Page 2 TABLE OF CONTENTS Introduction Page 4 General Page 4 Attention Warranty Versions Operating instruction for AB version Page 5 Function of remote control Ignite apparatus Technical data Operating instruction for HB version Page 7 Switching on the unit Switching off the unit Installation instruction for flue version Page 7...
Page 3 We hope you really enjoy the warmth of your new gas fire Read these instructions carefully before install- ing and starting to use the gas fire. Keep these instructions in a safe place. Always provide the following in- formation if the gas fire breaks down: type and serial number.
Page 4 2. Operating instruction for AB version Operating buttons and other functions for the gas control block GV60 (A), the G6R H4S1 (B) remote con- trol and the G6R-R4A3 (C) hand transmitter receiver. Ensure that the batteries have been installed correctly in the remote control and battery holder/signal receiver. NOTE: do not use any screwdrivers or similar when fitting the batteries.
Page 5 Warning! You must ascertain whether gas can be smelled around the unit before switching it on. Some gases are heavier than air and can be found at floor level. You should therefore also determine whether you can smell gas at floor level. Failure to follow the instructions below exactly may lead to damage to personal possessions and may lead to personal injury or even death.
Page 6 Setting first period of heating. Press the button B4 (3x) until P 1 and appears on the display. Press button B4 for slightly longer until the start time begins to flicker and appears and set the time for the start of the first period of heating by means of the buttons B1and B2 ;...
Page 7 3. Operating instruction for HB version. Operating buttons and other functions of the gas control block BM 733 3.1 Switching on the unit Open the gas shut-off cock that has been installed in the gas pipe to the unit. •...
Page 8 5. Fitting the cast iron construction (in the event of service) Hang the u shaped key in the front at the bottom to the side. Then screw in one of the longer wing nuts • loosely above. The connection between the second side and the front panel takes place in the same way. •...
Page 9
Page 9 Log in the middle. Air supply must be open...
Page 10 7. Outlet protection The unit has been fitted with a thermal outlet protection that will switch off the pilot should a leak occur in rela- tion to the combustion gases from the draught limiting device. The outlet protection must never be disabled. Operation: The sensor device is a thermostat that will open an electronic contact when a certain temperature is reached.
Page 12 Adjustable wall bracket Roofing sheet, sloping at 5-30° Concentric pipe Roof pass-through Universal mounting plate Lead roof plate 20-45° 12.1 Possibilities for connecting concentric flue system Indirect wall pass through (see page 23 diagrams 1 and 2). Always fit a length of X=1 metre vertical on the apparatus and then directly after this a bend of 90° with a length Y (min) wall pass through on this.
Page 13
Page 13 Mounting using the roof vent flange option The flue terminal can be located at any random place on the roof face (supply and exhaust in identical pressure areas) and must meet the applicable rules and regulations. * A roofing sheet for a flat roof or a roofing sheet lead for sloping tiled roofs can be used for a watertight duct. Use various bends, if required, for the slope.
Page 14
Page 14 13. Installation instructions for the cast iron Beverly unit • Hang the u shaped groove on the front on the lowest screw in the side and loosely attach one of the longer wing nuts. • The connection between the second side and the front takes place in the same way.
Page 15
Page 15 • Introduce the combustion unit from the upper part of the housing, push it over the wing nuts mentioned above and screw in firmly. The inset piece must be pushed as far forwards as possible. • Put the top plate back in position. •...
Page 16
Page 16 14. Installation instructions for the cast iron Brookfield/ Coventry unit • Hang the u shaped groove on the front on the lowest screw in the side and loosely attach one of the longer wing nuts. • The connection between the second side and the front takes place in the same way.
Page 17
Page 17 • Introduce the combustion unit from the upper part of the housing, push it over the wing nuts mentioned above and screw in firmly. The inset piece must be pushed as far forwards as possible. • Put the top plate back in position. •...
Page 18 15. Additional instructions for the Mertik Maxitrol GV60 and the remote control: Ensure that the fuel supplied to the unit is clean and free from particles and moisture. Before a gas supply pipe (new or existing) is connected to the main gas pipe at the gas meter and to the gas control block of the unit, clean and dry compressed air should be blown through it.
Page 19
Page 19 Do not extend the thermocouple supplied to the pilot set Extending the thermocouple beyond this limit will lead to a reduction in voltage. This may, in turn, lead to the magnetic coil not being activated. Prevent leakage of the ignition spark to parts of the installation other than the ignition rod at the pilot.
Page 20 Problems and possible solutions to them Please check first of all whether all guidelines were followed before attempting to solve any problems with the apparatus. WARNING: Solving problems with your unit, whether gas related or electrical must always be carried out by a qualified technician SYMPTOM TE ONDERNEMEN AKTIE...
Page 21
Page 21 Problems and possible solutions to them, continued... SYMPTOM ACTION TO BE TAKEN The main burner goes out when 1. This can be a normal effect of the thermostat. (AB) the apparatus is warm. Check whether the pilot flame can heat the thermocouple sufficiently. If the pilot flame is too small then the gas pipe or the pilot flame adjustment must be checked.
Page 25 Important tips for heating with gas-fired or wood-fired stoves and fireplaces. Prevent discolouration of walls and ceilings! There are always dust particles in the air in every living space, even if it is regularly vacuumed! These particles are clearly visible in rays of sunlight and they will not bother you as long as the concentration of particles in the air remains low.
Page 26
Page 26 GUARANTEE CONDITIONS All appliances are supplied under a guarantee against material and manufacturing errors. The guarantee is limited to a maximum of the supply of a replacement component and only applies if the instructions for installation and use enclosed with the appliance have been followed, and if the product is being used under normal conditions in the dealer’s assessment.
Need help?
Do you have a question about the Brookfield S/CC and is the answer not in the manual?