Sensor suite with solar radiation sensor
Table of Contents

Advertisement

Check Sensor Interface Connections and Connect the
Anemometer Cable
The sensor interface is located in the transmitter shelter on the front of the sensor
suite. It contains all the connections for the weather sensors of the sensor suite.
Follow the steps below to check the sensor interface and ensure that all sensors are
connected properly.
Open the Transmitter Shelter
1. Locate the white box with the solar
panel containing the sensor interface
on the front of the sensor suite unit.
The cabled model does not have a solar
panel.
2. Locate the white tab at the bottom
center of the shelter cover.
3. Pull the tab away from the box while
sliding the cover up.
4. Look on the side of the shelter. The box
cover can be easily removed from the
box when the alignment indicator on
the cover is lined up with the alignment
indicator on the box
5. Pull the cover off the box, being
careful not to stress the solar panel
cable when removing the cover.
6. The sensor interface is visible once the cover has been removed.
Note:
See "Sensor Interface" on page 34 for information on locating the components and
points of interest on the sensor interface.
Optional: Disconnect the solar panel
connection wire (wireless versions).
The solar panel on the box cover is
connected to the sensor interface by a
wire. If the cover cannot be set aside
while still connected to the sensor
interface safely, the cable can be
disconnected.
6