SVOTON Technology Precautions Please read everything in the manual carefully before using the product described in this manual, and read the following notes carefully in order to ensure that the bar code scanning equipment according to the design indicators of safe use, please carefully keep the instructions, so that the future at any time to check.
SVOTON Technology Revision History Date Version Describe 2018-10-20 Initial version 2018-11-20 Remove invalid content Remove the hand-scanned phone 2018-12-15 barcode, add Han XinCode,modify the manual Chinese word description. 2019-03-15 New series of common feature version manual 2019-08-28 Add some suffix samples;add...
SVOTON Technology Table of Contents Precautions ....................... 2 Revision History ......................3 Foreword ......................... 10 Brief Introduction .................. 10 Chapter Outline ..................10 Chapter 1 Connection and Basic Settings ............... 11 Introduction ..................11 Unpacking .................... 11 Device Connection ................11 USB Connection ..................
Page 5
SVOTON Technology Good Read Delay ................25 Chapter 4 Data Editing .................... 26 Introduction ..................26 Add Prefix or Suffix ................27 Example ....................28 Add a Suffix to a specific symbology ........... 28 To Add a Carriage Return Suffix to All Symbologies ......29 To Add a Line Break Suffix to All Symbologies ........
SVOTON Technology Foreword Brief Introduction This manual provides bar code scanning equipment Start-up and configuration instructions, as well as maintenance and customer support information. Chapter Outline Chapter 1 Connections and Basic Settings :introduces the method and default settings for bar code scanning devices...
SVOTON Technology Chapter 1 Connection and Basic Settings Introduction The barcode scanner supports three connection methods. Please follow the appropriate connection procedure to connect the barcode scanner. Unpacking To open the product packaging, perform the following steps: • Remove the scanner and its accessories and inspect for damage during shipment.
SVOTON Technology USB Connection The barcode scanner can be connected to the USB port of your computer. Connect the device interface (RJ45 connector) of the USB cable to the device. Connect the host interface (USB interface) of the USB cable to the host.
SVOTON Technology RS232 Connection Connect the device interface (RJ45 connector) of the RS-232 cable to the scanner. Connect the host interface (RS-232 interface) of the RS-232 cable to the host. The barcode scanner is humming. Verify the operation by scanning the...
SVOTON Technology Barcode Reading The barcode scanner has a line of sight/point that projects a red aiming beam that corresponds to the horizontal field of view of the barcode scanner. The line of sight/point should be at the center of the barcode, but it can be positioned in any direction to facilitate reading.
SVOTON Technology Chapter 2 Interface Type Introduction This chapter introduces the USB and RS232 interface types and lists their related configurations. RS232 Connect RS232 interface, you need to scan the "RS232" barcode, the serial port related configuration is: 115200 baud rate, 8 data bits, no parity, 1 stop bit, add carriage return and line feed by default.
SVOTON Technology RS232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate. The host terminal must be set for the same baud rate as =115200. the scanner. Default (8310030.) (8310031.) (8310032.) 1200 (8310033.)
SVOTON Technology (8310037.) 38400 (8310038.) 57,600 (8310039.) *115,200 RS232 Word Length: Data Bits, Stop Bits, and Parity Data Bits You can choose to transfer 7,8-bit data bits, and you must set the terminal to the same data bit as the barcode scanner to communicate properly.
SVOTON Technology USB PC Keyboard Scan one of the following code to program the scanner for USB PC Keyboard .Scanning these code also adds a CR and LF. (881001124.) USB Keyboard (PC) USB Serial Scan the following code to program the scanner to emulate a regular RS232- based COM Port.
SVOTON Technology Chapter 3 Input/Output Settings Introduction This chapter mainly introduces the configuration of the beep and LED of the barcode scanner when it is powered on, decoded, and triggered by the button. Startup Beeper The scanner can be programmed to beep when it’s started up. Default = Startup Beeper On.
SVOTON Technology Good Read and Error Read Indicators Good Read Beeper The beeper may be programmed On or Off in response to a good read. Default = Good Read Beeper On (8410010.) Good Read Beeper Off (8410011.) * Good Read Beeper On...
SVOTON Technology Good Read Beeper Frequency The beeper frequency codes modify the frequency of the beep the scanner emits on a good read. Default = Medium. (8410061600.) Low (1600 Hz) (8410062400.) * Medium (2400 Hz) (8410064200.) High (4200 Hz) Good Read Beeper Duration The beeper duration codes modify the length of the beep the scanner emits on a good read.
SVOTON Technology (8410073250. Medium (3250 Hz) (8410074200.) High (4200 Hz) Good Read LED The LED indicator can be programmed On or Off in response to a good read. Default = On. (8410081.) * Good Read LED On (8410080.) Good Read LED Off...
SVOTON Technology Good Read Delay This sets the minimum amount of time before the scanner can read another barcode. Default = * Short Delay (750 ms) (8510060.) No Delay (851006750.) * Short Delay (750 ms) (8510061000.) Medium Delay (1,000 ms) (8510061500.)
SVOTON Technology Chapter 4 Data Editing Introduction This chapter describes how to add prefixes and suffixes. • Default prefix = None. Default suffix = None. • A prefix or suffix may be added or cleared from one symbology or all symbologies.
SVOTON Technology Add Prefix or Suffix Step 1. Scan the Add Prefix or Add Suffix symbol Step 2. Determine the 2 digit Hex value from the Symbology Chart for the symbology to which you want to apply the prefix or suffix. For example, for Code 11, Code ID is “h”...
SVOTON Technology Example Add a Suffix to a specific symbology To send a CR (carriage return)Suffix for code 128. only: Step 1. Scan Add Suffix. Step 2. Determine the 2 digit hex value from the Symbology Charts code 128. Step 3. Scan 6, 3 from the...
SVOTON Technology To Add a Carriage Return Suffix to All Symbologies Scan the following barcode if you wish to add a carriage return suffix to all symbologies at once. This action first clears all current suffixes, then programs a carriage return suffix for all symbologies.
SVOTON Technology Keyboard Operation Different operations can be performed on the keyboard through configuration during decoding output, such as automatic saving after decoding output. Step 1: determine the hexadecimal value corresponding to the keyboard operation to be performed from the...
SVOTON Technology Clear Prefixes or Suffixes You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. If you have been entering prefixes and suffixes for single sym- bologies, you can use Clear One Prefix (Suffix) to delete a specific char- acter from a symbology.
SVOTON Technology Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Default = Enable. (8870010.) * Enable (8870011.) Disable Intermessage Delay An intermessage delay of up to 5000 milliseconds (in 5ms increments) may be placed between each scan transmission.
SVOTON Technology Chapter 5 Symbologies Introduction Each type of barcode has its own unique properties. The barcode scanner can be adjusted to accommodate these property changes through the configuration code in this chapter. The fewer the barcode types, the faster the barcode scanner can read.
SVOTON Technology All Symbologies If you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On barcode. If on the other hand, you want to decode only a particular symbology, scan All Symbologies Off followed by the On barcode for that particular symbology.
SVOTON Technology Codabar (900000.) Default All Codabar Settings On/Off (9000031.) * On (9000030.) Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the barcode. You may either transmit, or not transmit Start/Stop characters.Default = Don’t Transmit. (9000061.) Transmit (9000060.)
Page 37
SVOTON Technology (9000010.) * No Check Character (9000011.) Validate but Don’t Transmit (9000012.) Validate and Transmit www.svoton.com...
SVOTON Technology Concatenation Codabar supports symbol concatenation. When you enable concatena- tion, the scanner looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two mes- sages are concatenated into one with the “D” characters omitted.
SVOTON Technology Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60. (900005.) Minimum Message Length (900004.) Maximum Message Length www.svoton.com...
SVOTON Technology Code 39 < Default All Code 39 Settings > (901000.) Default All Code 39 Settings Code 39 On/Off (9010011.) * On (9010010.) Start/ Stop Characters Start/Stop characters identify the leading and trailing ends of the barcode. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit.
SVOTON Technology Check Character No Check Character indicates that the scanner reads and transmits bar- code data with or without a check character. When Check Character is set to Validate, but Don’t Transmit, the unit only reads Code 39 barcodes printed with a check character, but will not transmit the check character with the scanned data.
SVOTON Technology Code 39 Append This function allows the scanner to append the data from several Code 39 barcodes together before transmitting them to the host computer. When the scanner encounters a Code 39 barcode with the append trigger char- acter(s), it buffers Code 39 barcodes until it reads a Code 39 barcode that does not have the append trigger.
SVOTON Technology Code 32 Pharmaceutical (PARAF) Code 32 Pharmaceutical is a form of the Code 39 symbology used by Ital- ian pharmacies. This symbology is also known as PARAF. When you configure code32, you need to turn on code39 before you configure it.
SVOTON Technology FULL ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar- code symbol will be interpreted as a single character. For example:$V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #.
SVOTON Technology Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings > (902000.) Default All Interleaved 2 of 5 Settings On/Off (9020021.) * On (9020020.) Check Digit No Check Digit indicates that the scanner reads and transmits barcode data with or without a check digit.
Page 46
SVOTON Technology (9020011.) Validate, but Don’t Transmit (9020012.) Validate and Transmit www.svoton.com...
SVOTON Technology Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. (902004.) Minimum Message Length (902003.) Maximum Message Length www.svoton.com...
SVOTON Technology NEC 2 of 5 < Default All NEC 2 of 5 Settings > (903000.) Default All NEC 2 of 5 Settings On/Off (9030011.) * On (9030010.) Check Digit No Check Digit indicates that the scanner reads and transmits barcode data with or without a check digit.
Page 49
SVOTON Technology (9030021.) Validate, but Don’t Transmit (9030022.) Validate and Transmit www.svoton.com...
SVOTON Technology Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. (903004.) Minimum Message Length (903003.) Maximum Message Length www.svoton.com...
SVOTON Technology Code 93 < Default All Code 93 Settings > (904000.) Default All Code 93 Settings On/Off (9040021.) * On (9040020.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 0-80.
SVOTON Technology Straight 2 of 5 Industrial (three-bar start/stop) <Default All Straight 2 of 5 Industrial Settings> (905000.) Default All Straight 2 of 5 Industrial (three-bar start/stop)Settings On/Off (9050011.) (9050010.) * Off Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information.
SVOTON Technology Matrix 2 of 5 <Default All Matrix 2 of 5 Settings> (907000.) Default All Matrix 2 of 5 Settings On/Off (9070011.) (9070010.) * Off Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information.
SVOTON Technology Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. (908004.) Minimum Message Length (908003.) Maximum Message Length www.svoton.com...
SVOTON Technology Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. (909003.) Minimum Message Length (909002.) Maximum Message Length www.svoton.com...
SVOTON Technology GS1-128 <Default All GS1-128 Settings> (910000.) Default All GS1-128 Settings On/Off (9100011.) * On (9100010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-80.
SVOTON Technology Telepen <Default All Telepen Settings> (911000.) Default All Telepen Settings On/Off (9110011.) (9110010.) * Off Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-60.
SVOTON Technology UPC-A <Default All UPC-A Settings> (912000.) Default All UPC-A Settings (9120031.) * On (9120030.) Note: When UPC-A Off is scanned, UPC-A barcodes are transmitted as EAN- 13. Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not.
SVOTON Technology Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. (9120051.) * On (9120050.)
SVOTON Technology Addenda Required When Required is scanned, the scanner will only read UPC-A barcodes that have addenda. You must then turn on a 2 or 5 digit addenda. Default = Not Required. (9120061.) Required (9120060.) * Not Required Addenda Separator When this feature is on, there is a space between the data from the barcode and the data from the addenda.
SVOTON Technology UPC-E0 <Default All UPC-E Settings> (914000.) Default All UPC-E0 Settings On/Off Most U.P.C. barcodes lead with the 0 number system. To read these codes, use the *UPC-E0 On selection. If you need to read codes that lead with the 1 number system, use UPC-E1.
SVOTON Technology Expand UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off. (9140021.) (9140020.) * Off Addenda Required When Required is scanned, the scanner will only read UPC-E barcodes that have addenda. Default = Not Required.
SVOTON Technology (9140040.) Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = On. (9140051.) (9140050.) www.svoton.com...
SVOTON Technology Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. To prevent transmission, scan Off. Default = On.
SVOTON Technology UPC-E1 Most U.P.C. barcodes lead with the 0 number system. For these codes, use UPC-E0. If you need to read codes that lead with the 1 number system, use the UPC-E1 On selection. Default = Off. (9140091.) UPC-E1 On (9140090.)
SVOTON Technology Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. (9150021.) * On (9150020.) Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data.
SVOTON Technology Addenda Required When Required is scanned, the scanner will only read EAN/JAN-13 barcodes that have addenda. Default = Not Required. (9150051.) Required (9150050.) * Not Required Addenda Separator When this feature is On, there is a space between the data from the barcode and the data from the addenda.
SVOTON Technology EAN/JAN-8 <Default All EAN/JAN-8 Settings> (916000.) Default All EAN/JAN-8 Settings On/Off (9160011.) * On (9160010.) Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
SVOTON Technology (9160031.) 2 Digit Addenda On (9160030.) * 2 Digit Addenda Off (9160041.) 5 Digit Addenda On (9160040.) * 5 Digit Addenda Off Addenda Required When Required is scanned, the scanner will only read EAN/JAN-8 barcodes that have addenda. Default = Not Required.
Page 73
SVOTON Technology When this feature is On, there is a space between the data from the barcode and the data from the addenda. When turned Off, there is no space. Default = On. (9160061.) * On (9160060.) www.svoton.com...
SVOTON Technology Check Characte MSI barcodes use different types of check characters. You can configure the barcode scanner to read the MSI barcode using the check character. Default = Validate MOD 10, but Don’t Transmit When Check Character is set to Validate MOD 10 and Transmit, the...
SVOTON Technology PDF417 < Default All PDF417 Settings > (924000.) Default All PD417 Settings On/Off (9240011.) * On (9240010) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-2750.
SVOTON Technology QR Code < Default All QR Code Settings > (928000.) Default All QR Code Settings On/Off This selection applies to both QR Code and Micro QR Code. (9280011.) * On (9280010.) Message Length Scan the barcodes below to change the message length. Refer to...
SVOTON Technology Data Matrix < Default All Data Matrix Settings > (930000.) Default All Data Matrix Settings On/Off (9300011.) * On (9300010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-3116.
SVOTON Technology Aztec Code < Default All Aztec Code Settings > (931000.) Default All Aztec Code Settings On/Off (9310011.) * On (9310010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-3832.
SVOTON Technology China Post (Hong Kong 2 of 5) <Default All China Post (Hong Kong 2 of 5) Settings> (936000.) Default All China Post (Hong Kong 2 of 5)Settings On/Off (9360011.) (9360010.) * Off Message Length Scan the barcodes below to change the message length. Refer to...
SVOTON Technology Korea Post <Default All Korea Post Settings> (937000.) Default All Korea Post Settings On/Off (9370011.) (9370010.) * Off Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 2-80.
SVOTON Technology Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data. Default = Don’t Transmit. (9370041.) (9370040.) * Off Han Xin Code <Default All Han Xin Code Settings>...
SVOTON Technology Micropdf <defalt all micropdf settings> (925000.) On/Off (9250011.) (9250010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366.
SVOTON Technology <defalt all composites settings> (926000.) On/Off (9260011.) (9260010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-2435. Minimum Default = 1, Maximum Default = 2435.
SVOTON Technology Chapter 6 Utilities Show Software Revision Scan the barcode below to output the current software revision, unit serial number, and other product information. (809005.) Show Revision www.svoton.com...
SVOTON Technology Chapter 7 Common Problems And Solutions Problem: The barcode scanner does not work. possible reason: 1. The barcode scanner is not powered, check the power of the equipment. If you are using an incorrect cable, use the cable that was originally configured.
SVOTON Technology Chapter 8 Maintenance And Customer Service Maintenance Stains and dust on the scanning window can sometimes affect the normal operation of the barcode scanner. When cleaning, use a good quality tissue to wipe gently, or use a soft cloth to clean.
Page 93
SVOTON Technology Possible Symbology Modifiers (m) GS1 DataBar GS1 DataBar Limited GS1 DataBar Expanded GS1-128 2 of 5 China Post (Hong Kong 2 of Interleaved 2 of 5 0, 1, 3 Matrix 2 of 5 NEC 2 of 5 Straight 2 of 5 IATA...
SVOTON Technology Postal Symbologies Possible Symbology Modifiers (m) All Symbologies Australian Post British Post Canadian Post Symbology Possible Modifier (m) China Post InfoMail Intelligent Mail Bar Code Japanese Post KIX (Netherlands) Post Korea Post Planet Code Postal-4i Postnet www.svoton.com...
Page 105
SVOTON Technology (800002.) Save (800000.) Discard Note: If an error occurs while scanning a letter or number (before scanning the "Save" barcode), scan the "Discard" barcode, rescan the correct letter or number, and then scan the "Save" barcode. www.svoton.com...
Page 106
SVOTON Technology ASCII conversion of keyboard operation CTRL+X FUNCTION CTRL+@ CTRL+A Select all CTRL+B Bold CTRL+C Copy CTRL+D Bookmark CTRL+E Center CTRL+F Find CTRL+G CTRL+H History CTRL+I CTRL+J Justify CTRL+K Hyperlink CTRL+L CTRL+M CTRL+N CTRL+O Open CTRL+P Print CTRL+Q Quit...
Need help?
Do you have a question about the MG-1650S and is the answer not in the manual?
Questions and answers