4) Attach the bottom stainless steel skirts into the pre-tapped supports and seal if required (see assembly instructions). 5) A Stark representative will set up the tank once electrical power and drains are connected. Please call to confirm. STARK Products Co., Inc.
LOBSTER TANK The lobster tank provides an environment that closely simulates the natural ocean waters in which lobsters thrive. As a result, Stark Lobster Tanks keep more pounds of lobsters alive for a longer period than any other closed system available today.
Page 3
– Stark Lobster Tank Operating Instructions BREAK-IN PERIOD: One of the key components of the Stark Filtration System is the biological filter bed. During the initial installation and start-up process, the Activated Sand for the sand filter will be introduced into the system. This will commence the process of building up the level bacteria necessary for a solid biological filter.
Page 4
The filtration system will not work properly if the level of water is below this mark. Pre-mix salt water as follows: Add 1 lb. (16 oz.) of Stark Marine Crystals to 4 gallons of cold water. Mix well, and add slowly to tank.
Page 5
– Stark Lobster Tank Operating Instructions MARK III - PROTEIN SKIMMER WATER LEVEL Located in the window behind the skimmer. The protein skimmer removes the foamy protein lobster waste products found in the water. Through this filtration process, the tank will lose water and the water level will drop.
Page 6
– Stark Lobster Tank Operating Instructions SKIMMER WARNING! Do Not Use the valve marked "Service Only" to adjust the Skimmer. This valve is to be used is to used by a service technician only. STARK Products Co., Inc. 2/21/2020 SLS-80 BULLET Tel.
Page 7
WARRANTY: Stark provides a one-year warranty on all mechanical parts of the tank. During the term of the warranty, Stark will replace mechanical parts deemed to be defective from the manufacturing process at no cost. STARK Products Co., Inc.
If lobsters have been in cooler for more than 2 days, DO NOT put them into the tank. USE ONLY the proper size pre-cut exact fit Stark Filter Pads, Marine Salt Crystals and Carbon.
Page 9
Stark) would we recommend a water change. If necessary, use salt water (1 lb salt to 4 gallons of water) to fill the tank. Stark ships a 1 lb jar of chlorAm-x, which is used for start-up to keep the ammonia level low until the biological system can handle the bio-load.
Mix in a bucket: 1 lb of Stark Marine Salt with 4 gallons of water, then pour into the tank. NOTE: Never add undissolved salt or a large amount of fresh water directly into the tank.
3) What do I do if lobsters start dying? Call Stark. One of our experienced technicians will work with you over the phone, or via video conferencing, to help resolve the issue as expeditiously as possible. If is determined that the issue cannot be resolved remotely, the Stark technician will make a service visit to resolve accordingly.
– Stark Lobster Tank Operating Instructions TROUBLESHOOTING GUIDE Symptom Possible Cause and Action More than 4 buckets of The skimmer may be set too high. Water level in water need to be added daily. the skimmer window must be at MARK III.
A421 Series Standard Electronic Temperature Controls Installation Instructions Part No. 24-7664-3019, Rev. D Issued March 2016 A421ABC-x, A421AEC-x, A421GBF-x, A421GEF-x Refer to the QuickLIT website for the most up-to-date version of this document. Applications Dimensions IMPORTANT: Use this A421 Series Electronic Temperature Control only as an operating control.
Page 19
Parts Included Mounting Each A421 Control includes a Johnson Controls/ Observe the following guidelines when locating and PENN® A99 Series temperature sensor. See A99 mounting an A421 control: Series Temperature Sensors, Wiring, and Technical • Ensure that the mounting surface can support the Specifications for more information about A99 sensors.
Page 20
3. Position the control mounting slots over the screw Wiring heads, and then carefully tighten the mounting WARNING: Risk of Electric Shock. screws to secure the control to the surface. Disconnect or isolate all power supplies 4. When mounting the control on an uneven surface, before making electrical connections.
Page 21
Table 1: Maximum Recommended Sensor Cable IMPORTANT: When connecting an A99 sensor Lengths and Wire Sizes with a shielded cable to an A421 Control, connect Wire the cable shield drain lead to the COM (common) Maximum Sensor Cable Length Gauge terminal on the sensor and binary input terminal Feet (Meters) block (TB3).
Page 22
Figure 4: Wiring the A421 Series Controls Using the Same Power Source to Power the Control Operation and Power the Controlled Equipment Table 2: A421 Control Wiring Terminals and Wire Size Information (Part 1 of 2) Terminal Label Description, Function, and Requirements Recommended Block Wire Sizes...
Table 2: A421 Control Wiring Terminals and Wire Size Information (Part 2 of 2) Terminal Label Description, Function, and Requirements Recommended Block Wire Sizes Detects a switch closure between the BIN and COM terminals and enables 22 AWG (0.34 mm the selected temperature setback (tSb) value.
Page 24
Three-Button Touchpad Anti-Short Cycle Delay (ASd): Select the minimum time that the output relay remains off (de-energized) The touchpad has three buttons for setup and before the next on-cycle can start. The ASd interval adjustment of the A421 control (Figure 5). See Menu overrides any load demand (On) and does not allow Navigation Guidelines on page 9 for more information the output relay to go on until the selected ASd interval...
Page 25
Temperature Units (Un): Select the desired • the temperature setback feature is enabled and the temperature scale for your application. Select either the control uses the effective On and OFF setback Fahrenheit (°F) or Celsius (°C) temperature scale. values (On + tSb and OFF + tSb) to control the relay.
Page 26
A421 Control Parameter Setup Menus The A421 temperature controls provide a Basic and an Advanced setup menu that allow you to scroll through the parameter setup codes, view and edit parameter values, and set up your control for your application requirement.
Page 27
To exit the Basic menu and go directly into the Viewing and Changing Values in the Advanced Advanced menu, simultaneously press and , and Menu hold them for 5 seconds. To access the Advanced menu and view and change the parameter values, follow these steps: Advanced Menu The Advanced menu allows you to change the...
Page 28
• The control band (differential) is defined by the On 4. Disconnect power to the control and reposition the and OFF values, and the control band between On jumper to one pin (Figure 10). Reconnect power. and OFF remains fixed (not adjustable). •...
5. Press and simultaneously to return to the Troubleshooting Main screen. Fault Codes A421 Series controls display fault codes on the LCD as described in Table 5. Figure 11: Adjusting Temperature in the Restricted Menu Table 5: Fault Codes Defined Fault Code Definition System Status...
g. If the sensor’s measured resistance value is Press MENU until On appears. Press MENU substantially different from the expected value again to display the On value. for that temperature, check the sensor wiring. If g. Press or to change the On temperature sensor wiring is correct, replace the sensor.
Page 31
Table 6: A421 Series Standard Electronic Temperature Controls Selection Chart (Part 2 of 2) Product Type Description A421AEC-02C Line-Voltage Type 4X Electronic Temperature Control: Type 4X (NEMA), IP66 watertight enclosure for surface-mount applications. Rated for 120/240 VAC. Includes an A99BB-200C temperature sensor with 6.6 ft (2.0 m) cable.
Table 8: Accessories (Part 2 of 2) PLT344-1R Two End Clamps for DIN rail sections A99-CLP-1 Surface Mounting Clip for A99B and A99C Series Temperature Sensors SHL10-603R Sun Shield for A99B and A99C Series Temperature Sensors BOX10A-603R PVC Enclosure for A99B and A99C Series Temperature Sensors WEL11A-601R Copper and brass immersion well for applying sensor in fluid applications TE-6300W-102...
Page 33
Table 11: UL Conformity Declaration Information (Part 2 of 2) External Pollution Situation All Models: A421 [ ] B: Pollution Degree 3 All Models: A421 [ ] E: Pollution Degree 4 Internal Pollution Situation Pollution Degree 2 Heat and Fire Resistance Category Rated Impulse Voltage 4000 V Ball Pressure Temperature...
Page 34
European Single Point of Contact: NA/SA Single Point of Contact: APAC Single Point of Contact: JOHNSON CONTROLS JOHNSON CONTROLS JOHNSON CONTROLS WESTENDHOF 3 507 E MICHIGAN ST C/O CONTROLS PRODUCT 45143 ESSEN MILWAUKEE WI 53202 MANAGEMENT GERMANY NO. 22 BLOCK D NEW DISTRICT WUXI JIANGSU PROVINCE 214142 CHINA Building Efficiency...