Advertisement

Quick Links

FLYBOX
®
®
ASI-OAT
Omnia57 ASI-OAT
-
Installation and User Manual,
(Omnia57 family)
Safety Instructions and Warning Booklet
1
Rev. 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Flybox ASI-OAT

  • Page 1 FLYBOX ® ® ASI-OAT Omnia57 ASI-OAT Installation and User Manual, (Omnia57 family) Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 2 Installation and User Manual, Safety Instructions and Warning Booklet This product is not TSO’d and cannot be installed into traditional FAA Part 23 and similarly Type-Certificate Aircraft Document A2019ASI-OAT Revision#1.0, 02/2019 For firmware version 1.0...
  • Page 3 SECTIONS INTRODUCTION IMPORTANT NOTICE AND WARNINGS INDEX OMNIA57 FAMILY SYSTEM OVERVIEW MECHANICAL INSTALLATION ELECTRICAL INSTALLATION INSTRUMENT SETTINGS OPERATING INSTRUCTIONS TECHNICAL SPECIFICATIONS WARRANTY DISCLAIMER...
  • Page 4 Examples of available screens...
  • Page 5 FLYBOX ® Introduction Thank you for purchasing a Flybox® Omnia57 instrument. Our intent in developing the Omnia57 instrument family was to create a light and compact product, powerful and easy to install and use. The Omnia57 instrument family is equipped with a...
  • Page 6 WARNING: Used to indicate a dangerous situation that can cause personal injury or death if the instruction is disregarded. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 7 Therefore, we strongly suggest to double check all of the electronic instruments available on the aircraft and to turn them on to verify they function correctly. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet...
  • Page 8 ONLY to determine the level of the fuel available in the tanks. WARNING: The unit isn’t waterproof. Serious damage could occur if the unit is exposed to water or spray jets. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet...
  • Page 9 Installation and user Manual, Safety Instructions and Warning Booklet, do not install this instrument in his aircraft. NOTE: Flybox Avionics reserves the right to change or improve its products as well as terms, conditions, and notices under which their products are offered without prior notice.
  • Page 10: Table Of Contents

    4.1 - Minimum Settings Before First Use.…..….….…….…… 4.2 - Panel Indicators And Commands…..…….………….…. 4.3 - Setup Menu Navigation……….…….…..…….………… 4.4 - Main Setup Menu… ………………………….………… 4.4.1 - Gauge Submenu……..…………………….…………… Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 11 5.1 - Firmware Upgrade..……………..…..….….…….………. 5.2 - Backup/Restore……………….…..…….………….….…. 5.3 - Use Of The Instrument……….…….…..…….………….. 5.4 - Logger…..………. ………………………….……………. 35 TECHNICAL SPECIFICATIONS…………………………… CLEANING…………………………………………………….. WARRANTY…………………………………………………… 37 TERM OF USE AND DISCLAIMER………………………… 38 Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 12: Section 1 - Omnia57 Family System Overview

    - A high quality knob encoder with push button for easy access to all features. - Backlight auto dimming feature with one optional sensor for all the Omnia57 installed in the panel. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 13: Interconnection Ability

    CAN bus on the same USB pen drive. A single brightness sensor can provide information to all the connected instruments to automatically adjust the backlight intensity. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 14: Easy Software Update

    1.4 EASY SOFTWARE UPDATE The user can download any new firmware, when available, from Flybox website, connect a USB pen drive to the instrument and freely update it with the last features. With one USB connection only, it will be possible to update every instrument installed in the panel.
  • Page 15: Interfaces

    2 separate CAN BUS: they can be used to connect the Omnia57 instruments together, to interface them with other Flybox instruments or with external devices like Engines ECUs or new devices that will be possible developed in the future.
  • Page 16: Section 2 - Mechanical Installation

    Mechanical installation MECHANICAL INSTALLATION 2.1 MECHANICAL DIMENSIONS The Omnia57 ASI-OAT instrument fits in a standard 2 ¼” (57 mm) panel cutout; it's recommended to choose a position that permits optimal display visibility. It's furnished with four M4 screws to install it to the panel, if you use other screws consider that the maximum thread length inside the instrument body is 10mm (see the picture below).
  • Page 17 FLYBOX ® Mechanical installation NOTE: For an installation without interference, consider making a hole of at least 57.5 mm diameter Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 18: Static And Pitot Piping Connection

    On the back of the instrument there are 2 6mm brass fittings that must be connected and tightened to the Static and Pitot lines of the aircraft by rubber tube. Tighten the tubes with a proper clamp. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 19: Section 3 - Electrical Installation

    Molex P/N 43025-0200 (2 pole housing) Molex P/N 43025-2200 (22 pole housing) Molex P/N 43030-0007 (female crimp terminal) The terminals can be crimped with: - Flybox Professional Crimping Tool cod. 603000 - Molex tool P/N 63819-0000 Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev.
  • Page 20: 22 Pole Female Connector Wiring

    Blue Green Ambient light sensor Light PIN 14 + 5V OUT sensor Flybox ambient light sensor code:105800 (sold separately) SPST switch, its use will be implemented in future updates External switch PIN 15 OAT Input WARNING: Voltage peaks on the supply line exceeding the operating limits can damage the device.
  • Page 21: 22 Pole Connector Table

    GND main supply Alarm Out, NPN 300 mA (not protected) Ambient light sensor input External switch Molex P/N 43025-2200 (22 pole housing). View from wire insertion side. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 22: Sensors Electrical Connections

    FLYBOX ® Electrical installation 3.4 SENSORS ELECTRICAL CONNECTIONS 3.4.1 OAT sensor P1K OAT Sensor Flybox code: 601020 (sold separately) To Omnia57 OAT Input Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 23: Can Bus Connection Wiring

    Each end must be terminated with a 120 ohm resistor, Flybox code 105810. Up to 16 Omnia57 can be connected together through CAN 1 bus. Ready-made termination resistors and wiring for connecting several Omnia57 together are available in different lengths: 25cm, 50cm, 100cm.
  • Page 24: Can Bus Connector Tables

    CAN 2 L Internally connected with the Pin 1 CAN 2 L (Upper connector) CAN 2 H Internally connected with the Pin 2 CAN 2 H (Upper connector) Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 25: Section 4 - Instrument Settings

    FLYBOX ® Instrument settings INSTRUMENT SETTINGS 4.1 MINIMUM SETTINGS BEFORE FIRST USE Omnia57 ASI-OAT CAUTION: Before using the in flight for the first time, you must set at least the following parameters (as explained in the instructions on the following pages): ●...
  • Page 26: Panel Indicators And Commands

    M4 screws Knob with pushbutton The knob can be rotated to select the functions and increment or decrement the values while pressing it to confirm. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 27: Setup Menu Navigation

    - The first items on every menu are Exit or Back. “Exit” is used to quit the Setup and go directly to the main screen, “Back” is used to go back to the previous level. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet...
  • Page 28: Main Setup Menu

    Manual or in Automatic mode. Gauges: select to set the ASI and the OAT gauge setup. Go to chapter 4.4.1 for a full description. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 29 Exit: confirm to go directly to the main screen. Restore Defaults: enter to restore defaults. Caution, the restore default operation returns the instrument to the factory settings. It will require double confirmation. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 30 5.2 for a full description. Logger: enable to save a flight session data. Go to chapter 5.4 for a full description. About: enter to see instrument information. About Page Example Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 31: Gauge Submenu

    Exit: confirm to go directly to the main screen. ASI: set the “ASI” parameters. Go to chapter 4.4.2 for a full description. OAT: set the “OAT” parameters. Go to chapter 4.4.3 for a full description. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 32: Asi Submenu

    (km/h), Knots (kt) or Miles per hour (Mph). Filter: set the fluctuation speed of the ASI readings. Default = 10 Min = 1 (faster) Max = 100 (slower) Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 33 To do the calibration, confirm the “Offset” function; a message indicating you are modifying the offset will appear, confirm “YES”. The new Offset is now set. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 34 Vx and Vy: The indications of Vx and Vy are shown on the speed tape. Set the correct values that will be shown or leave it at 0 not to show them. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet...
  • Page 35 Underspeed: select to set the low speed at which the alarm has to be triggered. To disable it set minimum (off). To disable it set minimum (off). Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 36: Oat Submenu

    Unit: set the unit of measure of the Outside Air Temperature in °C or °F. Filter: set the fluctuation speed of the ISA readings. Default = 10 Min = 1 (faster) Max = 100 (slower) Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 37: Backlight Submenu

    "CAN" to read the ambient brightness from the CAN bus if the brightness sensor is connected to another Omnia57 instrument connected in cluster. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 38 Default = 2 s Min = 1 s (faster) Max 30 s (slower) Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 39 Level 15: 4 Level 30: 8 Level 60: 17 Level 100: 35 Defaults values Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 40: Section 5 - Operating Instructions

    ® Operating Instructions OPERATING INSTRUCTIONS 5.1 FIRMWARE UPGRADE The Omnia57 ASI-OAT software can be easily updated with new versions, when available. To check if a new software version is available, see www.flyboxavionics.it under support > software page. Download the new version and after unpacking it, copy it to a USB stick, possibly free from other files.
  • Page 41 Confirm “Yes” to proceed, “No” to exit without writing software. (DEV. NAME) is the name of the instrument being update. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 42 Note: if the USB stick is installed on a device other than the one you are updating, the following messages will appear on the 2 devices: Device being Remote device Update where the USB is connected Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 43: Backup/Restore

    In this case, simply send the backup file saved on the USB stick to the Flybox support service. To backup or restore the parameters it is...
  • Page 44 Select “Restore” and push the knob to load the previously saved parameters into the instrument. Push the knob to reboot, the new parameters are now loaded in the instrument. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 45: Use Of The Instrument

    5.3 USE OF THE INSTRUMENT When switched-ON, the display will immediately show the main screen. Speed tape Indicated Air Outside Air Speed Temperature indicator Vx, Vy marks Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 46: Logger

    To activate the Logger choose “Yes” from the Main Menu>Logger. The icon will turn green when the file is being written and red when the Logger is enabled but the USB stick is not connected. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 1.0...
  • Page 47: Technical Specifications

    ● 1 OAT input for PT1000 sensors ● Open-collector alarm output (max 300mA, active low). This output can also be used to send a tone in the intercom, using the Flybox optional device code 105899. ● Operating temperature range: -20 ~ +70°C.
  • Page 48: Warranty

    Products is not intended to be used. Flybox®, after verification of the complaint and confirmation that the defect is covered by warranty, at its sole discretion, will either replace or repair the Products at no costs for the customer.
  • Page 49: Term Of Use And Disclaimer

    Use of this product is unauthorized in any jurisdiction that does not give effect to all provisions of these terms and conditions, including without limitation this paragraph. Omnia57 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet...
  • Page 50 WARNING: All photos, data, drawings, instruments layouts, technical solutions and data representation you find in this document or watching at FLYBOX® instruments working and/or you can access by means of any other media, including web sites, are sole property of MICROEL s.r.l., cannot be copied or imitate without a written permission of MICROEL s.r.l.
  • Page 51 Flybox® is a registred brand of Microel s.r.l.- Italy www.flyboxavionics.it MICROEL s.r.l. Via Mortara 192-194 27038 Robbio (PV) - ITALY Tel +39-0384-670602 - Fax +39-0384-671830...