6. PROBLEM SOLVING
In case of any serious problem, the user should consult the appropriate technical service for the repair and overhaul of the
machine. This troubleshooting guide is intended to prevent you from going to your technical centre for easy-to-solve solutions.
Cylinder rod does not move
Slow speed of the cylinder shaft when extending or retracting
Wood does not break or breaks extremely slowly
Engine stalls during splitting
Engine stalls at low load conditions
Posible cause
A- Insufficient oil to pump
B- Air in oil
C- Excessive pump inlet vacuum
D- Hydraulic hoses blocked
E- Control valve blocked
F- Low control valve setting
G- Control valve high setting
H- Control valve damaged
I- Internal leakage of the control valve control valve
J- Internal cylinder leakage
K- Cylinder internally damaged
L- Out of adjustment engine control
M- Engine charging during idle mode
Problem
SOLUTION: A, D, E, H, J
SOLUTION: A, B, C, H, I, K, L
SOLUTION: A, B, C, F, I, K
SOLUTION: G, L
SOLUTION: D, E, L, M
Check the oil level in the tank
Check the oil level in the tank
Check that the pump inlet hose is not blocked or kinked.
Flush and clean the hydraulic system of the splitter.
Flush and clean the hydraulic system of the splitter.
Adjust the control valve with a pressure gauge
Adjust the control valve with a pressure gauge
Send the control valve for repair
Send the control valve for repair
Send the control valve for repair
Send the control valve for repair
Adjust the idle control nuts
Use a shorter trunk (20" or less) to allow the engine to accele-
rate before contact.