SINGLE AND DOUBLE PROPELLER - SYNCHRONOUS MOTOR
BT QSY 140
BT QSY 185
BT QSY 250
BT QSY 300
*EN - INSTALLATION AND USER'S MANUAL
REV 001B
*Other languages available by scanning the QR code on the
back of this manual or on the label on the product.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BT QSY Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Quick BT QSY Series

  • Page 1 BT QSY Series REV 001B SINGLE AND DOUBLE PROPELLER - SYNCHRONOUS MOTOR BT QSY 140 BT QSY 185 BT QSY 250 BT QSY 300 *Other languages available by scanning the QR code on the *EN - INSTALLATION AND USER'S MANUAL...
  • Page 3 6 - Maintenance 6.0 - Single/double propeller maintenance 7 - Product disposal 7.0 - Product disposal 8 - Spare parts 8.0 - BT QSY 140/185 8.1 - BT QSY 250/300 9 - Dimensions QUICK BTQSYSERIES INSTALLATION AND USER’S MANUAL - REV001B...
  • Page 5: Information About The Product

    1 - Information about the product BT QSY Series READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USING THE PRODUCT. IF IN DOUBT, CONTACT YOUR QUICK ® DEALER. QUICK RESERVES THE RIGHT TO MODIFY THE TECHNICAL CHARACTERISTICS OF THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT ®...
  • Page 6: Important Notes

    • TCD EX cable 3.0 - Important notes BEFORE USING THE PRODUCT, PLEASE READ THIS USER’S MANUAL CAREFULLY. IF IN DOUBT, PLEASE CONSULT YOUR QUICK® DEALER. This manual features Warning and/or Caution symbols that are important for safety. Please follow the instructions provided.
  • Page 7: Installation Requirements

    The installation of such a unit is an operation that requires experience as well as technical skills. It is recommended that the installation be carried out by competent personnel and that the manufacturer or naval architects be consulted to fully assess the scope of the work. QUICK BTQSYSeries INSTALLATION AND USER’S MANUAL - REV001B...
  • Page 8 • For a proper use of the thruster, we recommend a length equal to 1.5 to 4 times the tunnel diameter. To limit losing charge, a ratio of up to 6 times the diameter can be tolerated. QUICK BTQSYSeries INSTALLATION AND USER’S MANUAL - REV001B...
  • Page 9 • If the tunnel is near the waterline, it is advisable to fit a grating at the end of the tube. The grating must have as large a vertical mesh as possible to avoid contrasting the propeller thrust. The vertical mesh prevents the entry of most of the floating objects. QUICK BTQSYSeries INSTALLATION AND USER’S MANUAL - REV001B...
  • Page 10 Any resin residues and any other hindrance to correct contact must be removed with sandpaper. BTQ SY Ø140/185/250/300 • Insert two O-rings into the special seats inside the flange. QUICK BTQSYSeries INSTALLATION AND USER’S MANUAL - REV001B...
  • Page 11 D. Insert anode E on nut D and lock it with screw F smeared with threadlocker (loctite type). WARNING: on conclusion of assembly, make sure that the propeller is exactly positioned at the central point of the tunnel. QUICK BTQSYSeries INSTALLATION AND USER’S MANUAL - REV001B...
  • Page 12 Electrical connection BT QSY 250 and BT QSY 300 BT QSY 140 and BT QSY 185 AMC EX** AMC QSY ADP** AMC EX** NOT USED AMC QSY ADP** ADAPTER NOT USED **Not supplied QUICK BTQSYSeries INSTALLATION AND USER’S MANUAL - REV001B...
  • Page 13 BT QSY 140 and BT QSY 185 BT QSY 250 and BT QSY 300 PCS QSY ADP** PCS QSY ADP** QSY EX** QSY EX** NOT USED PCS QSY ADP ADAPTER NOT USED **Not supplied QUICK BTQSYSeries INSTALLATION AND USER’S MANUAL - REV001B...
  • Page 14 Electrical connection Electrical connection BT QSY 140 and BT QSY 185 BT QSY 250 and BT QSY 300 Connection Connection NOT USED ADAPTER NOT USED **Common negative for battery groups. ***Not supplied QUICK BTQSYSeries INSTALLATION AND USER’S MANUAL - REV001B...
  • Page 15: Important Cautions

    • This thruster is not designed for continuous use. It is equipped with protections which limit its operation at a maximum time span, as reported on the controls’ manual. It is strongly forbidden to bypass or modify such protections in order to increase the operating time span, lest voiding the warranty and thus lifting any responsibility from Quick SPA.
  • Page 16: Product Disposal

    Separate the products for disposal in accordance with the regulations in force in your area or return the product to the seller when purchasing a new equivalent product. Local regulations may impose severe penalties for the improper disposal of this product. QUICK BTQSYSeries INSTALLATION AND USER’S MANUAL - REV001B...
  • Page 17: Spare Parts

    BTQSY 140-45 BTQSY 185-85 BTQSY 185-100 No. DESCRIPTION CODES OSP PROPELLER D140 RH QUICK 5 BLADES BLACK FVSGEL140R05A00 OSP COUPLING KIT 140 30/40KG S FVSGG141114SA00 OSP PROPELLER D185 LH QUICK 5 BLADES BLACK FVSGEL185L05A00 OSP COUPLING KIT BTQ 185 FVSGG1851414A00...
  • Page 18 BTQSY 250-140 BTQSY 250-200 BTQSY 300-240 BTQSY 300-300 No. DESCRIPTION CODES OSP PROPELLER D250 RH QUICK 5 BLADES BLACK FVSGEL250R05A00 OSP COUPLING KIT BTQ 250 FVSGG2501919A00 OSP PROPELLER D250 LH QUICK 5 BLADES BLACK FVSGEL250L05A00 OSP COUPLING KIT BTQ 300 FVSGG3000048A00...
  • Page 19 373 (14" 11/16) 373 (14" 11/16) 411 (16" 3/16) 250 (9" 13/16) 250 (9" 13/16) 300 (11" 13/16) 300 (11" 13/16) 372 (14" 5/8) 372 (14" 5/8) 434 (17" 1/16) 434 (17" 1/16) QUICK BTQSYSeries INSTALLATION AND USER’S MANUAL - REV001B...
  • Page 20 BT QSY Series REV 001B BT QSY 140 BT QSY 185 BT QSY 250 BT QSY 300 Product serial number QUICK S.p.A. - Via Piangipane, 120/A - 48124 Piangipane (RAVENNA) - ITALY ® Tel. +39.0544.415061 - Fax +39.0544.415047 - www.quickitaly.com - quick@quickitaly.com...