1.4 ADDITIONAL CONTROLS

• REMOVING THE FRONT GRILLE

Additional controls are available after removing the front grille and
option cover of control box.
To remove the front grille, pull out the bottom of front grille and
then lift up.
To replace the front grille, place the tabs over the top of the unit
and push the bottom of front grille until the clips snap into place.
• ADDITIONAL CONTROLS
The additional controls are located behind the option cover of control box. The standard settings will be in the OFF position.
The authorized servicer has to check switches and ensure the switches are in the desired position.
REMOTE
ON
OFF
LOCAL
LOCAL
LOCAL
LOCAL
LOCAL
LOCAL
LOCAL
LOCAL
LOCAL
Remote/Local
LOCAL
LOCAL
LOCAL
Energy Saver
1
1
1
Temperature Limit 1
Temperature Limit 2
Temperature Limit 3
PTAC/PTHP
UNIT TYPE

• TEMPERATURE LIMITING

Temperature Limiting can save money by limiting the lowest temperature for cooling and the highest temperature for heating.
The temperature limiting is controlled by switches #3 - #5.
This temperature limiting is not available with the Remote Wall Thermostat.
#3
#4
Temperature
Temperature
Limit #1
Limit #2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
#6
OFF
OFF
ON
ON
Copyright ©2012 LG Electronics. Inc. All right reserved.
Only for training and service purposes
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
1
1
1
1
1
2
2
2
2
2
2
3
3
3
3
3
3
4
4
4
4
4
4
5
5
5
5
5
5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
2
2
3
3
3
4
4
4
5
5
5
#5
Temperature
Lowest Temp.
Limit #3
OFF
54° F (12.2° C)
OFF
56° F (13.3° C)
OFF
58° F (14.4° C)
OFF
60° F (15.5° C)
ON
62° F (16.6° C)
ON
64° F (17.7° C)
ON
66° F (18.9° C)
ON
68° F (20.0° C)
OFF
OFF
6
7
Cooling Operation
Highest Temp.
86° F (30.0° C)
86° F (30.0° C)
86° F (30.0° C)
86° F (30.0° C)
86° F (30.0° C)
86° F (30.0° C)
86° F (30.0° C)
86° F (30.0° C)
#7
OFF
Cooling+Electric Heater+Heat Pump
ON
Cooling+Electric Heater
OFF
Heat Pump Only
ON
Cooling Only
- 9 -
Heating Operation
Lowest Temp.
Highest Temp.
54° F (12.2° C)
86° F (30.0° C)
84° F (28.9° C)
54° F (12.2° C)
82° F (27.8° C)
54° F (12.2° C)
80° F (26.7° C)
54° F (12.2° C)
78° F (25.5° C)
54° F (12.2° C)
54° F (12.2° C)
76° F (24.4° C)
74° F (23.3° C)
54° F (12.2° C)
72° F (22.2° C)
54° F (12.2° C)
Unit Type