Do not use for • Keep the area around the pulse line filter free of combustible any other purpose. Oriental Motor Co., Ltd. is not responsible for materials in order to prevent fire or a skin burn(s).
Page 8
Names and functions of parts System configuration Controller Driver Connection cable between Input circuit selector switch driver and controller (Factory setting: ON) Controller connecting terminal 24 VDC Cutouts for installation Connect to GND Pulse line filter 24 VDC connecting terminal Connection cable between Connect using the provided [Terminal tightening torque:...
Page 9
Connection Connection example of ARL Series, AS Series and ASC Series • VCS05-11: When using the open-collector output type controller Connect using the provided connector cable. Pulse line filter VCS05-1 ARL/AS/ASC Series Driver Controller ∗3 24 VDC ∗4 +24 V ∗4 ARL/AS Series: CN4 ASC Series: CN3...
Page 10
• VCS05-11: When using the line driver output type controller Connect using the provided connector cable. Pulse line filter VCS05-1 ARL/AS/ASC Series Driver Controller ∗3 24 VDC ∗4 +24 V ∗4 ARL/AS Series: CN4 ASC Series: CN3 +24 V +24 V Vcc+24 V 165 Ω...
Page 11
Connection example of RK Series • VCS05-21: When using the open-collector output type controller Connect using the provided connector cable. Pulse line filter VCS05-2 RK Series Driver Controller ∗2 24 VDC ∗4 CW pulse (5 to 24 VDC) 165 Ω 165 Ω...
Page 12
The pin arrangement is shown as viewed from the solder side. • Please contact your nearest Oriental Motor office for further information. is a registered trademark or trademark of • Please contact your nearest Oriental Motor office for further information.