Do you have a question about the DA 75A 230 V AC and is the answer not in the manual?
Questions and answers
Summary of Contents for Skov DA 75A 230 V AC
Page 1
DA 75A 230 V AC Technical User Guide For other language variants of this document we refer to http://docs.skov.com/1078 your local dealer 2021.01.04 • 603694...
Page 3
Technical User Guide Product and Documentation Changes SKOV A/S reserves the right to change this maual and the product described herein without further notice. In case of doubt, please contact SKOV A/S. Date of change appears from the front and the back page.
Winding of the winch motor ....................8 Trouble Shooting Instructions ................10 Replacement of the circuit board ..................10 Replacement of the gear motor ..................11 Replacement of the switches ................... 11 Emergency operation ....................... 11 Technical Data ......................12 DA 75A 230 V AC...
Cleaning IMPORTANT: Do not expose the winch motor to water or cleaning with a high-pressure cleaner. Likewise the winch motor must be covered when a possible soaking function is active in the house. DA 75A 230 V AC...
) to AUT and check that the motor is able to open, stop and close via the automatic unit. The opening and closing directions are labelled on the wire wheel. Open Close Fixed Phase P Neutra N Earth Figure 2 DA 75A 230 V AC...
Be aware that other objects do not make any obstacle for the wire when placing the winch motors in the house, e.g. pipes, feed pipes, doors, windows, rafters and light fittings. The winch motor must be placed suitable on grounds of manual operation, service and emergency operation. Figure 3: Placing of the winch motor DA 75A 230 V AC...
If the motor is in a position where it is being activated by the limit switch, it is necessary to help the arms of the limit switch contacts ( ) and (S) on to the cam of the gear-wheel. The thermal cut-out ( DA 75A 230 V AC...
Lead in the coupling through the hole at ( ) until it engages with the motor shaft. If the shaft is turned clockwise, the gear motor opens the system. Do not open or close too much as the mechanical installation may be damaged. DA 75A 230 V AC...
Potentiometer position open 90-95 % af max. * It is assumed that the base is plan, i.e. ≤ 1.5 mm difference of height and that the screws of the cover are tightened with min. 200 Ncm. DA 75A 230 V AC...
Need help?
Do you have a question about the DA 75A 230 V AC and is the answer not in the manual?
Questions and answers