exceed the maximum allowable input range of any function
Do not apply voltage to meter when resistance function is selected.
Set the function switch OFF when the meter is not in use.
WARNINGS
Set function switch to the appropriate position before measuring.
When measuring volts do not switch to current/resistance modes.
When changing ranges using the selector switch always disconnect the test leads from
the circuit under test.
Do not exceed the maximum rated input limits.
CAUTIONS
Improper use of this meter can cause damage, shock, injury or death. Read and understand
this user manual before operating the meter.
Always remove the test leads before replacing the battery.
Inspect the condition of the test leads and the meter itself for any damage before operating
the meter. Repair or replace any damage before use.
Use great care when making measurements if the voltages are greater than 25VAC rms or
35VDC. These voltages are considered a shock hazard.
Remove the battery if the meter is to be stored for long periods.
Always discharge capacitors and remove power from the device under test before
performing Diode, Resistance or Continuity tests.
 Voltage checks on electrical outlets can be difficult and misleading because of the
uncertainty of connection to the recessed electrical contacts. Other means should be used
to ensure that the terminals are not "live".
 If the equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Function
A
V DC, V AC

Input Limits

Maximum Input
400A DC/AC
600V DC/AC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZI-9983 and is the answer not in the manual?

Questions and answers

Summary of Contents for Zico ZI-9983

  • Page 1 International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. ZI-9983 This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation...
  • Page 2 Frequency, Resistance, Diode, Continuity , 250V DC/AC 400.0mVAC ± (1.5% + 30 digits) Capacitance Test 4.000 VAC AC Voltage 250V DC/ AC Temperature (℃/℉) 40.00 VAC (50-400Hz) ± (1.5% + 5 digits) 400.0 VAC ± (2.0% + 5 600.0 VAC digits 400.0 Ω...
  • Page 3 II, Pollution Degree 2. Category II includes local level, 4. Touch the test probes to the diode under test. Forward voltage will indicate 0.4V to 0.7V. Reverse voltage will indicate “OL”. Shorted devices will indicate near 0mV and an open appliance, portable equipment, etc., with transient device will indicate “OL”...
  • Page 4 1. Touch the probe tip to the hot conductor or insert into the hot side of the electrical outlet. 2. If AC voltage is present, the detector light will illuminate. NOTE: The conductors in electrical cord sets are often twisted. For best results, rub the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor.