TNC-20-BDC
Body Temperature
Detection Camera
User Manual
Issue V1.1
Date 2019-11-28

Advertisement

Table of Contents
loading

Summary of Contents for WatchNet TNC-20-BDC

  • Page 1 TNC-20-BDC Body Temperature Detection Camera User Manual Issue V1.1 Date 2019-11-28...
  • Page 2: Precautions

    Precautions Precautions Fully understand this document before using this device, and strictly observe rules in this document when using this device. If you install this device in public places, provide the tip "You have entered the area of electronic surveillance" in an eye-catching place. Failure to correctly use electrical products may cause fire and severe injuries.
  • Page 3 Body temperature detection camera Precautions User Manual  If this device is installed in places with unsteady voltage, ground the device to discharge high energy such as electrical surges in order to prevent the power supply from burning out.  When this device is in use, ensure that no water or any liquid flows into the device.
  • Page 4 Body temperature detection camera Precautions User Manual require frequent cleaning. When you found lens image degradation or excessive accumulation of pollutants, you should clear up the window in a timely manner. Exercise caution when you use this device in severe sandstorm (such as deserts) or corrosive environments (such as offshore).
  • Page 5: Table Of Contents

    Body temperature detection camera Contents User Manual Contents Precautions ........................I Contents ........................IV 1 Product Overview ....................1 1.1 About Product ......................... 1 1.2 Features .......................... 1 1.3 Device Dimensions ......................3 1.4 Cable Connection ......................4 2 Quick Configuration ....................6 2.1 Login and Logout ......................
  • Page 6: Contents

    Body temperature detection camera Contents User Manual 4.7 Noise Reduction ......................35 4.8 Enhance Image ......................36 5 Human Thermometer Setting ................37 5.1 Parameter Configure..................... 37 5.1.1 Schedule Linkage ..................... 44 5.2 Thermal Mapping ......................46 5.3 Bad Point Check ......................47 5.4 Thermal Calibration .....................
  • Page 7 Body temperature detection camera Contents User Manual A Troubleshooting....................88 www.watchnetinc.com...
  • Page 8: Product Overview

    Body temperature detection camera Product Overview User Manual Product Overview 1.1 About Product  The body temperature detection camera is integrated with the thermal imaging and temperature measuring, visible fusion, core image intelligent analysis, etc.  Unique double registration mechanism, visible light and thermal imaging is reflecting the same scene.
  • Page 9 Body temperature detection camera Product Overview User Manual  In the heat setting temperature measuring points in the image or temperature area, temperature detection and display: point temperature measurement, regional temperature measuring, full screen, temperature measurement.  Over-temperature warning, temperature difference alarm and over-temperature alarm.
  • Page 10: Device Dimensions

    Body temperature detection camera Product Overview User Manual 1.3 Device Dimensions 1.4 shows the dimensions of device. Figure 1-1 Dimensions (unit: mm) www.watchnetinc.com...
  • Page 11: Cable Connection

    Body temperature detection camera Product Overview User Manual 1.4 Cable Connection Figure 1-2 the multi-connector combination cable of the thermal imaging integrated network camera. For details about the multi-connector combination cable, please refer to Table 1-1. Figure 1-2 Multi-connector combination cable www.watchnetinc.com...
  • Page 12 Body temperature detection camera Product Overview User Manual Table 1-1 Multi-connector combination cable Core of Cable Functions RS485 RS485 interface connects to the external pan & tilt. ALARM IN2 Connects to the alarm device. ALARM OUT2 ALARM IN1 ALARM OUT1 Audio Input Inputs the audio signal and receives the analog audio signals from the sound pick-up device.
  • Page 13: Quick Configuration

    Body temperature detection camera Quick Configuration User Manual Quick Configuration 2.1 Login and Logout You must use Internet Explorer 8 or a later version to access the web management system; otherwise, some functions may be unavailable. Login system Step 1 Open the Internet Explorer, enter the IP address of camera (default value is 192.168.0.121) in the address box, and press Enter.
  • Page 14: Homepage Layout

    Body temperature detection camera Quick Configuration User Manual logout To logout of system, click in the upper right corner of the homepage, the login page is displayed after you logout of the system. 2.2 Homepage Layout On the homepage, user can view real-time video, playback and configuration. User can set parameter, Video parameter, Video control, PTZ control, PTZ Configure and logout of the system.
  • Page 15 Body temperature detection camera Quick Configuration User Manual Element Description Alarm icon When the device generates an alarm, the alarm icon is displayed. You can click to view the alarm information. When the device accepts an alarm signal, the alarm icon will display within 10s in the web management system.
  • Page 16: Changing The Password

    Body temperature detection camera Quick Configuration User Manual ----End 2.3 Changing the Password Description User can click to change the password for logging in to the system. Procedure Step 1 Click in the upper right corner of the main page. The Change Password dialog box is displayed, as shown in Figure 2-3.
  • Page 17: Browse Video

    Body temperature detection camera Quick Configuration User Manual ----End 2.4 Browse Video User can browse the real-time video in the web management system. Preparation To ensure the real-time video can be played properly, you must perform the following operations when you log in to the web for the first time: Step 1 Open the Internet Explorer.
  • Page 18: Install Plugins

    Body temperature detection camera Quick Configuration User Manual Figure 2-5 Configuring ActiveX control and plug-ins Step 3 Download and install the player control as prompted.  The login page is displayed when the control is loaded. 2.4.1 Install Plugins You will be prompted with a message “click here to use short delay Plugin for Live Video”...
  • Page 19: Setting Local Network Parameters

    Body temperature detection camera Quick Configuration User Manual Procedure Step 1 Click the message, download and install the plugin follow the prompts. Step 2 Reopen the browser after installation. Step 3 On live video page, you can operate these buttons as shown in live video. ...
  • Page 20 Body temperature detection camera Quick Configuration User Manual Figure 2-7 Device information Step 2 Set the parameters according to Table 2-2. Table 2-2 Local network parameters Parameter Description Setting IP Protocol IPv4 is the IP protocol that uses [Setting method] an address length of 32 bits.
  • Page 21 Body temperature detection camera Quick Configuration User Manual Parameter Description Setting Subnet Mask Subnet mask of the network [Setting method] adapter. Enter a value manually. [Default value] 255.255.255.0 Default Gateway This parameter must be set if [Setting method] the client accesses the device Enter a value manually.
  • Page 22: Visible Sensor Configuration

    Body Temperature Detection Camera User Manual Visible Sensor Configuration 3.1 Accessing the Sensor Interface Procedure Step 1 On the web or NVMS interface, move the cursor to the real-time video page and right-click on the page. A shortcut menu is displayed, as shown in Figure 3-1 Figure 3-1 Sensor setting interface Step 2 Choose Sensor Configure and the Sensor Setting dialog box appears.
  • Page 23: Image Adjust

    Body Temperature Detection Camera User Manual Figure 3-2 Mode Step 2 Choose the switch mode from the drop-down list. Step 3 Time mode: Set the Start Time, set the End Time. DN linkage Mode, the day mode is correspond to scheme 1, the night mode is correspond to scheme 2. Step 4 Click Save, the message "Save succeed"...
  • Page 24 Body Temperature Detection Camera User Manual Table 3-1 Parameters of Image Parameter Description Configuration Method Brightness It indicates the total brightness of an image. As [Setting method] the value increases, the image becomes Drag the slider. brighter. [Default value] Sharpness It indicates the border sharpness of an image.
  • Page 25: Scene

    Body Temperature Detection Camera User Manual 3.4 Scene Figure 3-4 shows the scene tab page. Figure 3-4 Scene Table 3-2 describes the parameters on the scene tab page. Table 3-2 Parameters of scene Parameter Description Configuration Method Scene Indoor or outdoor. [Setting method] Select a value from the drop-down list.
  • Page 26: Exposure

    Body Temperature Detection Camera User Manual 3.5 Exposure Figure 3-5 shows the Exposure tab page. Figure 3-5 Exposure Table 3-3 describes the parameters on the Exposure setting tab page. Table 3-3 Parameters of exposure setting Parameter Description Configuration Method Exposure Mode The exposure modes include: [Setting method]...
  • Page 27 Body Temperature Detection Camera User Manual Max Shutter It is valid in mode. You can [Setting Iris Priority select a maximum shutter speed. As the method] value increases, the image becomes Select a value brighter. from the drop- down list. [Default value] 1/25 Max gain...
  • Page 28: Daynight

    Body Temperature Detection Camera User Manual Figure 3-6 WB Table 3-4 describes the parameters on the WB tab page. Table 3-4 Parameters of WB Parameter Description Configuration Method Mode It is used to display the real color of a [Setting monitoring scenario when the color temperature method] changes.
  • Page 29 Body Temperature Detection Camera User Manual Figure 3-7 Day-night Table 3-5 describes the parameters on the Special Function tab page. Table 3-5 Parameters of day night www.watchnetinc.com...
  • Page 30 Body Temperature Detection Camera User Manual Parameter Description Configuration Method It can be set to Auto, Day Mode, Night [Setting method] Day Night Mode and Timing. Mode Select a value from the drop-  Auto mode down list. The image color is adjusted based on the [Default value] day/night mode.
  • Page 31: Noise Reduction

    Body Temperature Detection Camera User Manual 3.8 Noise Reduction Figure 3-8 shows the noise reduction tab page. Figure 3-8 Noise Reduction Table 3-6 describes the parameters on the Special Function tab page. Table 3-6 Parameters of noise reduction Parameter Description Configuration Method 2D NR...
  • Page 32: Enhance Image

    Body Temperature Detection Camera User Manual 3.9 Enhance Image Figure 3-9 shows the enhance image Setting tab page. Figure 3-9 Enhance image Table 3-7 describes the parameters on the enhance image setting tab page. Table 3-7 Parameters of enhance image Parameter Description Configuration...
  • Page 33: Zoom Focus

    Body Temperature Detection Camera User Manual It indicates Back Light Compensation (BLC) [Setting method] automatically brings more detail to darker Drag the slider. areas of an image when bright light shining [Default value] from behind obscures it and provides perfect exposure for an object in front of very strong back light.
  • Page 34 Body Temperature Detection Camera User Manual Figure 3-10 Zoom focus Table 3-8 describes the parameters on the enhance image setting tab page. Table 3-8 Parameters of zoom focus Parameter Description Configuration Method D/N Auto [Setting method] Enable the function, if the light is changed, it Focus Tick will focus automatically.
  • Page 35: Thermal Sensor Configuration

    Body Temperature Detection Camera User Manual Thermal Sensor Configuration 4.1 Accessing the Sensor Interface Operation Procedure Step 1 On the Internet Explorer interface or the client software interface, choose channel 2 select and right-click the surveillance image to the set, as shown in Figure 4-1. Figure 4-1 Sensor configuration Step 2 Choose Sensor.
  • Page 36: Images

    Body Temperature Detection Camera User Manual Figure 4-2 Mode interface Operation Procedure Step 2 Click in the lower left corner of Sensor Setting, and choose Debug Mode. Step 3 Choose switch mode from the drop-down list Step 4 Time mode: Set the Start Time, set the End Time. DN linkage Mode, the day mode is correspond to scheme 1, the night mode is correspond to scheme 2.
  • Page 37: Scene

    Body Temperature Detection Camera User Manual Figure 4-3 Image setting interface Step 2 Click in the lower left corner of Sensor Setting, and choose Debug Mode. Step 3 Drag the slider to adjust parameter of image. Step 4 Click Save, the message "Save succeed" is displayed, the system saves the settings. NOTE ...
  • Page 38: Set Pseudocolor

    Body Temperature Detection Camera User Manual Figure 4-4 Scene setting interface Step 2 Click in the lower left corner of Sensor Setting, and choose scene Step 3 Choose mirror mode from drop-list. Step 4 Click Save, the message "Save succeed" is displayed, the system saves the settings. NOTE ...
  • Page 39 Body Temperature Detection Camera User Manual Figure 4-5 Set pseudocolor setting interface Step 2 Click in the lower left corner of Sensor Setting, and choose set pseudo color Step 3 Choose polarity/LUT mode from drop-list. Step 4 Enable or disable the temperature strip switch Step 5 Click Save, the message "Save succeed"...
  • Page 40: Ffc Control

    Body Temperature Detection Camera User Manual 4.6 FFC Control Figure 4-6 shows the FFC control interface. Figure 4-6 FFC control interface Table 4-1 lists the parameters on the FFC control interface. Table 4-1 Parameters on the FFC control interface Parameter Description Setting The internal of the thermal imaging camera may...
  • Page 41 Body Temperature Detection Camera User Manual Parameter Description Setting mode is selected, the FFC interval (minutes) ranges from 5 to 30 minutes. The temperature change of the camera is based on the temperatures collected by the internal temperature probe. The temperature of the camera sharply changes when the camera is powered on.
  • Page 42: Noise Reduction

    Body Temperature Detection Camera User Manual 4.7 Noise Reduction Figure 4-7 shows the Noise reduction interface. Figure 4-7 Noise reduction interface Table 4-2 lists the Noise reduction parameters. Table 4-2 Parameters on the Noise reduction interface Parameter Description Setting [How to set] Select from the drop-down list box.
  • Page 43: Enhance Image

    Body Temperature Detection Camera User Manual 4.8 Enhance Image Figure 4-8 shows the Enhance image interface. Figure 4-8 Enhance image interface Step 2 Click in the lower left corner of Sensor Setting, and choose enhance image. Step 3 Tick defog, then drag the slider to set. It ranges from 0-100, the default value is 50. Step 4 Click Save, the message "Save succeed"...
  • Page 44: Human Thermometer Setting

    Body Temperature Detection Camera User Manual Human Thermometer Setting 5.1 Parameter Configure Operation Procedure Step 1 Choose Configuration >human thermometer >parameter configure. The parameter configure page is displayed, as shown in Figure 5-1. Figure 5-1 Temperature Parameters interface www.watchnetinc.com...
  • Page 45 Body Temperature Detection Camera User Manual Step 2 Set the parameters according to Table 5-1. Table 5-1 Parameter of face detection Parameter Description Setting Face detection Detect face of human [Setting method] Enable [Default value] www.watchnetinc.com...
  • Page 46 Body Temperature Detection Camera User Manual Display trace Display the information of [Setting method] tracing. Enable the button [Default value] Mode 1 Mode 1: Show detection area Enable, the live video will show [Setting method] area of detection. Enable Confidence Face detection sensitivity, the [Setting method] coefficient...
  • Page 47 Body Temperature Detection Camera User Manual Upload image The snapshot mode is optimal, [Setting method] interval set the interval. Input a number from 1 to [Default value] Snapshot count At optimal mode, set the [Setting method] number of snapshot image Input 1 Yaw degree(0-90) Both eyes appear on the screen,...
  • Page 48 Body Temperature Detection Camera User Manual Figure 5-2 Temperature parameters Table 5-2 Temperature parameters Parameter Description Setting Temperature Unit Celsius and Fahrenheit [Setting method] temperature units are available. Select a value from the drop-down list box. [Default value] Celsius Ambient Type The ambient of camera.
  • Page 49 Body Temperature Detection Camera User Manual Parameter Description Setting Correction Correction coefficient refers to [Setting method] Coefficient the deviation of measured Enter a value manually. object temperature and actual [Default value] temperature. 0.00 For example: 1. The measured object temperature is 30, and actual temperature is 37, so the correction coefficient is 7.
  • Page 50 Body Temperature Detection Camera User Manual Figure 5-3 Face alarm linkage Table 5-3 Temperature parameters Parameter Description Setting Output channel Choose channels to output [Setting method] alarm Tick the channels [Default value] Uncheck Alarm rules Set the maximum temperature [Default value] greater than set value Maximum temperature greater than...
  • Page 51: Schedule Linkage

    Body Temperature Detection Camera User Manual Alarm record Enable, install the SD card, [Setting method] when there is an alarm, the Enable camera will record the current video. SMTP Enable, when there is an alarm, [Setting method] the camera will send mail. Enable FTP upload Enable, when there is an alarm,...
  • Page 52 Body Temperature Detection Camera User Manual Figure 5-4 Schedule Linkage Step 2 Choose threshold alarm, threshold temperature difference alarm, threshold warming and temperature difference warming to set. All of these four settings are the same ways to set. Step 3 Check the output channel.
  • Page 53: Thermal Mapping

    Body Temperature Detection Camera User Manual 5.2 Thermal Mapping Operation Procedure Step 1 Choose Configuration >human thermometer >thermal mapping, as shown in Figure 5-5. Figure 5-5 Thermal mapping interface Po int 1 Point 2 Po in t 1 Poin t 2 Po int 3 Point 3 Step 2...
  • Page 54: Bad Point Check

    Body Temperature Detection Camera User Manual Parameter Description Setting Mapping point You need map three points at [Setting method] two channels. Points are Select from drop list . correspond of each. The three points should cover most areas, and two points are located in the diagonal display of the picture.
  • Page 55 Body Temperature Detection Camera User Manual Figure 5-6 Bad point check interface Bad Point 1 Bad Point 2 Step 2 Click the white point at image, click Apply to recover the bad point, as shown in Figure 8-5 www.watchnetinc.com...
  • Page 56: Thermal Calibration

    Body Temperature Detection Camera User Manual Figure 5-7 Recover bad point Step 3 Click Reset to return the previous settings. Step 4 Click Apply. The message "Apply success" is displayed, the system saves the settings. ----End 5.4 Thermal Calibration Enable the thermal calibration function; you need the special calibration tool to check the temperature, input the target temperature (the special calibration tool’s temperature), emission rate and distance of tool, the software can compute automatically.
  • Page 57 Body Temperature Detection Camera User Manual Operation Procedure Step 1 Choose Configuration >human thermometer >thermal mapping, as shown in Figure 5-8. Figure 5-8 Thermal calibration interface Step 2 Enable the button and display area info. Step 3 Input the target temperature, emission rate and distance. Step 4 Click Apply.
  • Page 58 Body Temperature Detection Camera User Manual NOTE  Emission rate is the thermal calibration device,blackbody’s is 0.98.  Distance depends the actual installation distance.  The version information should be provided to sales technicians if the camera is malfunction. Figure 5-9 Version Information www.watchnetinc.com...
  • Page 59: Intelligent Analysis

    Body Temperature Detection Camera User Manual Intelligent Analysis 6.1 Perimeter Description The perimeter function refers to that an alarm is generated when the targets of specified types (such as person, car, and both person and car) enter the deployment area. Procedure Step 1 Select Configuration >...
  • Page 60 Body Temperature Detection Camera User Manual Figure 6-1 Perimeter Setting Interface Step 2 Set all parameters for perimeter. Table 6-1 describes the specific parameters. Table 6-1 Perimeter Parameter Description Parameter Description Setting Channel Channel 1: visible. Choose one channel to set. Channel 2: thermal.
  • Page 61 Body Temperature Detection Camera User Manual Parameter Description Setting Limit The target size for triggering [How to set] Target Size an effective alarm is set based Click to enable Limit on the actual target size. The Target Size. minimum size is 1000 square [Default configuration] centimeters and the maximum100000 square...
  • Page 62 Body Temperature Detection Camera User Manual Parameter Description Setting Enable the button to enable [How to set] Upload File Transfer Protocol. Click to enable FTP Upload. [Default value] PTZ Type Set PTZ type for dome [How to set] cameras and select Select from the drop-down corresponding PTZ type: list.
  • Page 63 Body Temperature Detection Camera User Manual Figure 6-2 Deployment Area Setting Interface NOTE  A drawn line cannot cross another one, or the line drawing fails.  Any shape with 32 sides at most can be drawn.  The quantity of deployment areas is not limited yet and will be described in future when a limit is applied.
  • Page 64: Single Virtual Fence

    Body Temperature Detection Camera User Manual 6.2 Single Virtual Fence Description A single virtual fence is a line that is set at a concerned position within the monitored field of view and specifies the forbidden travel direction; An alarm is generated when the targets of specified types (such as person or car) cross this line.
  • Page 65 Body Temperature Detection Camera User Manual Table 6-2 Parameters of single Virtual Fence Parameter Description Setting Enable Enable the button to enable the [How to set] alarm. Click Enable to enable. [Default value] Limit Target Type Effective alarms are set based [How to set] on target type, with options of Click to enable Limit...
  • Page 66 Body Temperature Detection Camera User Manual Parameter Description Setting Output Channel If you check to set the Output [How to set] Channel and the device is Click to select an ID. connected to an external alarm indicator, the alarm indicator signals when an alarm is triggered.
  • Page 67: Double Virtual Fences

    Body Temperature Detection Camera User Manual NOTE  A single virtual fence is not within any deployment area, therefore, when an alarm is generated, the trace always exists. Only when the target object moves out of the field of view, the trace disappears. ...
  • Page 68 Body Temperature Detection Camera User Manual Procedure Step 1 Select Configuration > Intelligent Analysis > Double Virtual Fences to access the Double Virtual Fences setting interface, as shown in Figure 6-5. Figure 6-5 Double Virtual Fences Setting Interface Step 2 Set all parameters for the double virtual fences.
  • Page 69 Body Temperature Detection Camera User Manual Parameter Description Setting Limit The target size for triggering an [How to set] Target Size effective alarm is set based on the Click to enable Limit actual target size. The minimum size Target Size. is 1000 square centimeters and the [Default configuration] maximum 100000 square...
  • Page 70 Body Temperature Detection Camera User Manual Parameter Description Setting Enable the button to enable File [How to set] Upload Transfer Protocol. Click to enable FTP. [Default value] PTZ Type Set PTZ type for dome cameras and [How to set] select corresponding PTZ type: Select from the drop- Preset/Scan/Track/Tour.
  • Page 71: Object Left

    Body Temperature Detection Camera User Manual NOTE  The two virtual fences are in sequential order. An alarm is generated only when a target crosses virtual fence 1 and then virtual fence 2 within the set maximum passing time.  The double virtual fences are not within any deployment area, therefore, when an alarm is generated, the trace always exists.
  • Page 72 Body Temperature Detection Camera User Manual Figure 6-6 Object Left Setting Interface Step 2 Set all parameters for object left. Step 3 Set a deployment area. Move the cursor to the drawing interface and click to generate a point, move the cursor to draw a line, and then click to generate another point.
  • Page 73: Object Removed

    Body Temperature Detection Camera User Manual 6.5 Object Removed Description The object removed function refers to that an alarm is generated when the removing time of an object within the deployment area meets the set shortest removing time. Procedure Step 1 Select Configuration >...
  • Page 74 Body Temperature Detection Camera User Manual Table 1-1 Description of Parameters for Object Removed Parameter Description Setting Enable Enable the button to enable the alarm. [How to set] Click Enable to enable. [Default value] Minimum The target size for triggering an [How to set] (Maximum) Size(cm effective alarm is set based on the...
  • Page 75 Body Temperature Detection Camera User Manual Parameter Description Setting SMTP Enable the button to enable SMTP [How to set] sever. Click to enable SMTP. [Default value] FTP Upload Enable the button to enable File [How to set] Transfer Protocol. Click to enable FTP Upload.
  • Page 76 Body Temperature Detection Camera User Manual ----End www.watchnetinc.com...
  • Page 77: Alarm Setting

    Body Temperature Detection Camera User Manual Alarm Setting 7.1 Alarm Output Procedure Step 1 Select Configuration > alarm > alarm output to access the alarm output setting interface, as shown in Figure 7-1. Figure 7-1 Alarm output interface Step 2 Set alarm output of channel, name, enable valid signal and alarm time choose alarm output mode.
  • Page 78: Disk Alarm

    Body Temperature Detection Camera User Manual 7.2 Disk Alarm Procedure Step 1 Select Configuration > alarm > disk alarm to access the disk alarm setting interface, as shown in Figure 7-2. Figure 7-2 Disk alarm interface Step 2 Enable the disk full alarm. Set alarm interval , the value is from 10 to 86400 s. Step 3 Tick the channel to push alarm message.
  • Page 79: I/O Alarm Linkage

    Body Temperature Detection Camera User Manual Figure 7-3 Network alarm interface Step 2 Choose network card ID and enable exceptional alarm to set alarm interval. Tick output channel. Step 3 Enable the alarm record. Step 4 Click apply to save the settings, click refresh will return last settings. 7.4 I/O Alarm Linkage Procedure Step 1...
  • Page 80: Motion Alarm

    Body Temperature Detection Camera User Manual Figure 7-4 I/O alarm linkage interface Step 2 Choose alarm input and trigger mode, set name, enable other linkages such as alarm input, PTZ linkage, alarm record, SMTP and FTP upload. Step 3 Set alarm schedule, choose the duration of linkage. Step 4 Click apply to save the settings, click refresh will return last settings.
  • Page 81: Push Message

    Body Temperature Detection Camera User Manual Figure 7-5 Motion alarm interface Step 2 Choose channel and enable the motion alarm, set alarm interval and sensitivity, enable other linkages such as alarm record, SMTP and FTP upload. Step 3 Set motion alarm schedule, Step 4 Click apply to save the settings, click refresh will return last settings.
  • Page 82 Body Temperature Detection Camera User Manual Figure 7-6 Push message interface Step 2 Enable the push message, you will receive the message when the alarm happened. Step 3 Click apply to save the settings, click refresh will return last settings. www.watchnetinc.com...
  • Page 83: Other Web Configurations

    Body Temperature Detection Camera User Manual Other Web Configurations 8.1 Device Information You can view the information about device, as shown in Figure 8-1. Figure 8-1 Device information interface 8.2 Stream 8.2.1 Base Stream Step 1 Choose configuration >stream >base stream, as shown in Figure 8-2. www.watchnetinc.com...
  • Page 84: Svc Stream

    Body Temperature Detection Camera User Manual Figure 8-2 Base stream interface Step 2 Choose channel, stream ID, video encode type, video encode level, audio encode type, resolution, frame rate, frame interval, bit rate type and bit rate from all drop list.
  • Page 85: Roi

    Body Temperature Detection Camera User Manual Figure 8-3 SVC stream interface Step 2 Choose SVC stream ID, elementary stream ID and P frame rate from drop list. Step 3 Click Apply. The message "Apply success" is displayed, the system saves the settings.
  • Page 86: Snapshot

    Body Temperature Detection Camera User Manual Figure 8-4 ROI interface Step 2 Click Apply. The message "Apply success" is displayed, the system saves the settings. 8.2.4 Snapshot Step 1 Choose configuration >stream >snapshot, as shown in Figure 8-5. Figure 8-5 Snapshot interface Step 2 Choose snapshot resolution and snapshot quality from drop list.
  • Page 87: Device

    Body Temperature Detection Camera User Manual 8.3 Device You can set local network, device port, data and time, camera, OSD, microphone, CVBS, system, voice denoise and software licenses, as shown in Figure 8-6. Figure 8-6 Device interface 8.4 External Device Choose configuration >external device, enable PTZ, set parameters as shown in Figure 8-7.
  • Page 88 Body Temperature Detection Camera User Manual Figure 8-7 External device interface www.watchnetinc.com...
  • Page 89: Device Record

    Body Temperature Detection Camera User Manual 8.5 Device Record Choose configuration > device record, enable schedule record, set post record, record audio, record rule(cycle store or save days) and stream name. At this interface, you can also view or modify the information of record directory. Figure 8-8 Device record interface 8.6 Privacy Masking Choose configuration >...
  • Page 90: Network Service

    Body Temperature Detection Camera User Manual Figure 8-9 Privacy masking interface 8.7 Network Service Choose configuration > network service. You can set 802.1x, DDNS, PPPoE, Port mapping, SMTP, IP filter, CGI alarm service center, SNMP and QOS 8.8 Privacy Manager Add user account, manage the users’...
  • Page 91: Protocol

    Body Temperature Detection Camera User Manual Figure 8-10 Privacy manager interface 8.9 Protocol Choose configuration > protocol. You can set protocol information, security, CMS configuration and multicast parameter. www.watchnetinc.com...
  • Page 92: Device Log

    Body Temperature Detection Camera User Manual Figure 8-11 Protocol interface 8.10 Device Log Choose configuration > device log. You can view operation log and alarm log, or collect all log information, as shown in Figure 8-12. Figure 8-12 Device log interface www.watchnetinc.com...
  • Page 93: Maintenance

    Body Temperature Detection Camera User Manual 8.11 Maintenance Choose configuration > maintenance. You can restart, update, reserve IP setting and restore to factory default, as shown in Figure 8-13. Figure 8-13 Maintenance interface 8.12 Local Config Choose configuration > local config. You can choose the snapshot picture format, change the save path of snapshot and local record, as shown in Figure 8-14.
  • Page 94 Body Temperature Detection Camera User Manual Figure 8-14 Local config interface www.watchnetinc.com...
  • Page 95 Body Temperature Detection Camera A Troubleshooting User Manual Troubleshooting Common Trouble Possible Cause Solution Unable to access Network is not Connect the network cable of the camera to the the web connected. PC to check whether the network cable is in good contact.
  • Page 96 Body Temperature Detection Camera A Troubleshooting User Manual Common Trouble Possible Cause Solution The upgrade package Perform the correct upgrade package again. is incorrect. Canada 351 Ferrier Street Unit 5 171 Cooper Ave. Suite 110 PO Box No 126312 Office Suite Markham, Ontario L3R 5Z2 Tonawanda, NY 14150 USA 703, Oxford Towers Business...