Taco Comfort Solutions 007-F5-7IFC Instruction Sheet

Cartridge circulators

Advertisement

SUPERSEDES: May 1, 2010
Plant I.D. 001-934

ApplICATION:

1. Maximum operating pressure is 125 psi (862 kPa).
2. Maximum water temperature not to exceed nameplate rating.
3. Cast iron circulators are to be used for closed loop systems. Bronze or stainless steel circulators are to be used for
open loop, fresh water, or potable water systems.
4. Taco Cartridge circulator pumps are for indoor use only – employer uniquement a l´interieur.

INsTAllATION:

1. Mounting position – Circulator must be mounted with the motor in a horizontal position. It may be mounted
vertically with the motor up, provided that the system pressure is at least 20 psi (138 kPa).
CAUTION:
DO NOT Use flAT rUbber gAskeTs. ONly Use O-rINg gAskeTs
prOvIDeD Or leAks mAy resUlT. WArrANTy WIll be vOID.
2. Rotating body – Body has an arrow on the front that indicates direction of flow. To rotate body, remove the four body
bolts, rotate body and replace bolts. Make sure that the junction box is NOT located underneath the circulator. (The
junction box must NOT be located in the 6 o'clock position, as viewed from the motor end.)
3. Electrical connections – Observe all applicable codes when connecting to power supply. The motor is impedance
protected, and does not require overload protection. Either colored wire from the capacitor box can be attached to
either colored wire from the power supply. There is no "hot" or "common" wire leading from the capacitor box. Typical
installation would be to attach the white wire to the white (common) power supply wire and either the yellow or blue
wire to the black (hot) power supply wire. The pump cannot run backwards.
WArNINg: Do not use in swimming pool or spa areas; pump has not been investigated for this
application.
WArNINg: In the event the retaining screws have been pulled out of the housing, DO NOT replace
them. Use of any other screw may short out the stator windings, creating a risk of elec-
trical shock.
CAUTION: When installing electrical connections, do not apply mechanical loads to the capacitor
box; otherwise, retaining screws may be pulled out of the housing, making circulator
unusable.
CAUTION: Installations at higher elevations over 5000 feet must have higher fill pressure of 20 psi
minimum to prevent pump cavitation and flashing. premature failure may result. Adjust
expansion tank pressure to equal fill pressure. A larger size expansion tank may be required.
4. Fill system with tap water – The system must be filled before operating the circulator. The bearings are water lubri-
cated and should not be allowed to operate dry. Filling the system will result in immediate lubrication of the bearings.
It is always good practice to flush a new system of foreign matter before starting the circulator.
CAUTION: Never run the circulator dry or permanent damage will result.
5. Circulator operation – Operate the circulator for 5 minutes immediately after filling system to purge remaining air from
the bearing chamber. This is especially important when installing the circulator during the off-season.
CAUTION: 1. The addition of petroleum based fluids or certain chemical additives to systems
utilizing TACO equipment voids the warranty.
2. Use supply wires suitable for 90°C – ATTeNTION: employer des fils d´alimentation
adequats pour 90°C.
Instruction Sheet
"00" Cartridge Circulators
102-054
EFFECTIVE: July 1, 2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Comfort Solutions 007-F5-7IFC and is the answer not in the manual?

Questions and answers

Summary of Contents for Taco Comfort Solutions 007-F5-7IFC

  • Page 1 3. Cast iron circulators are to be used for closed loop systems. Bronze or stainless steel circulators are to be used for open loop, fresh water, or potable water systems. 4. Taco Cartridge circulator pumps are for indoor use only – employer uniquement a l´interieur. INsTAllATION: 1.
  • Page 2 THe AbOve WArrANTIes Are IN lIeU Of culator or circulator part which is proven defec- is suitable for use with a Taco product or part, or All OTHer WArrANTIes, eXpress Or tive under normal use within three (3) years from...

This manual is also suitable for:

Comfort solutions 007-f5-7-ifcComfort solutions 005-zf2-6Comfort solutions 003-zb4-1Comfort solutions 0014-vdtf1Comfort solutions 0011-zf4-2Comfort solutions 0011-vvf4 ... Show all

Table of Contents