Order # 60210101
Part # VaL-1-LB3-CP3-t3-MV-LVd-7Pr
60211101
VaL-1-LB3-CP3-t5-MV-LVd-7Pr
60212101
VaL-2-LB3-CP3-t3-MV-LVd-7Pr
60213101
VaL-2-LB3-CP3-t5-MV-LVd-7Pr
60214101
VaL-3-LB3-CP3-t3-MV-LVd-7Pr
60215101
VaL-3-LB3-CP3-t5-MV-LVd-7Pr
60216101
VaL-4-LB3-CP3-t3-MV-LVd-7Pr
60217101
VaL-4-LB3-CP3-t5-MV-LVd-7Pr
Use and Care GUide
Led Versa area LiGht instaLLatiOn
120-277V 50/60hz 100W/80W/60W 150W/120W/100W 200W/180W/150W 300W/240W/200W
Package contents
Description
Quantity
Fixture
1
Fixture
Shorting Cap
1
nOte: Keep your receipt and these instructions for proof of purchase.
nOte: To avoid possibility of electrical shock or fire, the installation personnel must have professional electric knowledge. Please wear gloves to avoid injury before installation. If any
smoke or spark of the wire happened, please turn off the power immediately and notify relevant personnel.
WarninG: Shut off the power at the circuit breaker or fuse panel before removing the old fixture, ballast, or fluorescent tubes. Do not use any electric generator to test this LED light.
Please abide by related country, regional and local law and regulations when installing this fixture. Please turn off the power before installation or maintenance. Proper earth grounding is
required to ensure safety. After installation, level the light to point downward. Please check if there is any damage during shipping. If so, please contact manufacturer right away. Please read
the installation instruction carefully to check whether all the accessories are present. After confirmation, Install the fixture according to installation steps.
If you are unfamiliar with electrical installations, we recommend you contact a qualified electrician to do the installation.
instructions
1. This product is dimmable.
2. Three dimming functions are available in this LED light.
• Constant current can be achieved by 0-10VDC or 1-10VDC dimming.
• PWm signal dimming.
• Variation of resistance unit dimming (Please choose the appropriate dimming way according to your needs. You can also choose not to use this function).
3. Choose the wire connection ways, dimming ways and installation ways according to your needs and the led fixture purchased.
Wiring Diagram
oPtional brackets anD installation instructions
There are 5 optional brackets for this fixture. The following are our VersaArea fixtures with
different brackets.
Black/Brown:ACL
Green/Yellow
As for the wire color
Dim+
White/Blue: ACn
of DIm+ and DIm-,pls
check the lamp label.
Dim-
installation instructions With Different brackets
1
SLIP FITTEr Arm mounT (SFA)
• remove the bracket mounting screws on the fixture and pass the wires
through the bracket.
• Install the bracket on the fixture.
2
ADjuSTABLE STrAIGHT Arm mounT (ASA)
• remove the bracket mounting screws on the fixture,open the side lid of
bracket and pass the wires through the bracket.
• Install the bracket on the fixture, then cover the side lid and tighten it.
TrunnIon Arm mounT (TrA)
3
• remove the bracket mounting screws on the fixture and pass the wires
through the bracket.
• Install the bracket on the fixture.
QuICK Arm mounT (QmA)
4
• remove the bracket mounting screws on the fixture and pass the wires
through the bracket.
• Install the bracket on the fixture.
Certification # VaL-1-LB3-CP3-t3-MV-LVd-7Pr
5
WALL mounT BrACKET (WmB)
VaL-1-LB3-CP3-t5-MV-LVd-7Pr
VaL-2-LB3-CP3-t3-MV-LVd-7Pr
• Secure Wall mount Kit to Fixture with (2) bolts (provided).
VaL-2-LB3-CP3-t5-MV-LVd-7Pr
• WmB must be used in conjunction with ASA or QmA mount.
VaL-3-LB3-CP3-t3-MV-LVd-7Pr
VaL-3-LB3-CP3-t5-MV-LVd-7Pr
VaL-4-LB3-CP3-t3-MV-LVd-7Pr
VaL-4-LB3-CP3-t5-MV-LVd-7Pr
installation of leD light
SLIP FITTEr Arm mounT (SFA)
1
• Connect the wire correctly and put the wires into pole. Then fasten the
locking bolts between slip fitter and the pole.
• Loosen the fixing bolts and adjusting bolts, align the fixture to required angle.
Tighten adjusting bolt and fixing bolts after the angle is confirmed.
nOte: Adjustable angle is 0~+/-90°.
Shorting Cap
2
ADjuSTABLE STrAIGHT Arm mounT (ASA)
• Fix the ASA bracket to the square pole with bolt, open the side lid of ASA
bracket, pull the wire into junction box, and connect the wires correctly.
• Put the connected wires into the junction box, then cover the junction box.
nOte: notice: Adjustable angle range is 0-35°.
For round pole installation, follow the previous steps, but remove the silicone
plate when installing on a round pole.
TrunnIon Arm mounT (TrA)
3
• Drill holes on the wall as shown in Figure.
• Knock the expansion bolts into the wall.
• Connect the fixture to the bracket and tighten the screws; connect the wires
properly and put them into junction box.
nOte: Adjustable angle is 0-90°.
SFA
4
QuICK Arm mounT (QmA)
ASA
• Lock the bracket on the fixture. (m8*25 mm screws. m8 washers).
TrA
• Affix the mount to the square pole with bolts, open the bottom cover of the
mount bracket, pull the wires into the junction box, and connect the wires
QmA
correctly (refer to area light installation instructions for wiring diagram).
For round pole installation, follow the previous steps, but remove the silicone
plate when installing on a round pole.
WmB
oPtional mounting orDering guiDe
order #
Part #
70336101
VAL-SFA
70338101
VAL-ASA
70337101
VAL-TrA
70335101
VAL-QmA
70339101
VAL-WmB
±90
light
SFA Bracket
Adjusting Bolt
Locking Bolt
Support
light
ASA Bracket
light
35°
Bolt
ASA Bracket
Side lid
Side lid
junction box
round pole
square pole
square pole
77
77
±90°
10
TrA Bracket
Expansion Bolt
m8 Screws
Bracket
bracket
bracket
Bolt
Lamp
bottom cover
junction box
round pole
remove Silicon Plate
Square pole
(sold separately)
Description
VersaArea 2 3/8" Slip Fitter Arm mount
VersaArea Adjustable Straight Arm mount
VersaArea Trunnion Arm mount
VersaArea Light Quick Arm mount
VersaArea Wall mount Bracket
instructions for Photocell
When the photocell function is required,photocell should be installed on the back of light;
When it's not required, shorting cap should be installed on the back of light.
L/live wire: Black\Brown;
n/null wire: White\Blue;
Ground wire: Green\Yellow-green.
instructions for motion sensor
1. unscrew the 1/2 plug.
2. For products with motion sensor function, the induction module should be installed on the
socket.
Support
correlateD color temPerature (cct) anD Wattage aDjustments
CCT and/or Wattage adjustment.
1
• unscrew the 3/4 plug.
• Adjust the integrated switch for CCT & Wattage adjustable to get the desired CCT and
Silicone plate
Wattage according to the label on the fixture.
• replace and tighten the 3/4 plug.
CCT
3/4 plug
5K 4K 3K
light
3/4 plug
Lamp
WarninG: Carefully read and understand the information given in this manual before beginning the assembly and installation. Failure to do so could lead to electric shock, fire, or
other injuries which could be hazardous or even fatal. • Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker.
nOtiCe: This device complies with Part 15 of the FCC rules. operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
reorient or relocate the receiving antenna, increase the separation between the equipment and the receiver, connect the equipment into an outlet on a circuit different from that to which
the receiver is connected, and consult the dealer or an experienced radio/TV technician for help.
• Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
See website for Warranty, Troubleshooting or Care and Cleaning details at www.ETiSSL.com.
Questions, problems, missing parts? Call ETiSSL Customer Service 8 a.m. - 5 p.m., CST, monday - Friday
1-855-eti-ssli (1-855-384-7754) www.etissl.com
Photocell
Shorting cap
Socket
1/2 plug
motion Sensor
Wattage
3/4 plug
150W 120W 100W
CCT & Wattage Settings
5K 4K 3K
150W 120W 100W
Need help?
Do you have a question about the VAL-1-LB3-CP3-T3-MV-LVD-7PR and is the answer not in the manual?
Questions and answers