TP400 & TP600 Spaside
Operation/Programming Guide
®
BALBOA
BP SERIES
TM
By

Advertisement

loading
Need help?

Need help?

Do you have a question about the BALBOA BP Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HydroQuip BALBOA BP Series

  • Page 1 TP400 & TP600 Spaside Operation/Programming Guide ® BALBOA BP SERIES...
  • Page 3 Contents The Main Screen / Navigation Starting Up System Functions / Features Setting Time of Day Setting Mode / Temp Adjusting Filtration Cycles Locking and Unlocking Spaside Spaside Messages 10-13 CAUTION: Do not connect or disconnect any components while the power is on. All connections must be done with the power off as it may cause damage to the system.
  • Page 4 Main Menu Navigation Navigation Navigating the entire menu structure is done with 2 or 3 buttons on the control panel. Some panels have separate WARM (Up) and COOL (Down) buttons, while others have a single Temperature button. In the navigation diagrams Temperature buttons are indicated by a single button icon.
  • Page 5 System Start-Up Preparation and Filling Fill the spa to its correct operating level. Be sure to open all valves and jets in the plumbing system before filling to allow as much air as possible to escape from the plumbing and the control system during the filling process. After turning the power on at the main power panel, the top-side panel display will go through specific sequences.
  • Page 6 System Functions / Features Pumps Press the “Jets 1” button once to turn pump 1 on or off, and to shift between low- and high-speeds if equipped. If left running, the pump will turn off after a time-out period. The pump 1 low-speed will time out after 30 minutes. The high-speed will time out after 15 minutes.
  • Page 7 Temperature Settings Adjusting the Set Temperature When using a panel with Up and Down buttons (Temperature buttons), pressing Up or Down will cause the temperature to flash. Pressing a temperature button again will adjust the set temperature in the direction indicated on the button. When the LCD stops flashing, the spa will heat to the new set temperature when required.
  • Page 8 Mode Settings Setting Modes In order for the spa to heat, a pump needs to circulate water through the heater. The pump that performs this function is known as the “heater pump.” The heater pump can be either a 2-Speed Pump 1 or a circulation pump. READY Mode - If the heater pump is a 2-Speed Pump 1, will circulate water every 1/2 hour, using Pump 1 Low, in order to maintain a constant water temperature, heat as needed, and refresh the temperature display.
  • Page 9 Filter Settings Main Filtration Filter cycles are set using a start time and a duration. Start time is indicated by an “A” (AM) or “P” (PM) in the bottom right corner of the display. Duration has no “A” or “P” indication. Each setting can be adjusted in 15-minute increments. The panel calculates the end time and displays it automatically.
  • Page 10 LOCKING AND UNLOCKING SPASIDE The control can be restricted to prevent unwanted use or temperature adjustments. Locking the panel prevents the controller from being used, but all automatic functions are still active. Locking the Temperature allows Jets and other features to be used, but the Set Temperature and other programmed settings cannot be adjusted.
  • Page 11 Spaside Messages General Messages Priming Mode Each time the spa is powered up, it will enter Priming Mode. The purpose of Priming Mode is to allow the user to run each pump and manually verify that the pumps are primed (air is purged) and water is flowing. This typically requires observing the output of each pump separately, and is generally not possible in normal operation.
  • Page 12 Spaside Messages Heater-Related Messages Heater Flow is Reduced (HFL) – M016 There may not be enough water flow through the heater to carry the heat away from the heating element. Heater start up will begin again after about 1 min. See “Flow Related Checks” below Heater Flow is Reduced (LF)* –...
  • Page 13 Spaside Messages Sensor-Related Messages Sensor Balance is Poor – M015 The temperature sensors MAY be out of sync by 2°F or 3°F. Call for Service. Sensor Balance is Poor* – M026 The temperature sensors ARE out of sync. The Sensor Balance is Poor fault has been established for at least 1 hour. Call for Service.
  • Page 14 Spaside Messages System-Related Messages Memory Failure - Checksum Error* – M022 At Power-Up, the system has failed the Program Checksum Test. This indicates a problem with the firmware (operation program) and requires a service call. Memory Warning - Persistent Memory Reset* – M021 Appears after any system setup change.
  • Page 16 85-0081 Rev.03 11/15...

This manual is also suitable for:

Tp400 spasideTp600 spaside