CDF7000
User manual
RM_CDF7000_315.00_EN_01_2022-12-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CDF7000 and is the answer not in the manual?

Questions and answers

Summary of Contents for ATEQ CDF7000

  • Page 1 CDF7000 User manual RM_CDF7000_315.00_EN_01_2022-12-01...
  • Page 2: Table Of Contents

    GOOD PRACTICES AND SAFETY INSTRUCTIONS ............4 1/33 AIR QUALITY REQUIREMENTS .................... 5 Introduction ....................... 6 ATEQ CDF7000, MULTI-RANGE LEAKAGE CALIBRATOR ..........6 FLOW TEST ..........................6 Measurement principle ....................6 Your ATEQ CDF7000 ....................7 FRONT PANEL ........................7 REAR PANEL .........................
  • Page 3 Changing units ......................23 Switching to standard units and settings ............. 23 Measurement filters ..................... 23 Selecting the gas type ....................24 CONFIGURATION MENU ....................25 2/33 IS/SAE units ........................25 Automatic auto-zero ....................26 Exporting data ......................26 CSV separator ....................... 26 Standby...........................
  • Page 4 ATEQ – Measurement Solution, Global Leader. 3/33 ATEQ 15, rue des Dames, Z.I. info@ateq.com Tel. +33 1 30 80 1020 78340 LES CLAYES-SOUS-BOIS ateq.com Fax: +33 1 30 54 1100 FRANCE ATEQ K.K. 3 – 41 ATEQ Building, Ikehata info@ateq.co.jp Tel: +81 566 84 4670 Chiryū, Aichi pref.
  • Page 5: Safety Instructions / Warranty

    ATEQ is ready to give any information about using the device in optimum safety conditions. Please note that ATEQ cannot be held responsible for any accident related to misuse of the measuring instrument or the workstation or to non-compliance of the installation with the safety rules.
  • Page 6: Air Quality Requirements

    When the instrument is used in a vacuum, prevent impurities from getting inside. We strongly recommend that a suitable airtight filter is installed between the tested part and the instrument. ATEQ specifies the following for the air supply to the device. Air characteristics ISO 8573 class 0.1 μm and 0.1 mg/m...
  • Page 7: Introduction

    ATEQ devices. FLOW TEST Measurement principle The ATEQ CDF7000 measures a pressure drop using a differential sensor, at the terminals of a calibrated pneumatic orifice. It can also be used to check a leakage or a calibrated jet. Connexion avec l'appareil à...
  • Page 8: Your Ateq Cdf7000

    Your ATEQ CDF7000 FRONT PANEL 7/33 The user interface is located on the front panel. Touch screen. Removable handle. Cycle button (START/RESET) Quick connect for pressure measurement. Flow rate measurement connections. For more information, refer to the User Interface chapter.
  • Page 9: Rear Panel

    REAR PANEL 8/33 Handle screws. RS232 connector for Printer / Modbus (option) or Profibus (option) Space for internal battery. Cover screws. Part number/Serial number. Capillary exhaust 2–20 cc/min. Capillary exhaust 250–2500 cc/min. Protective stop. Optional capillary exhausts. 10. Main ON/OFF switch. 11.
  • Page 10: Power Supply Connector

    The external power supply of the previous version of the CDF device cannot be used with the CDF7000. NB Do not use any power supply other than the one provided by ATEQ. Charging When the charger is not connected, the LED is off.
  • Page 11: Digital Connections

    DIGITAL CONNECTIONS PC USB connector USB connectors can be used for connecting miscellaneous compatible USB devices. 10/33 The USB connectors are on the rear of the device (see illustration). USB connector to PC USB connector to USB key Do not connect two USB devices at the same time. Do not use a cable longer than 2 m.
  • Page 12: Rs232 Connector

    RS232 connector RS232 - 9-pin male SubD connector For Printer, Modbus (option) or Profibus (option). RS232 for printer, barcode reader, PC connection. 11/33 Pin number Signal Not used. RXD data input. TXD data input. Not used. Ground. Not used. RTS request to send. CTS clear to send.
  • Page 13: Pneumatic Configuration

    PNEUMATIC CONFIGURATION The leakage calibrator can perform a pressure measurement and a leakage measurement. Pressure measurement 12/33 Connect to the pressure circuit of the device under test. Circuit of the device under test Leakage measurement Connect to the measuring circuit of the device under test. The leakage calibrator has two (or three, depending on options) connections for the leakage test outlet: •...
  • Page 14: Leakage Calibration

    Leakage calibration 13/33 Test STANDARD LEAKAGE pressure RM_CDF7000_315.00_EN_01_2022-12-01...
  • Page 15: User Interface

    User interface INTRODUCTION The front user interface has a touch screen and a user button. 14/33 Touch screen. Cycle button (START/RESET) BUTTON Cycle button The cycle button starts and stops the measurement. In Standby mode, the button is green. Status Name Function Press the button to start the measurement and display...
  • Page 16: Display

    DISPLAY The device has a home screen that changes, depending on the various processes. HOME screen (Standby mode) 15/33 Range selection. Navigation tool. Status icon/shortcuts. Measurement display area. Navigation tools No. Button Description HOME Returns directly to the home screen. AUTO-ZERO Manual start of an auto-zero phase.
  • Page 17 Takes a screen shot of the live screen SCREEN CAPTURE (in ATEQ mode). EXPORT Shortcut to export settings. Indicates that the ATEQ settings are UNLOCKING unlocked. Indication that the USB connection is active / Shortcut to port configuration. Indication of battery level / Shortcut to BATTERY GAUGE battery information.
  • Page 18: Home Screen (In Measurement Mode)

    HOME screen (in Measurement mode) The measurement screen displays the current measurement. The device measures continuously and displays the measurements from the various sensors Bar chart display 17/33 1. Type of measurement display 2. Gas used 3. Flow rate measurement 4.
  • Page 19 Curve display The curve display gives the measurement shown as a bar chart, but the measured points are also displayed as a curve. 18/33 The curve display can be enlarged to full screen by clicking the magnifying glass icon The measurement curve of another sensor can be displayed. Go to the selection menu using the ( ) button, then select the sensor to be displayed.
  • Page 20: Start-Up

    Start-up POWERING UP 19/33 1. Make sure that all the necessary connections are made. Electrical: e.g., power supply, inputs/outputs, etc. Pneumatic: including air line supply pressure. 2. Power up the device. After powering up the device, the Home (Standby mode) screen appears. It displays the 2 cc/min range by default.
  • Page 21: Starting And Stopping Measurements

    STARTING AND STOPPING MEASUREMENTS Use the START/STOP button on the front panel to START/STOP the measurement. Starting the measurement 1.  Press the Start button ( ) . 20/33 The CDF performs a measurement “infinitely” so long as the measurement phase has not been stopped (by pressing Stop).
  • Page 22: User Settings

    User settings The HOME screen (whichever display mode) gives access to various sections 21/33 for managing the device and measurement settings. SETTINGS MENU Use this menu for the measurement settings (units, measurement filters, etc.). Go to settings using the settings button ( ) and select the required setting.
  • Page 23: Available Settings

    Available settings Name Setting Description Units of the various Specific units for each sensor and UNITS sensors each range. Flow rate unit displayed: 22/33 — IS system: mm3/sec, cm /h, cm /min, >FLOW RATE Flow rate unit /s, ml/h, ml/min, ml/s, l/h, l/min, m3/h. —...
  • Page 24: Changing Units

    Activating the Standard Units function affects all the flow rate ranges of the device (measurement and range indication). Measurement filters With the CDF7000, different filter types can be applied to the flow rate measurement. By default, the Filter function is disabled. Two filter types are available: Standard Filter: the standard filter gives a moving average of the n measurements taken in the indicated time period.
  • Page 25: Selecting The Gas Type

    Simple display with no filter function activated. 24/33 Display with Standard Filter activated. The filtering time (T) is shown. Display with Sample Filter activated This shows: The filtering time (T). The number of measurements (N) corresponding to the filter frequency. Standard deviation.
  • Page 26: Configuration Menu

    CONFIGURATION MENU Use this menu to configure your ATEQ device. 25/33 Name Function Description REGIONAL SETTINGS > LANGUAGE Language Selection of the language displayed on screen > DATE FORMAT > TIME FORMAT > UNIT TYPE > DECIMAL PNEUMATIC Pneumatic Configuration of the device's pneumatic functions.
  • Page 27: Automatic Auto-Zero

    Automatic auto-zero This function is found in the Pneumatic submenu. Automatic auto-zero is for periodic auto-zeroing of the flow rate and test pressure sensor. The frequencies are available on a list. 26/33 By default, this function is inactive. Exporting data This function is found in the Automation submenu.
  • Page 28: Maintenance Menu

    Settings reset Configuration. Restores the factory settings (default settings). SENSOR SETTING For setting the sensors (Only accessible in ATEQ mode). Enables each solenoid valve to be turned on/off VALVE CONTROL Valve activation function independently. Information about the device, program version, built-in...
  • Page 29: Calibration Date

    Calibration date This menu shows the date when the differential sensor was last calibrated. It also gives the date recommended for the next calibration. Users can change this date. 28/33 STATUS ICONS Notification This icon returns users to the notification menu. On this menu, various information or warning messages can appear (calibration date overrun, etc.).
  • Page 30: Alarm Message

    Alarm message The interface shows users internal or handling problems in real time. 29/33 PRESSURE – FULL-SCALE EXCEEDED This message shows that the test pressure level is greater than the sensor's full-scale. This can damage the pressure sensor or the device. The START/RESET button flashes red along with the message.
  • Page 31: Calibration Date Overrun

    Press the date information to change it. ATEQ recommends calibration of your devices every 12 months. ATEQ recommends that this calibration is carried out by ATEQ personnel. If this calibration is not performed periodically, measurement drift may not be detected in time.
  • Page 32: Flow Rate Warning

    FLOW RATE WARNING As the measured flow rate approaches the full-scale upper limit, the bar chart display changes colour to alert users. 31/33 When the buzzer is activated, it will sound faster when approaching the full-scale of the selected range. PRESSURE WARNING When the test pressure approaches the full-scale upper limit, the corresponding icon changes colour to alert users.
  • Page 33: Maintenance And Servicing

    EU. This measure applies not only to your device but also to any other accessory marked with this symbol. Do not dispose of these products with unsorted household waste. For more information, contact ATEQ. RM_CDF7000_315.00_EN_01_2022-12-01...
  • Page 34: Technical Characteristics

    Technical characteristics Characteristics Values 33/33 Overall dimensions: Height x Width x Depth 220 x 175 x 230 mm Overall dimensions (with handle) 260 x 175 x 230 mm Weight Approx. 5 kg Li-ion 24 VDC 4 A battery Power supply External power supply 28 VDC Pneumatic air supply (test pressure measurement) Air supply: <1 MPa...