HT3000 high-speed version is a new series of HMI launched by HNC. in 2019, based on the original HMI system to improve the speed of the HT3000 series, and on the basis of HT3000 to optimize the definition of HD version HT3000-H series.
10.1" 1024x600 4G + 512M + SD Global 4G/3G/2G 3. HMI Bundled software HT3000 needs to be used with HTCloud Designer editing software. Please download from HNC official website: http://www.hncelectric.com/. It is also recommended to download HNC Cloud APP “IoTBus”...
1. HMI connection settings HT3000 communicates with the PLC through the RS232 serial port, RS485 serial port or Ethernet port. During the hardware wiring process, the HT3000-10 communicates with the PLC through the RS232 serial port and connects to the static Ethernet network.
Step 2: Open [Project configuration] in the project browser, and click [Project properties] to enter the project property configuration interface. Step 3: Select the device model in the [Layout Info] field, which is consistent with the current device model. In this example, HT3000-10 is taken as an example. Select HT3000-10 and click [OK]. 7 / 28...
b. Download project Project Step 1: Enter the device manager, you can choose to use the local manager or cloud manager; Step 2: Click [Download project] to enter the project download confirmation interface; Step 3: In the confirmation download interface, you can choose whether to reserve the history and alarm records, whether to reserve the formula and whether to package the font download.
Could manager Step 1: enter device manager, click [ cloud manager ], optional log in with mobile phone or email. PS: device administrator and machine owner can manage current device through cloud manager, common user don’t have administrative authority. Step 2: user input correct account and password, click [ sign in ] enter device manager, choice[ manage ].
Step 3: click [ upload ], wait for the pop-up prompt " upload successful!", click [OK], running the project of device in PC. Firmware update Step 1: click [Firmware update],choice firm package, click [open], The latest firmware update package can be get from HNC Step 2: enter offline update confirm interface, click [update] Step 3:waiting for update to complete, pop-up prompt "...
Check the device version Click[Get version], can to view the current version information of software and hardware of device. Upload the history record Click [ upload the history record],enter the upload interface of history record. ①split history file Step 1: click [start split file], you can split historical files for the recent period of time.
IP / setting to enter the background settings interface a. Project Settings Connect Network Engineering Enter the HT3000-10 background settings interface, click [Project], click [Connect Remote],enter the IP of the HMI in the LAN to be connected to for remote access between HMIs Download project Step 1: Create a project, click [Project] in the HTCloud Designer menu bar, expand the tab, and click [Generate U Disk or SD Card run file];...
Page 14
Step 2: Enter the project settings interface, click [Download Project] to enter the project download interface; Step 3: Insert the U disk, select [SD], select the project according to the requirements, click [OK]. and the HT3000-10 device will automatically restart after the successful download.
Network Settings Ethernet connection Enter the HT3000-10 background settings interface, click [Network], enter the Ethernet settings interface, open the [Switch], the network type includes DHCP and Static IP. ① Dynamic IP Connect the network cable, select [DHCP] for the network type, and click [Save], the device will automatically obtain the IP.
Page 16
After the connection is successful,display the green tick " ". After the connection is successful, you can see the gray i "", click the gray i icon can set the IP address, subnet mask, default gateway, DNS. After setting, click [Save] to set WI-FI IP address information. Click the gray i icon and then click "Ignore WI-FI"...
Click the gray i icon and then click [Close] to close the window. Personal hot spot Click [AP] to enter the personal hot spot interface, the HMI built-in network card can also be shared to share WI-FI hot spots for other users.
Network configuration model The new series of HMI has the following 4 different network configuration models (take HT3000-7 as an example). Standard(HT3000-7)...
The routing modes include:close routing / AP point mode / 4G routing mode / client mode / The repeater mode / 4G client mode, the specific use of each routing mode will be described below. Routing configuration The routing modes include:close routing / AP point mode / 4G routing mode / The repeater mode / client mode/ 4G client mode, the default is "Close routing"...
Page 20
AP mode Enter the HMI background settings interface, click [Network], enter the routing configuration interface, click "Settings", click "AP Mode", a prompt "This mode will turn off 4G and WI-FI, are you sure to switch to this mode?", Click "OK" to set to wireless access point mode.
Page 21
Repeater mode Enter the HMI background settings interface, click [Network], enter the routing configuration interface, click "Settings", click "Repeater", a tips shown "This mode will turn off 4G, confirm switching to this mode?" , Click "OK" , set to repeater mode. In "Repeater"...
c. Settings Settings ① Set the terminal name Enter the HMI background settings interface, click [Settings], in the [Settings] interface, you can see the [terminal name], click [Set], enter the new terminal name, click Enter on the keyboard Name. Terminal name: device name, terminal code: device number.
④ Set the network time Enter the HMI background settings interface, click [Settings], open the [Auto time] in the [Settings] interface, and then click the [Auto time set], the current time will automatically correspond to the network time. Enter the HMI background settings interface, click [Settings], turn off the [Auto time] on the [Settings] interface, and then click [Modify] change time, you can manually enter to set the time.
Page 24
③ LAN access Enter the HMI background settings interface, click [Settings], switch to the [Security] interface, and enable LAN access by default. The user can click [Set password], enter the password to be set, click Enter, then enter the password again, and click Enter to save the LAN access password.
Others ① Set the frequency of cloud online detection Enter the HMI background settings interface, click [Settings], switch to the [Others] interface, click Settings on [Cloud On-line Detection], select the cloud online detection frequency which we need. ② Set the current cloud server Enter the HMI background settings interface, click [Settings], switch to [Others] interface, click [Set] on "Now cloud server", select the cloud server address we need, then the current cloud server is displayed as selected server address.
System Information ① Reboot The user enters the HMI background settings interface, click [Information], select [Reboot], then can restart the HMI device; also can restart the device through the device manager, the operation method can refer to "Device Manager-Restart Device" Instructions for use.
Cloud settings Binding device Enter the HMI background settings interface, click [Cloud], open the [Cloud Switch], and pop up the QR code and machine code. Log in to the cloud APP on your mobile phone, enter the [Device] interface, click the button in the upper left corner of the main interface, scan the QR code to add the device.
On the HMI background settings interface, click [Back] to exit the background settings and enter the project running interface. Thanks for choosing HNC Products, If you have any questions about our products or services, please let us know! Website: www.hncelectric.com...
Need help?
Do you have a question about the HT3000 and is the answer not in the manual?
Questions and answers