LG WM3600HVA-DLE3600V-WDP6V Owner's Manual page 198

Table of Contents

Advertisement

Available languages

Available languages

24 INSTALLATION
Four-Wire Power Cord
• A 4-wire connection is required for
all mobile and manufactured home
installations, as well as all new
construction after January 1, 1996.
• A UL-listed strain relief is required.
• Use a 30-amp, 240-volt, 4-wire,
UL-listed power cord with #10 AWG-
minimum copper conductor and closed
loop or forked terminals with upturned
ends.
1
Remove the terminal block access cover on the
upper back of the dryer.
2
Install a UL-listed strain relief into the power
cord through-hole.
3
Thread a 30-amp, 240-volt, 4-wire, UL-listed
power cord with #10 AWG-minimum copper
conductor through the strain relief.
4
Transfer the dryer's ground wire from behind the
green ground screw to the center screw of the
terminal block.
5
Attach the two hot leads of the power cord to the
outer terminal block screws.
6
Attach the white neutral wire to the center screw
of the terminal block.
7
Attach the power cord ground wire to the green
ground screw.
Terminal Block
UL-Listed Strain Relief
UL-Listed 4-Wire Power
Cord
8
Tighten all screws securely.
9
Reinstall the terminal block access cover.
Hot (Black)
Ground Screw
Power Cord Ground
Wire
Neutral (White)
Hot (Red)
White Wire moved from
Ground Screw

Advertisement

Chapters

Table of Contents
loading

Table of Contents