CXS Inlet Pressure Transmitter
Description
Item Number
Inlet Pressure Transmitter
M528-09-200

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M528-09-200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Edwards M528-09-200

  • Page 1 M528-09-840 Issue A Original Instruction Manual CXS Inlet Pressure Transmitter Description Item Number Inlet Pressure Transmitter M528-09-200...
  • Page 2 This page has been intentionally left blank.
  • Page 3: Table Of Contents

    Technical Information (Endress+Hauser Instruments International) Cerabar M PMC51, PMP51, PMP55 TI00436P/00/EN/15.11 No. 71134874) Trademark credits ® Loctite is a registered trademark of Henkel Corporation © Edwards Limited 2013. All rights reserved. Page i Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 4 M528-09-840 Issue A This page has been intentionally left blank. Page ii © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 5: Introduction

    Introduction Scope and definitions This manual provides installation, operation and maintenance instructions for the Edwards inlet pressure transmitter accessory. The inlet pressure transmitter must be used as specified in this manual. Read this manual before installing and operating the transmitter.
  • Page 6: Pressure Transmitter Recommended Locations (Cxs Dry Pumps With And Without Flame Arrestors)

    The cable connects the pressure transmitter to the interface connector block within the CXS control box. Figure 2 - CXS control box and interface connector block 1. Cable tray Page 2 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 7: Installation

    Personal protective equipment should be checked and used as specified by its supplier. Hazardous chemicals that have been pumped are located within the pumps and piping. Edwards recommends the use of suitable protective gloves and clothing along with a respirator if contact with substances is anticipated.
  • Page 8: Inlet Pressure Transmitter Installation

    0.2-0.25 Nm. Check that the connection is secure after tightening. The terminal blocks can be removed for ease of wiring. Firmly plug back into place. Page 4 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 9: Pressure Transmitter Electrical Connections Showing Terminals T1 And T2

    18. Perform a leak test before operating the pump. Figure 4 - Pressure transmitter electrical connections showing terminals T1 and T2 External grounding terminal Terminals © Edwards Limited 2013. All rights reserved. Page 5 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 10: Cable Installation Routing Recommendation (No Flame Arrestor)

    M528-09-840 Issue A Figure 5a - Cable installation routing recommendation (no flame arrestor) Figure 5b - Cable installation routing recommendation (with flame arrestor) Page 6 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 11: Pressure Transmitter Set-Up

    5. To exit the menu press the 'cancel' key three times where the light will revert to normal. © Edwards Limited 2013. All rights reserved. Page 7 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 12: Operation

    M528-09-840 Issue A Operation Inlet pressure display Inlet pressure is automatically displayed on a PDT (if fitted) after correct setup. Page 8 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 13: Maintenance

    The wiring should be checked at regular intervals. If damage is found it should be rectified immediately. Refer to the manufacturers instruction manual for maintenance of the inlet pressure transmitter. © Edwards Limited 2013. All rights reserved. Page 9 Edwards and the Edwards logo are trademarks of Edwards Limited.