Advertisement

Quick Links

Moving Details.
Inhalt
1
1.1
1.2
1.3
1.4
1.4.1
1.4.2
2
2.1
2.2
3
3.1
3.2
3.3
3.5
3.5.1
3.5.2
3.5.3
3.6
4
5
5.1
5.2
5.3
5.3.1
5.3.2
5.3.3
5.3.4
5.3.5
Mounting instruction
UNIQUIN
Mounting profile
2
2
5.4.1
2
5.4.2
2
5.4.3
2
5.4.4
2
5.5
2
6
2
6.1
2
6.1.1
3
6.1.2
3
6.1.3
3
6.2
3
6.2.1
4
6.2.2
4
6.3
4
4
7
4
7.1
4
7.2
5
8
5
6
6
6
6
6
7
8
9
9
EN
WN 059546 45532
2023-08 / 16676
10
10
11
11
12
12
12
13
14
14
15
15
16
17
17
17
17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UNIQUIN and is the answer not in the manual?

Questions and answers

Summary of Contents for DORMA-Glas UNIQUIN

  • Page 1: Table Of Contents

    Mount base profiles vertically Foreseeable misuse 6.1.2 Mount base profiles horizontally Product description 6.1.3 Siliconize sound insulation units Example of a UNIQUIN unit Mount fixed elements Product variants 6.2.1 Mount side panels Parts included 6.2.2 Mount additional unit components (optional) 3.4 Example of a mounted mounting profile...
  • Page 2: About This Manual

    Further labeling Information about the manual Step-by-step graphics This manual describes how to install a UNIQUIN mounting profile as part of a UNIQUIN partition wall system and provides Position numbers for parts maintenance and care information. in diagrams Further unit components and mounting instructions may be required to complete the UNIQUIN partition wall unit’s mounting...
  • Page 3: Foreseeable Misuse

    Product description Example of a UNIQUIN unit WARNING This UNIQUIN unit is an example of a UNIQUIN partition wall Danger to life due to falling glass. unit. Further combinations with other unit components, e.g. with an Falling glass can lead to life-threatening injuries.
  • Page 4: Parts Included

    DORMA-Glas UNIQUIN Mounting profile Product description Parts included Specifications of the mounting profiles The exact delivery quantities and profile lengths vary depending 3.5.1 Glass thickness from 10-13.5 mm on the product variant or the planned combination of the unit components. The glass is not part of the delivery. The profiles can •...
  • Page 5: Glass Clamping Piece

    DORMA-Glas UNIQUIN Mounting profile Storage and transport Glass clamping piece Storage and transport CAUTION Risk of injury due to heavy weight. Lifting heavy components can result in injury. • Lift the heavy components together with several persons or a suitable lifting device.
  • Page 6: Installation Preparation

    DORMA-Glas UNIQUIN Mounting profile Installation preparation Installation preparation 5.3.1 Prepare inside T-joint CAUTION Risk of injury due to sharp edges. Contact with cut edges can lead to cuts. • Wear protective gloves. • Deburr cutting edges. • Blunt the cut edges, e.g. with silicone.
  • Page 7: Prepare Outside T-Joint

    DORMA-Glas UNIQUIN Mounting profile Installation preparation 5.3.2 Prepare outside T-joint E+33,5 Fig. 14 Outside T-joint on the side of the base profile 46 (55) Fig. 12 Inside T-joint, profile cut on site Base profile 1 Base profile 1.1 Base profile 1.2 Base profile 2 Cover profile 1.1 = Linear measure A1...
  • Page 8: Prepare Corner Joint For Outside Corner

    DORMA-Glas UNIQUIN Mounting profile Installation preparation 46 (55) Fig. 18 Example of a mounting with corner joint for outside corner Base profile 1 Base profile 2 Fig. 16 Outside T-joint, profile cut on site Cover profile 1 Base profile 1 Cover profile 2...
  • Page 9: Corner Joint For Inside Corner

    DORMA-Glas UNIQUIN Mounting profile Installation preparation 5.3.4 Corner joint for inside corner • Base profile outside: Miter joint • Cover profile inside: Miter joint 3 ±2 Fig. 20 Corner joint for inside corner Fig. 22 Corner joint for inside corner, profile cut on site...
  • Page 10: Prepare Profiles

    DORMA-Glas UNIQUIN Mounting profile Installation preparation Prepare profiles If the dimensions on site are more than 5 mm over the If the profiles are available in longer or warehouse lengths, the project-related unit drawing’s specifications, then adjust the profiles and seals must be cut to size before mounting.
  • Page 11: Attach Silicon Seals

    DORMA-Glas UNIQUIN Mounting profile Mounting Attach silicon seals CAUTION Requirement Risk of injury due to heavy weight. • The profiles are cut. Lifting heavy components can result in injury. • Lift heavy components together with several people Identify the groove provided for the silicone seal depending on and with suitable lifting device.
  • Page 12: Mount Base Profiles

    DORMA-Glas UNIQUIN Mounting profile Mounting Fix the base profile to all drill holes. NOTE It is recommended that, when following the mounting sequence of the unit components, the fixed elements should be mounted from one side to the other, e.g. beginning on the wall towards a door frame.
  • Page 13: Siliconize Sound Insulation Units

    DORMA-Glas UNIQUIN Mounting profile Mounting Correctly siliconize the joints from the inside of the profile NOTE before mounting the cover profiles. If e.g. an omission of the base profile on the ground is planned for an acoustic element, then: Only prepare the horizontal base profiles on the ground to one side of the omission.
  • Page 14: Mount Fixed Elements

    DORMA-Glas UNIQUIN Mounting profile Mounting Mount fixed elements Requirements • The base profiles are mounted. • The acoustic element is prepared (optional). • The door frame system is prepared (optional). 6.2.1 Mount side panels If necessary, align and mount the door frame positioner on the unit’s alignment according to the door frame unit’s mounting...
  • Page 15: Mount Additional Unit Components (Optional)

    DORMA-Glas UNIQUIN Mounting profile Mounting 10. Maintain the distance between the clamping pieces of approx. 13. Mount a clamping piece in the horizontal base profiles at the 80 mm to the corner (Fig. 35) top and bottom exactly on the joint of the side panels.
  • Page 16: Mount Cover Profiles

    DORMA-Glas UNIQUIN Mounting profile Mounting Mount cover profiles NOTE Requirements • The recess allows the mounting of the cover profile • The unit components are correctly mounted. without tilting with the abutting base profile. • The cover profiles are prepared and cut to length as needed (see •...
  • Page 17: Maintenance And Care

    DORMA-Glas UNIQUIN Mounting profile Maintenance and care Maintenance and care CAUTION Risk of injury due to cut edges Touching cut edges can lead to cuts, e.g. at the corner joint of an acoustic element. • Wear protective gloves. Maintenance instructions The product is largely maintenance-free.
  • Page 18 DORMA-Glas UNIQUIN Mounting profile Mounting WN 059546 45532 2023-08 / 16676...
  • Page 19 DORMA-Glas UNIQUIN Mounting profile Mounting 2023-08 / 16676 WN 059546 45532...
  • Page 20 Moving Details. DORMA-Glas GmbH Max-Planck-Straße 33-45 D - 32107 Bad Salzuflen T +49 5222 924-0 info@dorma-glas.com www.dorma-glas.com DORMA-Glas GmbH DORMA-Glas GmbH...