  • Page 1 Automatic B arri er Maximum span - 7.0 Made in 100 % Duty cycle...
  • Page 2: Table Of Contents

    Index 3250 1. Inductions and warnings Page 03 2. Delivery, Movement and transport Page 04 3. General layout Page 05 4. Foundation Layout Drawing Page 06 6. Guide to Physical installation Page 07 -09 7. Commissioning Certificate Page 10 8. Manual release Page 11 9.
  • Page 3: Inductions And Warnings

    Introduction and Warnings 3250 This equipment is part of a large range of traffic flow products. They are designed to be easy to install, as all settings and internal wiring have been completed in our factory. Any of the instructions in this manual should only be carried out by a qualified service engineer or a competent person.
  • Page 4: Delivery, Movement And Transport

    3250 Transport and Handling. This article describes how your equipment will be delivered to you, specifications on the transportation used and advice including health & safety on movement of the equipment. The manufacturer will use a qualified transport company to deliver the product conforming to the necessary regulations as detailed below: ? All drivers are qualified ? All drivers are tested once yearly ( If applicable )
  • Page 5: General Layout

    General Layout. 3250 Shown below is a typical installation of a D3250 Automatic barrier for a single entrance. Control - Dual height Card access entry, Loop safety/lower with Auto loop exit. D210 Dual height access post D3250 Automatic Barrier Safety/Lower Loop...
  • Page 6: Foundation Layout Drawing

    3250 General Layout Foundation drawing.
  • Page 7: Guide To Physical Installation

    Guide to Physical Installation. 3250 Component Identification and Notes: You should check that you have received the following in your order as they are referred to throughout this manual (note this can change per barrier spec i.e. manual components are different from automatic): Box of bits C/w 4 x M16 parabolts O and M manual...
  • Page 8 Guide to Physical Installation. (Cont) 3250 Remove Both Barrier covers using the keys provided Now make sure all cables are through the duct and And place the Covers somewhere safe to prevent them Routed where they need to go (e.g mains cable to getting damaged.
  • Page 9 3250 Guide to Physical Installation. (Cont) epending on pole length you may now be required Now connect all Induction loops, Mains power and To adjust the limit switches if the pole is not finishing In the Any other accessories you have using the desired position.
  • Page 10: Commissioning Certificate

    3250 Commissioning Certificate. We certify that the system covered by this certificate has been commissioned satisfactorily. Site Name Completion Site Reference Engineers Installing Installation Commenced Commissioning Equipment Fitted Handover Date Part 2. Existing Installation Items not covered under warranty/ This certificate: Part 3.
  • Page 11: Manual Release

    3250 Manual Release. Electrical T roubleshooting Guide Please use the following instructions to operate the barrier manually, the following is assuming you have powered down the unit. To Manually release the barrier please remove the cover using key supplied, then take the release Handle ( which will be handed over with the keys ) and insert into the motor and rotate.
  • Page 12: Terminal Connections

    3250 Connection Terminals When used as a Master Barrier below terminals will be situated on the din rail 16 - Connect to terminal 4 in slave barrier 17 - Connect to terminal 5 in slave barrier 18 - Connect to terminal 4 in slave barrier 19 - Connect to terminal 3 in slave barrier...
  • Page 13: Control Panel Layout

    3250 Control Panel layout. Inverter 24VDC Power supply Programming screen 24v Fuse 1Amp 240v Breaker Loop Detector Low voltage terminals 240v Terminals Above shows a typical barrier control panel layout which identifies the major components...
  • Page 14: Using The Controller Display

    To access operator interface to Operate and change parameters Of the barrier. Select Alarm Once you select operator interface D3250 Main Menu You will see the screen shown in Parameters The left diagram which shows Time Clocks Settings you can alter. One very...
  • Page 15: Barrier Parameters

    3250 Barrier parameters Below is a table of all the parameters available to set in the barriers PLC, Please note there may be Bespoke programs developed for certain companies where the parameters may be differ from below. Barrier parameters Description Default This turns on a timer that times out and lowers No Pass Timer...
  • Page 16: Barrier Timers

    Within the barriers plc screen you can set up various timers. Follow the below instructions to set up. Accessing Timers To access the timers scroll down D3250 Main Menu To Timers and press ok, here you Parameters Time Clocks Will see a list of timers that you...
  • Page 17: Barrier Time Clock

    Function 2 - Auto Timeclock which disables the auto loop Note, you will need to turn these timers on in parameters once you have set up them up as below. Using the Arrows/dial navigate the D3250 Main Menu Cursor to operator interface and Parameters Time Clocks...
  • Page 18: Fault Finding

    3250 Electrical Troubleshooting guide. The table (bottom) relates to the diagram directly below to help you trouble shoot electrical component errors The image on the left shows the input and output LED indicators, use these with the chart below EROR To identify any faults with the barrier.
  • Page 19 3250 Troubleshooting guide. (Cont.) MECHANICAL ERRORS CAUSE CORRECTION Barrier arm keeps going up and down Limit switch fault check and reset limit switches Barrier creaking when moving Check bearings Oil or grease bearings Barrier motor not running Loss of voltage Check motor supply test 3 phases Barrier not raising or lowering Possible stripped gears...
  • Page 20: Barrier Maintenance

    3250 Barrier Maintenance As stated at the beginning of this manual we recommend a bi-annual service, but at a bare minimum, it is imperative that you get a service done once every 12 months. This is not a sales tactic in disguise, there is a very serious health and safety issue/risk associated with not complying to this.
  • Page 21: Service Log

    3250 Service Log. This Manual must be completed in accordance with the guidelines below, at any point service/repair work is carried out on the product. This is to achieve two things; 1. To keep a history of the product for yourself and your supplier/manufacturer. 2.
  • Page 22: Technical Data

    3250 Technical data. Specification Maximum Boom Length: metres Power Requirement: 230v, Single Phase, 50Hz, 5 Amps Drive Motor: 3 Phase motor & wormed gearbox Opening/Closing time: - 7.0 seconds Duty Cycle: 100% continuos duty rating Operation Time: Seconds per metre (Variable) Finish: Polyester Powder Coated Dimensions:...