SAFETY INFORMATION Before the installation and use of the appliance, carefully read the supplied instructions. The manufacturer is not responsible for any injuries or damages that are the result of incorrect installation or usage. Always keep the instructions in a safe and accessible location for future reference.
CAUTION: The cooking process has to be supervised. A short • term cooking process has to be supervised continuously. WARNING: Danger of fire: Do not store items on the cooking • surfaces. Metallic objects such as knives, forks, spoons and lids should •...
appliance and the upper drawer, is sufficient for must have a contact opening width of minimum air circulation. 3 mm. • The bottom of the appliance can get hot. Make GAS CONNECTION sure to install a non-combustible separation panel under the appliance to prevent access to •...
Page 5
CARE AND CLEANING WARNING! Risk of damage to the appliance. WARNING! Do not remove the buttons, knobs or gaskets from the control panel. Water may get inside • Do not keep hot cookware on the control panel. the appliance and cause damage. •...
PRODUCT DESCRIPTION COOKING SURFACE LAYOUT Rapid burner Semi-rapid burner Auxiliary burner Control knobs CONTROL KNOB Symbol Description Symbol Description minimum gas supply no gas supply / off position ignition position / maximum gas supply DAILY USE BURNER OVERVIEW WARNING! Refer to Safety chapters. A.
B. Burner crown CAUTION! In the absence of C. Ignition candle electricity you can ignite the burner D. Thermocouple without electrical device; in this case approach the burner with a flame, turn IGNITION OF THE BURNER the control knob counter-clockwise to maximum gas supply position and Always light the burner before you put push it down.
• When the liquid starts to boil, turn down the flame to barely simmer the liquid. Diameter of cook- Burner ware (mm) DIAMETERS OF COOKWARE Use cookware with diameters Semi-rapid 120 - 220 applicable to the size of burners. Auxiliary 80 - 180 Diameter of cook- Burner...
TROUBLESHOOTING WARNING! Refer to Safety chapters. WHAT TO DO IF... Problem Possible cause Remedy There is no spark when you try The hob is not connected to an Check if the hob is correctly to activate the spark generator. electrical supply or it is con- connected to the electrical nected incorrectly.
LABELS SUPPLIED WITH THE ACCESSORIES Stick the adhesive labels as indicated below: MOD. MOD. MOD. TYPE PROD.NO. IP20 PROD.NO. PROD.NO. SER.NO. 0049 SER.NO SER.NO 03 IT DATA DATA MADE IN ITALY A. Stick it on Guarantee Card and send this part C.
Page 11
gas supply. You can find this plate in the package supplied with the appliance. If the supply gas pressure is changeable or different from the necessary pressure, you must fit an applicable pressure adjuster on the gas supply pipe. ADJUSTMENT OF MINIMUM LEVEL To adjust the minimum level of the burners: 1.
CONNECTION CABLE 6. Reassemble the gasketthe magnet holder and the knob. To replace the connection cable use only the special cable or its equivalent. The cable type is: H03V2V2-FT90. Make sure that the cable section is applicable to the voltage and the working temperature. The yellow / green earth wire must be approximately 2 cm longer than the brown (or black) phase wire.
min. 100 mm min. 650 mm min. 55 mm 30 mm 550 mm min 6 mm min 12 mm min 5 mm (max 150 mm) 60 mm Kitchen unit with oven The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit.
GAS BURNERS FOR LPG G30/G31 30/30 MBAR NORMAL POWER MINIMUM POW- NOMINAL GAS FLOW BURNER INJECTOR MARK ER kW Rapid 0,75 Semi-rapid 0,45 Auxiliary 0,33 ENVIRONMENTAL CONCERNS with the symbol with the household waste. Recycle materials with the symbol . Put the Return the product to your local recycling facility or packaging in relevant containers to recycle it.