28mm in-line magnetic filter

Advertisement

4. INSTALLATION METHOD
1. Cut and remove the section of the pipe according to the product installation length;
2. Install the valves onto the pipework, hand tighten only at first, then tighten securely the valve to the pipe;
3. Install the filter housing and tighten it;
4. Adjust the Angle and secure the filter;
5. Make sure the valves are open, allow the system to fill, open, and vent the filter through the air vent valve,
close when complete.
1
2
5. MAINTENANCE AND SERVICING
Note: Prior to carrying out any maintenance work, isolate the electrical supply to the boiler allowing
the water to cool down to a safe working temperature.
1. Close both the isolation valves;
2. Open the drain valve, place a bucket or similar receptacle below ready to collect the debris. Take out the
magnetic bar and store in a safe place;
3. Open the inlet valve to flush out the debris, once all the debris has been removed introduce a suitable
chemical inhibitor into the system, we recommend Salus LX1 inhibitor, refit the magnetic bar;
4. Open the inlet and outlet valve, vent the filter through the air vent valve close when complete.
Check for any leaks;
5. Complete any relevant documentation.
IE: Dates and inhibitor used.
3
4
Note: It is recommended that the magnetic filter is installed and maintained by a competant and
qualified person. Any queries arising from either installation or servicing, contact SALUS Controls at
techsupport@salus-tech.com
1
2
Maximum working pressure: 6bar
Flow rate: < 50 l/min
Please note:
1. The magnetic filter contains powerful magnets, please keep away from all electronic devices, bank cards
and other magnetic devices;
2. The Magnetic Filter contains powerful magnets and should always be used with caution especially for
devices such as pacemakers;
3. The Magnetic Filter is a pressurized device, pressure must be released prior to maintenance;
4. The Magnetic Filter device could be very hot during operation. Please be careful!
* In order to maintain grounding continuity in accordance with the current IEE regulations, appropriate grounding cables should be
installed on the pipe where necessary to bypass the product.
Instruction manual of magnetic filter
* Please read the product manual carefully before installation and use.
3
4
Maximum operating temperature: 95 °C
Direction of flow: follow the arrow