Kvaser USBcan Pro 2xHS v2 User’s Guide Copyright 2023 GMGA MEASURING - Hanoi, Vietnam https://gmga.vn/ Printed Thurday 20th July, 2023 We believe that the information contained herein was accurate in all respects at the time of printing. GMGA MEASURING cannot, however, assume any responsibility for errors or omissions in this text. Also note that the information in this document is subject to change without notice and should not be construed as a commitment by GMGA MEASURING.
Page 2
Kvaser USBcan Pro 2xHS v2 User’s Guide 2 (24) (This page is intentionally left blank.) GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
About this manual This manual is intended for Kvaser USBcan Pro 2xHS v2 users. This document contains a description of the hardware’s properties and general instructions for connecting the device to a computer. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
Kvaser USBcan Pro 2xHS v2 see Table 8 on Page 16. Device Product Number Firmware Driver (Windows/Linux) Kvaser USBcan Pro 2xHS v2 73-30130-00752-9 v3.24 v5.36 (kcany/mhydra) Table 1: Product number together with software versions needed to support all functionality present in this guide. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
USBcan Pro 2xHS v2 makes it possible to react much quicker to CAN bus events (for example to speed up file transfer protocols or to simulate missing hardware). For more information, see the Kvaser t Programming Language guide that can be downloaded at www.kvaser.com/download. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
Predefined t Program Related Functions scriptLoad Predefined Logger Related Functions filterDropMessage loggerStatus loggerStart loggerStop Other Predefined Functions timeGetDate Table 2: Functionality in the t language (v3.10) that is not supported by Kvaser USBcan Pro 2xHS v2. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
Visual Basic. Kvaser CAN and LIN hardware is built around the same common software API. Applications developed using one device type will run without modification on other device types. The latest versions of documentation, software and drivers can be downloaded for free at www.kvaser.com/download. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
Figure 2: A standard USB type “A” connector. Connect the device to your computer using any high quality USB 2.0 certified cable. The ∼ maximum total USB cable length is 5 m ( 16 ft). GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
The Kvaser USBcan Pro 2xHS v2 has one power LED and one traffic LED for each CAN channel as shown in Figure 4 on Page 11. Their functions are described in Section 4.1, Definitions of LED states and colors, on Page 12. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
Kvaser USBcan Pro 2xHS v2. If the firmware version shown is all zeros, there are communication problems. If the LEDs are not flashing or do not light up at all, check the power supply. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
“Power green->Power yellow->Traffic 1 yellow->Traffic 1 red- >Traffic 2 yellow->Traffic 2 red->. . . ” As an example, "Slow Waver (Green/Yellow)" means that the LED is slowly blinking by alternating between green and yellow. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
Page 13
This should not normally happen. If it does, please contact Kvaser support. This indicates low power supply, such as using an unpowered USB hub. The red Traffic LED indicating overrun will stay on until the device goes bus off. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
50 x 170 x 20 mm for body incl. strain relief Weight 170 g ◦ ◦ −40 C to +85 Operating temperature ◦ ◦ −40 Storage temperature C to +85 Relative humidity 0 % to 85 % (non-condensing.) Table 6: Technical Specifications. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
Sometimes a single terminator is sufficient. For production, proper termination is essential. If you see error frames on the bus, you should check the termination. To save yourself a lot of trouble, always terminate the CAN bus properly. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
Device Tree of “Kvaser Device Guide” in your computer’s control panel. If all your hardware is placed in one Kvaser MagiSync Group, then you are ready to go. When connected correctly, all units are synchronized achieving a high precision virtual clock accurate to the microsecond. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
Page 17
Kvaser USBcan Pro 2xHS v2 User’s Guide 17 (24) Figure 6: An example setup where all devices are synchronized via MagiSync. Figure 7: Not all devices are synchronized via MagiSync in this setup. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
CANtegrity function included in the Kvaser USBcan Pro 2xHS v2 (00752-9). More information about Kvaser CANtegrity can be found on https://www.kvaser.com/kvaser- cantegrity/. Figure 8: Using information from Kvaser CANtegrity, the time between two edges can be measured. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
19 (24) Disposal and Recycling Information When this product reaches its end of life, please dispose of it according to your local environmental laws and guidelines. For information about Kvaser’s recycling programs, visit: https://www.kvaser.com/en/kvaser/recycling-policy.html GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
KVASER AB HEREBY EXPRESSLY DISCLAIMS ANY LIABILITY OVER AND ABOVE THE REFUNDING OF THE PRICE PAID FOR THIS DEVICE, SINCE KVASER AB DOES NOT HAVE ANY INFLUENCE ON THE IMPLEMENTATIONS OF THE HIGHER-LEVEL SYSTEM, WHICH MAY BE DEFECTIVE. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
EN 55024 (2010) EN 55032 (2012) EN 61000-6-3 (2007 + A1:2011) EN 50581 (2012) Signed for and on behalf of: 2019-12-05 Molndal Place of issue Date of issue Claes Haglund, Supply Chain and Quality director GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
(2) this device must accept any interference received, including interference that may cause undesired operation. RESPONSIBLE PARTY (IN USA) NAME: Kvaser Inc. 23881 Via Fabricante, Suite 503 Mission Viejo, CA 92691 Internet contact: support@kvaser.com GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
MagiSync is a trademark of Kvaser AB. DeviceNet is a trademark of Open DeviceNet Vendor Association, Inc. NMEA 2000 is the registered trademark of the National Marine Electronics Association, Inc. For information about Kvaser related CAN patents, see www.kvaser.com/patent. GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
Url protocol updated 2020-01-27 Added sdoc 2020-08-19 Updated supported OS 2021-09-09 CANtegrity support was added, dropped mention of Hi-Speed CAN 2022-02-15 Added chapter about CANtegrity 2022-04-01 Added Android to Technical data table, minor textual changes GMGA MEASURING - Hanoi, Vietnam — https://gmga.vn/...
Need help?
Do you have a question about the Kvaser USBcan Pro2xHS and is the answer not in the manual?
Questions and answers