Page 2
This user’s manual outlines installation, operating, maintenance, and troubleshooting details vital to the sustained performance of your system. If your system is altered at the site of operation or if the feed water conditions change, please contact your distributor to determine the proper recovery for your application.
COMPONENTS AND FUNCTIONS 1. Exhaust Knob 9. Frequency Display 2. Discharge Valve 10. Keys 3. Back Cover 11. AC 220/110 4. Front Cover 12. Level 5. Suction Valve 13. Contol Signal 6. Pump Head 7. Back Tubing Jack * Make sure dosing pump is the 8.
Page 5
FLOW ADJUSTING AND KEY SETTINGS • Wire the dosing pump into th RO pump motor so • Brown + Power (Red + Blk) the dosing pump will only run when the RO is on. • Blue + Common (White) • Yellow Green Stripe + Ground •...
Page 6
DIMENSIONS AND CAPABILITY NOTE: If the pump head has no exhaust knob, unscrew the nut on the discharge valve to exhaust.
INSTALLATION Chemicals Tank Notice: To prevent precipitation, keep foot valve elevated to have a 20mm clearence above the bottom of the tank.
Page 8
INSTALLATION CONTINUED • One end of back tubing inserted into • Put the nut and clasp over the tubing the head, the other end put into the • Put the tubing into the nozzle hard chemical tank Tubing, Nut , and Nozzle comes pre-assembled. Check valve After handling solutions chlorine, antifoulant, etc.
Page 9
This warranty gives you specific legal rights and you may have other legal rights which vary from state to state. CRYSTAL QUEST assumes no ®...
IMPORTANT NOTES Your dosing system can enhance the effectiveness of your water filtration system, making it more efficient and easier to maintain. Use it during pre-treatment, primary treatment, or post-treatment to control pH levels, eliminate bacteria & viruses, reduce chlorine, or other tasks related to water treatment depending on your specific needs.
Need help?
Do you have a question about the CQE-DS-06001 and is the answer not in the manual?