High Level Sensors
When the tank level is not at full, the float is in the down
position, normal condition, the contact is closed: no
alarm (F
. 5, illustration a).
IG
As the tank level rises and reaches the level sensor, the
float moves to the up position and opens the contacts
(F
. 5, illustration b).
IG
Low Level Sensors
When the tank is not empty, the float is in the up
position, normal condition, the contact is closed: no
alarm (F
. 5, illustration c).
IG
As the tank level falls and reaches the level sensor, the
float moves to the down position and opens the
contacts (F
. 5, illustration d).
IG
NOTE: For clarity, F
. 5 does not show the splash
IG
guard.