The Thin Door/Window Contact (2GIG‐DW14‐433) is designed for use 
on doors, windows, and other objects that open and close. It 
communicates with the control panel using the 433 MHz frequency. 
When the magnet (which is mounted near the sensor) moves away 
from or closer to the door contact's sensor, signals are transmitted to 
the control panel. The door contact also has an external input that 
accepts connections from Normally‐Closed (NC) dry contact devices. 
For added protection, it is also equipped with a cover tamper.
Figure 1
Thin Door/Window Contact—Sensor and Magnet
A
Thin Door/Window Contact Sensor
B
Thin Door/Window Contact Magnet
C
Alignment Marks on Sensor
D Alignment Arrow on Magnet

Box Contents

Verify that the package includes the following:
• 1—Thin Door/Window Contact
• 1—Rare Earth Magnet
• 2—Phillips Head Screws
• 2—3‐Volt (3V) Lithium Coin Batteries
• 2—Adhesive Foam Tape
• 1—12 in (30 cm) Wire Lead

Testing the Thin Door/Window Contact

Before mounting the door contact at the desired location, perform a 
walk test to verify that it can establish good Radio Frequency (RF) 
communications with the control panel. 
NOTE:
To fully test the Thin Door/Window Contact, see the 
control panel's Installation and Programming Guide.

Mounting Guidelines

Use these guidelines when installing the door contact for internal 
switch usage:
• Mount Sensors within 100 ft (30 m) of the Control Panel. 
Although the transmitter may have a range of 350 ft (106.7 m) 
open air, the sensor location can have a significant effect on 
range. In open/unobstructed situations, the transmitter range 
may be greater. In adverse wireless conditions, changing the 
sensor orientation may lead to improved range. 
• Mount Sensors at Least 4.7 in (12 cm) Above the Floor. 
Placing sensors slightly above floor level helps to minimize 
possible sensor damage. 
• Single vs. Double Door Installation. For single‐door 
installation, mount the sensor on the door frame and the 
magnet on the door. For double‐door installation, mount the 
sensor on the least‐used door and the magnet on the most‐
used door.
• Do Not Expose Sensors to Moisture or Extreme Temperature. 
It is best to mount sensors in a dry location where the 
operating temperature do not exceed 32° to 120° F (0° to 49° 
C).
• Keep Sensors and Magnets Away from Metal/Metallic 
Surfaces. To keep sensors and magnets away from metal or 
metallic surfaces (for example, foil wallpaper), it is 
recommended that you use spacers (not included). You should 
also avoid mounting sensors in areas where there is a large 
quantity of metal or electrical wiring (for example, near a 
furnace or in a utility room).
• Align Magnet with Sensor. Make sure the alignment arrow on 
the magnet points to the center alignment mark on the sensor 
(see Figure 1   Thin Door/Window Contact—Sensor and 
Magnet).

Mounting the Thin Door/Window Contact

Use the figure below as a guideline when mounting the door contact. 
In step 7 below, you have the option to mount the door contact with 
an external input wire for an NC dry contact device. 
Figure 2 Thin Door/Window Contact—Backplate and Battery Compartment
A
Access hole for external input wire (on backplate)
B
Top and bottom mounting holes (on backplate)
C
External input wire jack (on sensor)
D Tamper switch (on sensor)
E
3‐Volt (3V) lithium coin battery compartments (on sensor)
F
Metal clips for removing batteries (on sensor)
To mount the door contact:
At the top of the sensor, press down on the clip to unlock the 
1
sensor's backplate. Then, gently pull down on the backplate to 
remove it. 
On the backplate, drill‐through top and bottom mounting holes if 
2
needed (see Figure 2  Thin Door/Window Contact—Backplate and 
Battery Compartment). 
Holding the backplate location, place the bottom mounting hole 
3
as follows:
• Single Door Installation. At the desired location on the door 
frame.
• Double Door Installation. At the desired location on the least‐
used door.
Copyright © 2015 Nortek Security & Control LLC
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2GIG-DW14-433 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for 2gig Technologies 2GIG-DW14-433

  • Page 1 2GIG-DW14-433 THIN DOOR/WINDOW CONTACT INSTALLATION INSTRUCTIONS magnet on the door. For double‐door installation, mount the  sensor on the least‐used door and the magnet on the most‐ The Thin Door/Window Contact (2GIG‐DW14‐433) is designed for use  used door. on doors, windows, and other objects that open and close. It  • Do Not Expose Sensors to Moisture or Extreme Temperature.  communicates with the control panel using the 433 MHz frequency.  It is best to mount sensors in a dry location where the  When the magnet (which is mounted near the sensor) moves away  operating temperature do not exceed 32° to 120° F (0° to 49°  from or closer to the door contact’s sensor, signals are transmitted to  the control panel. The door contact also has an external input that  • Keep Sensors and Magnets Away from Metal/Metallic  accepts connections from Normally‐Closed (NC) dry contact devices.  Surfaces. To keep sensors and magnets away from metal or  For added protection, it is also equipped with a cover tamper. metallic surfaces (for example, foil wallpaper), it is  Figure 1 Thin Door/Window Contact—Sensor and Magnet recommended that you use spacers (not included). You should  also avoid mounting sensors in areas where there is a large  quantity of metal or electrical wiring (for example, near a  furnace or in a utility room). • Align Magnet with Sensor. Make sure the alignment arrow on  the magnet points to the center alignment mark on the sensor  (see Figure 1   Thin Door/Window Contact—Sensor and  Magnet). Mounting the Thin Door/Window Contact Use the figure below as a guideline when mounting the door contact. ...
  • Page 2 Thin Door/Window Contact | Installation Instructions To minimize the risk of potential sensor damage,  Specifications IMPORTANT: always mount the sensor at a minimum height of 4.7 in (12  Wireless Signal Range 350 ft (106.7 m), open air, with Wireless  cm) from the floor.  Control Panel Code Outputs Alarm; Alarm Restore; Supervisory; Low  Using the two (2) Phillip Head Screws (provided), secure the  Battery; External Alarm; External Restore;  backplate the door (or door frame).  Tamper; Tamper Restore Ensure that the alignment arrow on the magnet is lined up with  Transmitter Frequency 433.92 MHz (crystal controlled) the middle mark on the sensor (see Figure 1  Thin Door/ Unique ID Codes Over one (1) million different code  Window Contact—Sensor and Magnet).  combinations Supervisory Interval 70 minutes Use the adhesive (provided) to secure the magnet as follows: External Input Accepts N/C dry contact devices • Single Door Installation. On the door. Magnet Dimensions (L x W x H) 1.3 x 0.435 x 0.312 in (3.3 x 1.1 x 0.79 cm) • Double Door Installation. On the most‐used door. Magnet Type Rare Earth The magnet must be no more than 0.4 in (1 cm) ...

Table of Contents