ClareOne Panic Pendant (Keyfob)
Installation Sheet
Part number: CLR-C1-PNC
Description
The ClareOne Panic Pendant (Keyfob) is a lithium battery
operated wireless handheld panic device for the ClareOne
Panel system. When the button is pressed, a wireless signal is
sent to the panel, setting the panel to Panic.
Notes
•
The ClareOne Panel must be monitored for the panel's
panic state to be received at a call station.
•
Non-supervised sensors should be tested once a week,
ensuring proper function.
Important safety instructions
Before you program this sensor, be sure to:
•
Read, keep, and follow all instructions.
•
When there is a low battery, replace with a compatible
lithium ion battery within 7 days.
Setup
Use the ClareOne panel to add the panic pendant.
To add the pedant to the panel:
Add the sensor to the panel. See "Sensor Management."
1.
ClareOne User Guide (DOC ID 1871).
2.
Once added, test the sensor.
Look at the ClareOne panel, and then press the panic
button.
Notice that the panel enters an alarmed state.
© 28MAY20 Clare Controls, LLC.
Note: Testing all sensors to the alarm monitoring station
is strongly advised.
Button function
The pendant has 1 button. Once the pendant is added to the
panel, pressing the button sends a wireless alert to the panel.
This alert sets the panel to Panic. If the ClareOne Panel has a
monitoring service, the alarm monitoring station is notified.
Battery replacement
The ClareOne Panic Pendant requires a CR2032 battery.
When the battery is low, the panel displays a low battery icon
next to the sensor in the devices list. The battery must be
replaced within 7 days of the first low battery notification. If the
battery is not replaced within 7 days, the sensor may not
function properly.
Note: Regular battery maintenance is important, see your
battery manufacturer for recommended battery replacement
frequency.
WARNING:
If an incompatible replacement battery is used, or
the battery is installed incorrectly explosion or damages may
occur.
AVERTISSEMENT: Si une batterie de remplacement
incompatible est utilisée ou si la batterie est installée de
manière incorrecte, une explosion ou des dommages peuvent
survenir.
To replace the battery:
Note:
Verify that the panel is not armed before changing the
battery.
1.
Hold the panic pendant firmly in one hand.
2.
Slide both thumbnails in the side indent, and then pull the
sides away from each other.
1 / 3
DOC ID – 1926 • Rev 03
Need help?