Download Print this page

Advertisement

Quick Links

User Guide
SPECIFICATIONS
PRECAUTIONS
PREPARATION
STAR N04
ELECTRICAL
Current dissipation : 110 mA(Colored:70mA)
Power Consumption : 1.32 W(Colored:0.84W)
Operating power : DC 12V
Maximum serial connection : 50 modules
Electronic dimming control supported
PHYSICAL
Use precautions to avoid damages to the product or injuries of users. Any actions against following contents will cause serious
issues such as malfunction, electric shock, or burn.
DC12V
USE DC12V ONLY
AC INPUT
DO NOT USE AC INPUT
Do not cut or rejoion wires while product
is connected wth live power source
Avoid performing installation under rain or
high humidity for outdoor use
Do not use the product under circumstances
listed below
- High temperature spots over 60˚C (140˚F)
- Spots draw extreme moisture or dust
- Spots have corrosive gas or highly effectied
by electromagnetic field
TOOLS REQUIRED
Wire Stripper, Drill, Screw Driver, Wiper
PREPARE CHANNELS
1. Clean moisture and dust inside
1. Wipe out dust, water, and oil inside. 3M tape will come off easily if product is mounted on uncleaned surfaces.
2. Make holes for wires from modules to SMPS.
3. Without bushins, wires will easily be cut and short-circuit will occur.
*Use white paint inside the channels for better reflection
DAEHANTRANS CO.,LTD
#7-11 Songdo-Dong, Yeonsu-Gu, Incheon, Korea
Tel. +82 32 858 0491 Fax. +82 32 832 8421 enquiry@daehantrans.com / www.daehantrans.com
THERMAL
Cooling : Ambient air
Maximum operating temperature : 50˚C
Minimum operating temperature : -20˚C
Maximum storage temperature : 60˚C
Minimum storage temperature : -20 C
Nonpolar
Input Connection
double sided tape
SUPPLIES REQUIRED
Wire Nuts, Cable Ties, IDC Connectors, VCTF(PLTC) Cable,
(Optional : Silicon and Screws)
2. Make holes
Epoxy Molding
Do not perform actions listed below
- Alter or modify
- Touch LED lamps with sharp objects
- Put glue or silicon over the LED lamps
Maximum driver quantity per serial
connection is limited. Failure causes overload
of current and damages to the product
Refer to 'WIRE THICKNESS' table to use proper
wire thickness between SMPS and the first
LED module
Failure will cause dimmed output
Cable length between SMPS and the first LED
module is limited. Refer to 'CONNECTION
WITH POWER SUPPLY' on page 2
3. Use bushing to protect wires
1

Advertisement

loading

Summary of Contents for FARD lighting STAR N04

  • Page 1 STAR N04 User Guide SPECIFICATIONS ELECTRICAL THERMAL Current dissipation : 110 mA(Colored:70mA) Cooling : Ambient air Power Consumption : 1.32 W(Colored:0.84W) Maximum operating temperature : 50˚C Operating power : DC 12V Minimum operating temperature : -20˚C Maximum serial connection : 50 modules Maximum storage temperature : 60˚C...
  • Page 2 STAR N04 User Guide LAYOUT DENSITY Use recommended length for pitch between each module to achieve optimum lighting output while maintaining lowest unit cost. Failure or misplacing will cause dimmed spots or uneven appearance of light on the surface. GUIDELINES...
  • Page 3 STAR N04 User Guide INSTALLATION GUIDE 1. DETERMINE LAYOUT MATERIAL ESTIMATE Attention to : John Doe Page 1 of 1 Stroke Width 1000 mm Channel Depth STAR C04 WHITE x 143 Information NUMBER OF SET Model Color Quantity Power Supply...
  • Page 4 STAR N04 User Guide TROUBLE SHOOTING Entire sign or leg does not light Check connection from power supply lead to first module. Make sure polarity of connec- after complete installation. tions made at the power supply lead and any jumper wire is correct. Power supply outputs should be connected red-to-red and white-to-white.