SERVICE MODE LIST This unit is provided with the following SERVICE MODES so you can repair, examine and adjust easily. To enter to the SERVICE MODE function, press and hold both buttons simultaneously on the main unit or on the main unit and on the remote control for more than a standard time in the appropriate condition.
WHEN REPLACING EEPROM (MEMORY) IC If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to ensure correct data settings while making reference to TABLE 1. IN IT Table 1 CONFIRMATION OF INITIAL DATA Enter DATA SET mode by setting VOLUME to minimum.
SERVICING FIXTURES AND TOOLS JG176 2007 SD DTV Rom Disc JG205 JG206 Flash UP-Date Soft Disc Serial Communication Change JIG Ref. No. Part No. Parts Name Remarks Serial Communication Connect the set to personal computer JG205 APJG205000 Change JIG Up-Date of the Firmware JG206 APJG206000 Flash UP-Date Soft Disc...
ELECTRICAL ADJUSTMENTS 1. ADJUSTMENT PROCEDURE FUNCTION FUNCTION OSD H CONT.CENT OSD C CONT.MAX circuits or replacing electrical parts or PCB assemblies. CUT OFF CONT.MIN H.POSI COL.CENT CAUTION H BLK L COL.MAX H BLK R COL.MIN • Use an isolation transformer when performing any service V.
Page 6
ELECTRICAL ADJUSTMENTS 2-5: BRIGHT CENT Receive the monoscope pattern. (RF Input) Set the screen mode to FULL. Using the remote control, set the brightness and contrast to normal position. Activate the adjustment mode display of Fig. 1-1 and press the channel button (29) on the remote control to select "BRI.
Page 7
ELECTRICAL ADJUSTMENTS 2-10: HORIZONTAL SIZE 2-14: TRAPEZIUM Receive the monoscope pattern. Receive the crosshatch signal from the Pattern Generator. Using the remote control, set the brightness and Using the remote control, set the brightness and contrast contrast to normal position. to normal position.
Page 8
ELECTRICAL ADJUSTMENTS 2-17: OSD POSITION 2-18: Confirmation of Fixed Value (Step No.) Receive the monoscope pattern from the Pattern Please check if the fixed values of each of the adjustment Generator. item is set correctly referring below. Using the remote control, set the brightness and ANALOG DIGITAL VIDEO1, VIDEO2...
ELECTRICAL ADJUSTMENTS 3-3: STATIC CONVERGENCE 3. PURITY AND CONVERGENCE ADJUSTMENTS NOTE Adjust after performing adjustments in section 3-2. NOTE Receive the crosshatch pattern from the color bar Turn the unit on and let it warm up for at least 30 generator.
Page 17
CRT / SVM SCHEMATIC DIAGRAM (CRT PCB) CRT BLOCK L801 150uH 0607 FROM DEFLECTION R802 CP801B 2.7K 1/4W R803 FROM DEFLECTION B2013H02-5P RED OUT RED OUT 180V Q804 C802 S801 Q801 100.6 15K 2W KTC4217 R812 KTC3199_Y 123.0 0.001 TP022 D810 C811 R817...
Page 18
POWER & GROUND SCHEMATIC DIAGRAM FROM/TO SDRAM (DIGITAL PCB) FROM/TO FLASH/GPIO FROM/TO VIF/SIF DTV_ASIC IC DTV_ASIC IC IC2401 ZR39740HGCF-B0 (1/6 POWER) IC2401 ZR39740HGCF-B0 (2/6 GND) FROM/TO AV IN/OUT VDD Bypass Cap Place cap near pin C2424 3V3_D ADAC_VDD MVDD VDD Bulk Bypass cap 0.1 B Place 1 cap per side of ZR740 ADAC_VSS...
Need help?
Do you have a question about the DTV2794 and is the answer not in the manual?