Download Print this page

Hargrove JCA-PO Installation Manual page 2

Vented gas logs manual on/off gas valve

Advertisement

NOTE: THIS KIT IS FOR USE WITH NATURAL GAS. ALL PROPANE SETS MUST HAVE A
SAFETY PILOT CONTROL KIT AND A PROPANE CONVERSION KIT.
PART NUMBER
N-6X2.5
PRB 8-6
48-6
BVA
BVA 3 KEY
Check that the gas is turned off.
The gas supply line should be ½" inside diameter (ID) up to 30 feet and ¾" for longer distance.
Attach the N-6X2.5 to the end of the Ember Burner Pan.
Attach the PRB 8-6 to the end of the N-6X2.5.
Attach the BVA Valve to the PRB 8-6 with the external threading and the key slot facing the front
of the burner.
Connect the PBB 8-6 to the back of the BVA Valve and insert the 18-6 in the PRB 8-6
Connect to gas supply.
Insert the key into the key slot.
NOTE: When lighting burner, always have flame present before turning on the flow of gas.
PARTS LIST
PRB 8-6
Ember Burner
N-6X2.5
DESCRIPTION
3/8" DIA. 2.5" LONG PIPE NIPPLE
3/8" TO ½" FITTING
3/8" MIP X 3/8" FL BRASS FITTING
MANUAL VALVE
3 INCH KEY
GAS CONNECTION
48-6
BVA
BVA 3 KEY

Advertisement

loading