Problem
All 4 LED indicators are blinking on the
battery pack after releasing the trigger
(when the battery pack is in use).
2 LED indicators are blinking on
the battery pack after you press the
battery-charge-indicator button on the
battery pack and the current charge
displays (when the battery pack is not in
use).
2 LED indicators are blinking on the
battery pack after releasing the trigger
(when the battery pack is in use).
1 LED indicator is blinking on the battery
pack.
It is difficult to remove the battery pack
from the tool.
Possible Cause
1. The battery pack is over or under the
appropriate temperature range.
1. There is a difference in voltage
between cells in the battery pack.
1. There is a difference in voltage
between cells in the battery pack.
1. The battery pack voltage is low.
1. The battery pack/tool is new or there
is corrosion in the battery terminals
and/or the terminals on the tool.
22
Corrective Action
1. Move the battery pack to a place
where it is dry and the temperature is
between 0°C (32°F) and 40°C (104°F).
1. Place the battery on the charger until
it is fully charged.
1. Place the battery on the charger until
it is fully charged.
1. Place the battery pack on the charger.
1. Clean the terminals on the battery pack
and the tool. Then apply dielectric
grease to the battery terminals; do not
use any other type of lubricant as it can
damage the terminals.